Circular reconstruction and scatter correction in X-ray cone-beam CT.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Circular reconstruction and scatter correction in X-ray cone-beam CT./
作者:
Zhu, Lei.
面頁冊數:
167 p.
附註:
Adviser: Rebecca Fahrig.
Contained By:
Dissertation Abstracts International68-02B.
標題:
Engineering, Electronics and Electrical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3253559
Circular reconstruction and scatter correction in X-ray cone-beam CT.
Zhu, Lei.
Circular reconstruction and scatter correction in X-ray cone-beam CT.
- 167 p.
Adviser: Rebecca Fahrig.
Thesis (Ph.D.)--Stanford University, 2007.
With the development of advanced computing and flat panel detector technology, volumetric X-ray computed tomography (CT) systems using large-area detectors, such as cone-beam CT (CBCT), are becoming more popular. This dissertation describes work aimed at reducing three types of image artifacts in CBCT.Subjects--Topical Terms:
626636
Engineering, Electronics and Electrical.
Circular reconstruction and scatter correction in X-ray cone-beam CT.
LDR
:03264nam 2200289 a 45
001
965665
005
20110906
008
110906s2007 eng d
035
$a
(UMI)AAI3253559
035
$a
AAI3253559
040
$a
UMI
$c
UMI
100
1
$a
Zhu, Lei.
$3
1288434
245
1 0
$a
Circular reconstruction and scatter correction in X-ray cone-beam CT.
300
$a
167 p.
500
$a
Adviser: Rebecca Fahrig.
500
$a
Source: Dissertation Abstracts International, Volume: 68-02, Section: B, page: 1210.
502
$a
Thesis (Ph.D.)--Stanford University, 2007.
520
$a
With the development of advanced computing and flat panel detector technology, volumetric X-ray computed tomography (CT) systems using large-area detectors, such as cone-beam CT (CBCT), are becoming more popular. This dissertation describes work aimed at reducing three types of image artifacts in CBCT.
520
$a
Artifacts appear in the reconstruction when insufficient projection data are measured or the data redundancy is not properly handled. In practical CBCT systems, the circular trajectory is commonly used due to the ease of implementation on existing hardware. However, due to Tuy's data sufficiency condition, an exact reconstruction is possible only in the plane of the source trajectory. In a circular full scan, the standard FDK algorithm has been shown to be close to the optimal if unmeasured data are assumed to be zero. This algorithm usually results in cone-beam (CB) artifacts in the reconstruction, such as the intensity drop along the axial direction. An algorithm is proposed for estimating the unmeasured data. The algorithm is derived from the Radon transform and Grangeat's formula. In a circular short scan (pi plus fan angle), the modified FDK algorithm using Parker's weighting is commonly used. This algorithm handles data redundancy using approximation. Besides the axial intensity drop, the algorithm results in another type of CB artifact, mainly streaks around dense objects. An improved algorithm is derived using the central slice theorem and geometry transformation. Both the proposed full-scan and short-scan algorithms are verified using computer simulations and physical experiments.
520
$a
Even if sufficient data are acquired and exact reconstruction is used, the projection data are corrupted by detected scatter, and cupping and shading artifacts appear in the reconstruction. Scatter is a large problem in CBCT systems since the geometry with a large-area detector has high scatter-to-primary ratios (SPR's). A scatter correction algorithm is introduced that provides effective scatter correction but does not require additional patient exposure. The algorithm uses a hardware-based modulation technique to separate scatter signal from the primary signal. The performance of this method is evaluated using computer simulations and preliminary physical experiments. With no loss of resolution, substantial reduction of scatter artifacts is shown using this approach.
590
$a
School code: 0212.
650
4
$a
Engineering, Electronics and Electrical.
$3
626636
650
4
$a
Health Sciences, Radiology.
$3
1019076
690
$a
0544
690
$a
0574
710
2 0
$a
Stanford University.
$3
754827
773
0
$t
Dissertation Abstracts International
$g
68-02B.
790
$a
0212
790
1 0
$a
Fahrig, Rebecca,
$e
advisor
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3253559
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9125266
電子資源
11.線上閱覽_V
電子書
EB W9125266
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入