Four-dimensional CT methods using low-pitch multi-slice helical acquisition.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Four-dimensional CT methods using low-pitch multi-slice helical acquisition./
作者:
Wink, Nicole Marie.
面頁冊數:
145 p.
附註:
Adviser: Timothy D. Solberg.
Contained By:
Dissertation Abstracts International67-07B.
標題:
Biophysics, Medical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3226049
ISBN:
9780542796777
Four-dimensional CT methods using low-pitch multi-slice helical acquisition.
Wink, Nicole Marie.
Four-dimensional CT methods using low-pitch multi-slice helical acquisition.
- 145 p.
Adviser: Timothy D. Solberg.
Thesis (Ph.D.)--University of California, Los Angeles, 2006.
Lung cancer is the leading cause of cancer death in the United States. Radiation therapy is indicated for 40% of the unresectable cases. Studies demonstrate improved local control and overall survival with an escalation in dose from conventional treatments, but care must be taken to spare healthy tissue. In order to increase target dose and decrease normal tissue irradiation, a clear representation of the target at all points of treatment must be obtained. Obtaining a clear image is difficult though, because images of the thorax and abdominal regions are subject to artifacts and distortions due to respiratory motion. Retrospective gating of CT image data based on a measured respiratory waveform (4D-CT) has proven to be a viable option to reduce the impact of respiratory motion on CT image quality. The goal of this project was to optimize the process of obtaining a multi-slice, helical 4D-CT image set. Four different breathing instruction techniques were evaluated using three respiration monitoring devices. A new retrospective sorting method was developed and compared to other published gating methods. Image quality was quantitatively assessed under variable reconstruction and scanning parameters. Among the recorded respiration traces, the most consistent period resulted from audible instruction, while no statistical difference between techniques was found for consistency in amplitude. The novel percentage amplitude sorting method was superior to the established time-based sorting methods in that it could accurately handle irregularities in period and slope of the respiration motion functions. Faster rotation speeds were optimal when assessing 4D-CT image quality, while no significant differences were observed with a change of pitch. Use of retrospective gating showed improvement in image quality parameters of objects in motion, providing more evidence towards the benefits of 4D-CT.
ISBN: 9780542796777Subjects--Topical Terms:
1017681
Biophysics, Medical.
Four-dimensional CT methods using low-pitch multi-slice helical acquisition.
LDR
:02816nam 2200277 a 45
001
970651
005
20110921
008
110921s2006 eng d
020
$a
9780542796777
035
$a
(UMI)AAI3226049
035
$a
AAI3226049
040
$a
UMI
$c
UMI
100
1
$a
Wink, Nicole Marie.
$3
1294689
245
1 0
$a
Four-dimensional CT methods using low-pitch multi-slice helical acquisition.
300
$a
145 p.
500
$a
Adviser: Timothy D. Solberg.
500
$a
Source: Dissertation Abstracts International, Volume: 67-07, Section: B, page: 3649.
502
$a
Thesis (Ph.D.)--University of California, Los Angeles, 2006.
520
$a
Lung cancer is the leading cause of cancer death in the United States. Radiation therapy is indicated for 40% of the unresectable cases. Studies demonstrate improved local control and overall survival with an escalation in dose from conventional treatments, but care must be taken to spare healthy tissue. In order to increase target dose and decrease normal tissue irradiation, a clear representation of the target at all points of treatment must be obtained. Obtaining a clear image is difficult though, because images of the thorax and abdominal regions are subject to artifacts and distortions due to respiratory motion. Retrospective gating of CT image data based on a measured respiratory waveform (4D-CT) has proven to be a viable option to reduce the impact of respiratory motion on CT image quality. The goal of this project was to optimize the process of obtaining a multi-slice, helical 4D-CT image set. Four different breathing instruction techniques were evaluated using three respiration monitoring devices. A new retrospective sorting method was developed and compared to other published gating methods. Image quality was quantitatively assessed under variable reconstruction and scanning parameters. Among the recorded respiration traces, the most consistent period resulted from audible instruction, while no statistical difference between techniques was found for consistency in amplitude. The novel percentage amplitude sorting method was superior to the established time-based sorting methods in that it could accurately handle irregularities in period and slope of the respiration motion functions. Faster rotation speeds were optimal when assessing 4D-CT image quality, while no significant differences were observed with a change of pitch. Use of retrospective gating showed improvement in image quality parameters of objects in motion, providing more evidence towards the benefits of 4D-CT.
590
$a
School code: 0031.
650
4
$a
Biophysics, Medical.
$3
1017681
650
4
$a
Health Sciences, Radiology.
$3
1019076
690
$a
0574
690
$a
0760
710
2 0
$a
University of California, Los Angeles.
$3
626622
773
0
$t
Dissertation Abstracts International
$g
67-07B.
790
$a
0031
790
1 0
$a
Solberg, Timothy D.,
$e
advisor
791
$a
Ph.D.
792
$a
2006
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3226049
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9129139
電子資源
11.線上閱覽_V
電子書
EB W9129139
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入