語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
The Power of Synchrophasors: Electri...
~
Konakalla, Sai Akhil Reddy.
FindBook
Google Book
Amazon
博客來
The Power of Synchrophasors: Electric Grid Monitoring, Control and Optimization.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
The Power of Synchrophasors: Electric Grid Monitoring, Control and Optimization./
作者:
Konakalla, Sai Akhil Reddy.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2019,
面頁冊數:
178 p.
附註:
Source: Dissertations Abstracts International, Volume: 80-10, Section: B.
Contained By:
Dissertations Abstracts International80-10B.
標題:
Mechanics. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13421477
ISBN:
9781392020296
The Power of Synchrophasors: Electric Grid Monitoring, Control and Optimization.
Konakalla, Sai Akhil Reddy.
The Power of Synchrophasors: Electric Grid Monitoring, Control and Optimization.
- Ann Arbor : ProQuest Dissertations & Theses, 2019 - 178 p.
Source: Dissertations Abstracts International, Volume: 80-10, Section: B.
Thesis (Ph.D.)--University of California, San Diego, 2019.
This item must not be sold to any third party vendors.
Recent growth in deployment of distributed energy resources (DERs), energy storage systems, and advanced grid control schemes have increased the levels of variability in generation and load conditions over the electric transmission and distribution system. Microgrids are distribution level power systems that operate as a single controllable system in a grid connected or islanded (disconnected) mode. The balance between supply and demand of power is one of the most important requirements of microgrid management. The ability to control such a system hence becomes a very important task in order to stably and smoothly operate the microgrid. One such elegant method to overcome these challenges is the use of the phasor measurement units (PMUs) for wide-area distributed networks capable of measuring time-synchronized phasor (synchrophasor) data at high rates in the multiples of the main AC frequency (up to 240 Hz for a 60 Hz signal). The importance to use synchrophasors for this application is two-fold: Firstly, the ability for high frequency and synchronized sampling significantly enhances (transient) grid monitoring and also improves performance of the state estimation or (recursive) prediction that can be used for real-time control. Secondly, synchrophasor measurements can be used to coordinate the power exchange between cooperative multiple loads (microgrids) using the time-synchronized measurements. However, due to the high sampling rates of synchrophasor data, it becomes an unwieldy task to process such huge data from multiple locations. Local (signal) processing of PMU data to detect, store and classify events in the electric grid at the point of measurement is one of the main contributions of the dissertation. To address the demand and supply problem in a microgrid, (recursive) demand prediction and (optimal) generation dispatch techniques using synchrophasors are discussed in the dissertation. In order to design high speed control algorithms for such microgrid systems, derivation of a system model via system identification using data driven techniques would be more convenient than derivation via swing equations. Hence, the dissertation contributes in the estimation of a low order linear time invariant (LTI) model for active and reactive power flow (derived from the PMUs) through the microgrid. Using the derived models, it is shown how real-time PMU measurements can further be used in the islanding (power flow and angle) control of microgrids. Finally, robustness of missing PMU data for control applications is addressed in the dissertation.
ISBN: 9781392020296Subjects--Topical Terms:
525881
Mechanics.
Subjects--Index Terms:
Distributed energy resources
The Power of Synchrophasors: Electric Grid Monitoring, Control and Optimization.
LDR
:03790nmm a2200361 4500
001
2267737
005
20200821052153.5
008
220629s2019 ||||||||||||||||| ||eng d
020
$a
9781392020296
035
$a
(MiAaPQ)AAI13421477
035
$a
(MiAaPQ)ucsd:18050
035
$a
AAI13421477
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Konakalla, Sai Akhil Reddy.
$3
3545001
245
1 4
$a
The Power of Synchrophasors: Electric Grid Monitoring, Control and Optimization.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
178 p.
500
$a
Source: Dissertations Abstracts International, Volume: 80-10, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: de Callafon, Raymond A.
502
$a
Thesis (Ph.D.)--University of California, San Diego, 2019.
506
$a
This item must not be sold to any third party vendors.
520
$a
Recent growth in deployment of distributed energy resources (DERs), energy storage systems, and advanced grid control schemes have increased the levels of variability in generation and load conditions over the electric transmission and distribution system. Microgrids are distribution level power systems that operate as a single controllable system in a grid connected or islanded (disconnected) mode. The balance between supply and demand of power is one of the most important requirements of microgrid management. The ability to control such a system hence becomes a very important task in order to stably and smoothly operate the microgrid. One such elegant method to overcome these challenges is the use of the phasor measurement units (PMUs) for wide-area distributed networks capable of measuring time-synchronized phasor (synchrophasor) data at high rates in the multiples of the main AC frequency (up to 240 Hz for a 60 Hz signal). The importance to use synchrophasors for this application is two-fold: Firstly, the ability for high frequency and synchronized sampling significantly enhances (transient) grid monitoring and also improves performance of the state estimation or (recursive) prediction that can be used for real-time control. Secondly, synchrophasor measurements can be used to coordinate the power exchange between cooperative multiple loads (microgrids) using the time-synchronized measurements. However, due to the high sampling rates of synchrophasor data, it becomes an unwieldy task to process such huge data from multiple locations. Local (signal) processing of PMU data to detect, store and classify events in the electric grid at the point of measurement is one of the main contributions of the dissertation. To address the demand and supply problem in a microgrid, (recursive) demand prediction and (optimal) generation dispatch techniques using synchrophasors are discussed in the dissertation. In order to design high speed control algorithms for such microgrid systems, derivation of a system model via system identification using data driven techniques would be more convenient than derivation via swing equations. Hence, the dissertation contributes in the estimation of a low order linear time invariant (LTI) model for active and reactive power flow (derived from the PMUs) through the microgrid. Using the derived models, it is shown how real-time PMU measurements can further be used in the islanding (power flow and angle) control of microgrids. Finally, robustness of missing PMU data for control applications is addressed in the dissertation.
590
$a
School code: 0033.
650
4
$a
Mechanics.
$3
525881
650
4
$a
Mechanical engineering.
$3
649730
653
$a
Distributed energy resources
653
$a
Linear time invariant
653
$a
Microgrids
690
$a
0346
690
$a
0548
710
2
$a
University of California, San Diego.
$b
Mechanical and Aerospace Engineering.
$3
2096513
773
0
$t
Dissertations Abstracts International
$g
80-10B.
790
$a
0033
791
$a
Ph.D.
792
$a
2019
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13421477
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9419971
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入