語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
The effects of cyclic fatigue and ag...
~
Lin, Lihong.
FindBook
Google Book
Amazon
博客來
The effects of cyclic fatigue and aging on the fracture toughness of dental composites.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
The effects of cyclic fatigue and aging on the fracture toughness of dental composites./
作者:
Lin, Lihong.
面頁冊數:
151 p.
附註:
Source: Masters Abstracts International, Volume: 46-05, page: 2819.
Contained By:
Masters Abstracts International46-05.
標題:
Engineering, Materials Science. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1452395
ISBN:
9780549495819
The effects of cyclic fatigue and aging on the fracture toughness of dental composites.
Lin, Lihong.
The effects of cyclic fatigue and aging on the fracture toughness of dental composites.
- 151 p.
Source: Masters Abstracts International, Volume: 46-05, page: 2819.
Thesis (M.S.)--University of Illinois at Chicago, 2008.
Objective. The objective of this study was to examine the fracture toughness (KIC) of three direct dental composites, including one micro-filled (MicronewRTM, Bisco INC., Schaumburg, IL, USA), one hybrid (RenewRTM, Bisco INC., Schaumburg, IL, USA), and one nano-filled composite (Filtek(TM) Supreme Plus, 3M ESPE, St. Paul, MN, USA) and one indirect dental composite (BellGlass HP, SDS-Kerr, Orange, CA, USA), after aging and cyclic loading fatigue in four different environments, namely, air, water, a 50/50 by volume mixture of ethanol and water, and artificial saliva. Methods. The rectangular bar specimens were fabricated and a 60 degree notch was machined at the midspan of each bar. Aging group specimens were aged at 37°C for five months in air, artificial saliva, water, and a 50/50 by volume mixture of ethanol and water. The specimens were loaded in each corresponding media at a frequency of 5 Hz with sinusoidal loads cycling between 5 N and 10 N for 1, 1000, 10,000 and 100,000 cycles. Following cyclic loading, the specimens were tested in three-point loading in their respective media. Results . BellGlass HP displayed overall the best mechanical properties, followed by RenewRTM and Filtek(TM) Supreme Plus. Micronew RTM had the worst performance of the four composite materials investigated in this study. The non-aged group of Filtek(TM) Supreme Plus showed a strikingly similar performance to RenewRTM, a hybrid composite, both in the number of cycles completed and in the fracture toughness in all testing conditions. Aged Filtek Supreme Plus however, showed increased failure during cyclic fatigue loading, and also showed significantly decreased fracture toughness when compared to RenewRTM. Media did not have a significant effect on the number of cycles completed and the fracture toughness in the control group of BellGlass HP, Filtek(TM) Supreme Plus, and Renew RTM specimens. For MicronewRTM, air was the media which had the most detrimental effect on fracture toughness and the number of cycles completed in all four media investigated. For the aged groups, none of BellGlass HP specimens fractured during cyclic loading in all four media; for the remaining three materials, the 50/50 mixture was the most detrimental one on fracture toughness and the number of cycles completed in all four media investigated. Aging had the most detrimental effect on Filtek(TM) Supreme Plus and MicronewRTM. In terms of the effect of cyclic fatigue, there were no significant differences on the number of cycles completed and fracture toughness as the predetermined set of cycle numbers increased in the control group of BellGlass HP, Filtek(TM) Supreme Plus, and Renew RTM. For MicronewRTM, there was an increased specimen failure rate and decreased fracture toughness as the predetermined set of cycle numbers increased. In the aged groups, cyclic fatigue did not have a significant effect on BelleGlass HP and Filtek(TM) Supreme Plus in water and artificial saliva, and RenewRTM in terms of both fracture toughness and the number of cycles completed, except for RenewRTM in the 50/50 mixture at 100,000 cycles. For Filtek(TM) Supreme Plus in air and the 50/50 mixture and MicronewRTM, there was an increased specimen failure rate and a decreased fracture toughness during cyclic fatigue loading as the predetermined set of cycles increased. BellGlass HP displayed overall the best mechanical properties, followed by RenewRTM and Filtek(TM) Supreme Plus. Micronew RTM had the worst performance of the four composite materials investigated in this study.
ISBN: 9780549495819Subjects--Topical Terms:
1017759
Engineering, Materials Science.
The effects of cyclic fatigue and aging on the fracture toughness of dental composites.
LDR
:04366nam 2200253 a 45
001
958896
005
20110704
008
110704s2008 ||||||||||||||||| ||eng d
020
$a
9780549495819
035
$a
(UMI)AAI1452395
035
$a
AAI1452395
040
$a
UMI
$c
UMI
100
1
$a
Lin, Lihong.
$3
1282359
245
1 4
$a
The effects of cyclic fatigue and aging on the fracture toughness of dental composites.
300
$a
151 p.
500
$a
Source: Masters Abstracts International, Volume: 46-05, page: 2819.
502
$a
Thesis (M.S.)--University of Illinois at Chicago, 2008.
520
$a
Objective. The objective of this study was to examine the fracture toughness (KIC) of three direct dental composites, including one micro-filled (MicronewRTM, Bisco INC., Schaumburg, IL, USA), one hybrid (RenewRTM, Bisco INC., Schaumburg, IL, USA), and one nano-filled composite (Filtek(TM) Supreme Plus, 3M ESPE, St. Paul, MN, USA) and one indirect dental composite (BellGlass HP, SDS-Kerr, Orange, CA, USA), after aging and cyclic loading fatigue in four different environments, namely, air, water, a 50/50 by volume mixture of ethanol and water, and artificial saliva. Methods. The rectangular bar specimens were fabricated and a 60 degree notch was machined at the midspan of each bar. Aging group specimens were aged at 37°C for five months in air, artificial saliva, water, and a 50/50 by volume mixture of ethanol and water. The specimens were loaded in each corresponding media at a frequency of 5 Hz with sinusoidal loads cycling between 5 N and 10 N for 1, 1000, 10,000 and 100,000 cycles. Following cyclic loading, the specimens were tested in three-point loading in their respective media. Results . BellGlass HP displayed overall the best mechanical properties, followed by RenewRTM and Filtek(TM) Supreme Plus. Micronew RTM had the worst performance of the four composite materials investigated in this study. The non-aged group of Filtek(TM) Supreme Plus showed a strikingly similar performance to RenewRTM, a hybrid composite, both in the number of cycles completed and in the fracture toughness in all testing conditions. Aged Filtek Supreme Plus however, showed increased failure during cyclic fatigue loading, and also showed significantly decreased fracture toughness when compared to RenewRTM. Media did not have a significant effect on the number of cycles completed and the fracture toughness in the control group of BellGlass HP, Filtek(TM) Supreme Plus, and Renew RTM specimens. For MicronewRTM, air was the media which had the most detrimental effect on fracture toughness and the number of cycles completed in all four media investigated. For the aged groups, none of BellGlass HP specimens fractured during cyclic loading in all four media; for the remaining three materials, the 50/50 mixture was the most detrimental one on fracture toughness and the number of cycles completed in all four media investigated. Aging had the most detrimental effect on Filtek(TM) Supreme Plus and MicronewRTM. In terms of the effect of cyclic fatigue, there were no significant differences on the number of cycles completed and fracture toughness as the predetermined set of cycle numbers increased in the control group of BellGlass HP, Filtek(TM) Supreme Plus, and Renew RTM. For MicronewRTM, there was an increased specimen failure rate and decreased fracture toughness as the predetermined set of cycle numbers increased. In the aged groups, cyclic fatigue did not have a significant effect on BelleGlass HP and Filtek(TM) Supreme Plus in water and artificial saliva, and RenewRTM in terms of both fracture toughness and the number of cycles completed, except for RenewRTM in the 50/50 mixture at 100,000 cycles. For Filtek(TM) Supreme Plus in air and the 50/50 mixture and MicronewRTM, there was an increased specimen failure rate and a decreased fracture toughness during cyclic fatigue loading as the predetermined set of cycles increased. BellGlass HP displayed overall the best mechanical properties, followed by RenewRTM and Filtek(TM) Supreme Plus. Micronew RTM had the worst performance of the four composite materials investigated in this study.
590
$a
School code: 0799.
650
4
$a
Engineering, Materials Science.
$3
1017759
650
4
$a
Health Sciences, Dentistry.
$3
1019378
690
$a
0567
690
$a
0794
710
2
$a
University of Illinois at Chicago.
$3
1020478
773
0
$t
Masters Abstracts International
$g
46-05.
790
$a
0799
791
$a
M.S.
792
$a
2008
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1452395
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9122361
電子資源
11.線上閱覽_V
電子書
EB W9122361
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入