語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
The effect of noise levels on transi...
~
Wendt-Harris, Barbara Lynn.
FindBook
Google Book
Amazon
博客來
The effect of noise levels on transient evoked otoacoustic emissions (TEOAE) measures.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
The effect of noise levels on transient evoked otoacoustic emissions (TEOAE) measures./
作者:
Wendt-Harris, Barbara Lynn.
面頁冊數:
109 p.
附註:
Source: Dissertation Abstracts International, Volume: 58-09, Section: B, page: 4701.
Contained By:
Dissertation Abstracts International58-09B.
標題:
Health Sciences, Audiology. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9807549
ISBN:
0591578484
The effect of noise levels on transient evoked otoacoustic emissions (TEOAE) measures.
Wendt-Harris, Barbara Lynn.
The effect of noise levels on transient evoked otoacoustic emissions (TEOAE) measures.
- 109 p.
Source: Dissertation Abstracts International, Volume: 58-09, Section: B, page: 4701.
Thesis (Ph.D.)--The University of Connecticut, 1997.
A systematic investigation of the effect of environmental noise on transient evoked otoacoustic emissions (TEOAE) measures was completed using the ILO 88 Otodynamics Analyzer with the Quickscreen option. Dependent variables included whole and bandlimited reprodudbility measures.
ISBN: 0591578484Subjects--Topical Terms:
1018138
Health Sciences, Audiology.
The effect of noise levels on transient evoked otoacoustic emissions (TEOAE) measures.
LDR
:03132nmm 2200349 4500
001
1852117
005
20051229080337.5
008
130614s1997 eng d
020
$a
0591578484
035
$a
(UnM)AAI9807549
035
$a
AAI9807549
040
$a
UnM
$c
UnM
100
1
$a
Wendt-Harris, Barbara Lynn.
$3
1939989
245
1 4
$a
The effect of noise levels on transient evoked otoacoustic emissions (TEOAE) measures.
300
$a
109 p.
500
$a
Source: Dissertation Abstracts International, Volume: 58-09, Section: B, page: 4701.
500
$a
Major Adviser: A. Maxon.
502
$a
Thesis (Ph.D.)--The University of Connecticut, 1997.
520
$a
A systematic investigation of the effect of environmental noise on transient evoked otoacoustic emissions (TEOAE) measures was completed using the ILO 88 Otodynamics Analyzer with the Quickscreen option. Dependent variables included whole and bandlimited reprodudbility measures.
520
$a
Repeated TEOAEs were collected on 26 adult subjects using four different noise types: white noise, broadband noise, one octave wide 500 Hz narrowband noise, and one octave wide 2000 Hz narrowband noise. Each noise was presented at eight intensity levels from 45 dBA to 75 dBA in 5 dB increments.
520
$a
Repeated measures analysis of variance results showed no significant effect of intensity level until 55 dBA to 65 dBA dependent on noise type used and reproducibility measure investigated.
520
$a
Narrowband noises had their greatest effect on the bandlimited reproducibilities which had similar frequency content. The one octave wide narrowband noise centered at 500 Hz affected whole reproducibility only. It did not affect any of the bandlimited reproducibilities presumably because its narrow frequency range did not spread energy into the bandlimited frequency bands.
520
$a
Ten infants were tested with a reduced set of criteria based on adult results. Infants were tested at levels beginning at 40 dBA. Testing continued at higher intensity levels until an acceptable TEOAE could not be obtained.
520
$a
Comparing infant to adult results using t-tests for the intensity range of 45 to 55 dBA, infants had significantly poorer 1600 Hz reproducibility scores with all noises, but significantly better 3200 Hz and 4000 Hz reproducibility scores with the narrowband noises. The greater noise generated by infants in the low frequencies and the greater emission amplitude of infants in the high frequencies are suspected to be responsible, in part, for this finding.
520
$a
It was noted that high levels of noise caused a state change in infants, arousing them into a state unsuitable for testing.
520
$a
Results suggest that for newborn hearing screening the criteria used to determine acceptable TEOAEs need to take into account level and frequency content of environmental noise present during testing.
590
$a
School code: 0056.
650
4
$a
Health Sciences, Audiology.
$3
1018138
690
$a
0300
710
2 0
$a
The University of Connecticut.
$3
1249323
773
0
$t
Dissertation Abstracts International
$g
58-09B.
790
1 0
$a
Maxon, A.,
$e
advisor
790
$a
0056
791
$a
Ph.D.
792
$a
1997
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9807549
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9201631
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入