語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Study of particle formation using su...
~
Chang, Alan An-Lei.
FindBook
Google Book
Amazon
博客來
Study of particle formation using supercritical carbon dioxide as an antisolvent.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Study of particle formation using supercritical carbon dioxide as an antisolvent./
作者:
Chang, Alan An-Lei.
面頁冊數:
209 p.
附註:
Adviser: Ruben G. Carbonell.
Contained By:
Dissertation Abstracts International68-06B.
標題:
Chemistry, Pharmaceutical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3269367
ISBN:
9780549076315
Study of particle formation using supercritical carbon dioxide as an antisolvent.
Chang, Alan An-Lei.
Study of particle formation using supercritical carbon dioxide as an antisolvent.
- 209 p.
Adviser: Ruben G. Carbonell.
Thesis (Ph.D.)--North Carolina State University, 2007.
Particle design using supercritical CO2 has been of great interest in the pharmaceutical, microelectronic, catalytic, and related industries over the past 10 years. There have been numerous papers and patents published on the processes studied in this work. The solubility of most drug compounds in carbon dioxide is very low, making it a very attractive antisolvent for particle formation at suitable ranges of temperatures and pressures. This dissertation explores the use of different CO2 antisolvent precipitation system designs for the formulation of small crystalline drug particles of a given size, morphology, and uniformity, using the precipitation of acetaminophen from ethanol as an example.
ISBN: 9780549076315Subjects--Topical Terms:
550957
Chemistry, Pharmaceutical.
Study of particle formation using supercritical carbon dioxide as an antisolvent.
LDR
:05618nam 2200337 a 45
001
958173
005
20110704
008
110704s2007 ||||||||||||||||| ||eng d
020
$a
9780549076315
035
$a
(UMI)AAI3269367
035
$a
AAI3269367
040
$a
UMI
$c
UMI
100
1
$a
Chang, Alan An-Lei.
$3
1281634
245
1 0
$a
Study of particle formation using supercritical carbon dioxide as an antisolvent.
300
$a
209 p.
500
$a
Adviser: Ruben G. Carbonell.
500
$a
Source: Dissertation Abstracts International, Volume: 68-06, Section: B, page: 3954.
502
$a
Thesis (Ph.D.)--North Carolina State University, 2007.
520
$a
Particle design using supercritical CO2 has been of great interest in the pharmaceutical, microelectronic, catalytic, and related industries over the past 10 years. There have been numerous papers and patents published on the processes studied in this work. The solubility of most drug compounds in carbon dioxide is very low, making it a very attractive antisolvent for particle formation at suitable ranges of temperatures and pressures. This dissertation explores the use of different CO2 antisolvent precipitation system designs for the formulation of small crystalline drug particles of a given size, morphology, and uniformity, using the precipitation of acetaminophen from ethanol as an example.
520
$a
In order to understand the precipitation process, the equilibrium concentration of acetaminophen in CO2 and CO2 plus ethanol were measured at a range of temperatures and pressures in a high-pressure extraction system. This information is important in understanding the supersaturation of the drug at various precipitation conditions.
520
$a
Several antisolvent processes were tested in order to determine their effectiveness in controlling the precipitation of acetaminophen from ethanol. The first system involved the use of solution enhanced dispersion by supercritical fluid (SEDS) patented by Hanna and York (WO9501221, 1994). This process uses a coaxial nozzle design where the solvent with the solute of interest is injected in the inner tube and the supercritical CO2 is injected in the outer tube. The two streams mix at nearly constant pressure and temperature in a small volume region of the nozzle before exiting through the nozzle tip into a chamber maintained at a fixed temperature and pressure. The fast mixing process rapidly expands the solvent with CO2 in order to induce phase split of the solid drug particles. The chamber pressure is maintained constant and nearly equal to the pressure in the nozzle.
520
$a
This process was studied because it was claimed that SEDS gave the best control of system parameters. However, the thermodynamic, hydrodynamic and kinetic mechanisms resulting in particle formation are still not well understood. The effects of the nozzle and vessel dimensions on system performance had not been studied previously. In addition, little work has been published on the effects of variables such as liquid solvent and CO2 flow rates, solute concentration, temperature, and pressure on particle size and morphology.
520
$a
A design of experiments (DOE) analysis was used to identify the more important process parameters that control particle size and morphology at the early stages of experimentation. With DOE, a 512 full factorial run was reduced to 32 runs by confounding primary variables with higher order interactions (Example: concentration + solution flow rate). The results of these experiments indicated that the most important factors in determining particle size and morphology are the concentration of acetaminophen in the solvent, the nozzle geometry (length of the mixing zone), and solution flow rate. These parameters were singled out for more detailed experiments aimed at determining the influence of these variables on particle size and morphology. A key feature of the experiments described in this dissertation is the use of online monitoring of the acetaminophen concentration at the exit to the capture vessel in order to determine how the supersaturation of the solute varied with time during the process. In this way, it was possible to determine the nozzle effectiveness in particle precipitation.
520
$a
In addition, the experiment performed in this dissertation recognized that the SEDS process is in essence a batch process and the effect of transients in co-solvent concentrations in the particle capture vessel on particle size and morphology were studied. In addition to SEDS, the precipitation of acetaminophen from ethanol was carried out using a precipitation with compressed antisolvent (PCA) process, which is very similar to SEDS without the coaxial configuration. This system is simple to install and has been widely studied. The parameters that were important from the SEDS experiments were studied in the PCA to characterize their effects on particle size and morphology for this system. These results were compared to those obtained using the SEDS process. Both SEDS and PCA yielded equal particle size and morphology if designed properly. The major feature of this work was the emphasis on the design of an effective nozzle for the PCA application. Similar to the SEDS results, a good mixing volume along with adequate residence time for micromixing is the best nozzle design.
590
$a
School code: 0155.
650
4
$a
Chemistry, Pharmaceutical.
$3
550957
650
4
$a
Engineering, Chemical.
$3
1018531
690
$a
0491
690
$a
0542
710
2
$a
North Carolina State University.
$3
1018772
773
0
$t
Dissertation Abstracts International
$g
68-06B.
790
$a
0155
790
1 0
$a
Carbonell, Ruben G.,
$e
advisor
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3269367
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9121638
電子資源
11.線上閱覽_V
電子書
EB W9121638
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入