語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Improving geometric accuracy in radi...
~
Boswell, Sarah Ann.
FindBook
Google Book
Amazon
博客來
Improving geometric accuracy in radiation delivery using helical tomotherapy.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Improving geometric accuracy in radiation delivery using helical tomotherapy./
作者:
Boswell, Sarah Ann.
面頁冊數:
160 p.
附註:
Adviser: Thomas Rockwell Mackie.
Contained By:
Dissertation Abstracts International67-09B.
標題:
Biophysics, Medical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3234553
ISBN:
9780542883125
Improving geometric accuracy in radiation delivery using helical tomotherapy.
Boswell, Sarah Ann.
Improving geometric accuracy in radiation delivery using helical tomotherapy.
- 160 p.
Adviser: Thomas Rockwell Mackie.
Thesis (Ph.D.)--The University of Wisconsin - Madison, 2006.
Highly conformal radiation delivery demands very accurate target localization at each treatment fraction. The daily goal is to match the optimized treatment plan as closely as possible. Refining the initial setup to the room lasers depends equally on accurately determining any setup errors and correcting for them. If the patient anatomy is deformable and the registration/correction methods are limited to rigid-body adjustments, setup verification involves subjective, priority-based decisions. Having determined the needed adjustments, re-positioning the patient can be an error-prone process that may necessitate further setup verification; thus, it is more accurate to make adjustments to the couch or otherwise modify the delivery, with minimal disruption to the patient. The entire process must also be conducted quickly in order to maintain accuracy.
ISBN: 9780542883125Subjects--Topical Terms:
1017681
Biophysics, Medical.
Improving geometric accuracy in radiation delivery using helical tomotherapy.
LDR
:03394nam 2200301 a 45
001
958500
005
20110704
008
110704s2006 eng d
020
$a
9780542883125
035
$a
(UMI)AAI3234553
035
$a
AAI3234553
040
$a
UMI
$c
UMI
100
1
$a
Boswell, Sarah Ann.
$3
1281961
245
1 0
$a
Improving geometric accuracy in radiation delivery using helical tomotherapy.
300
$a
160 p.
500
$a
Adviser: Thomas Rockwell Mackie.
500
$a
Source: Dissertation Abstracts International, Volume: 67-09, Section: B, page: 4923.
502
$a
Thesis (Ph.D.)--The University of Wisconsin - Madison, 2006.
520
$a
Highly conformal radiation delivery demands very accurate target localization at each treatment fraction. The daily goal is to match the optimized treatment plan as closely as possible. Refining the initial setup to the room lasers depends equally on accurately determining any setup errors and correcting for them. If the patient anatomy is deformable and the registration/correction methods are limited to rigid-body adjustments, setup verification involves subjective, priority-based decisions. Having determined the needed adjustments, re-positioning the patient can be an error-prone process that may necessitate further setup verification; thus, it is more accurate to make adjustments to the couch or otherwise modify the delivery, with minimal disruption to the patient. The entire process must also be conducted quickly in order to maintain accuracy.
520
$a
Helical tomotherapy is a rotational IMRT modality with CT scanning capabilities. Tomotherapy's unique helical scanning geometry has opened the way for new strategies to ensure geometric delivery accuracy, both prior to treatment and in real time. Some of these techniques are incorporated into the commercial system, while others are still under development. Pre-treatment setup verification is accomplished by registering a daily megavoltage CT image to the planning image. The setup is verified automatically using priority-based registration algorithms. While automatic registration is faster than manual registration and sometimes more accurate, a human observer must evaluate the registration results to ensure clinical acceptability. For registration techniques that do not require image reconstruction, one way to manually verify the registration results is to display selected rows of the CT sinogram as a scout view (after re-sorting to parallel, projections). Translational and roll setup corrections are implemented by precise adjustments to the couch or gantry start angle, respectively. However, to correct for pitch and yaw rotational setup errors, no simple mechanism is currently available, so the patient must be re-positioned about a designated rotation center. We propose a dynamic couch translation during treatment to approximately; correct for pitch and yaw rotational offsets. Such an approach would also be useful to correct for piece-wise rigid translations or rotations (bending), or differences in couch sag between the planning CT image set and the delivery.
590
$a
School code: 0262.
650
4
$a
Biophysics, Medical.
$3
1017681
650
4
$a
Health Sciences, Oncology.
$3
1018566
650
4
$a
Health Sciences, Radiology.
$3
1019076
690
$a
0574
690
$a
0760
690
$a
0992
710
2 0
$a
The University of Wisconsin - Madison.
$3
626640
773
0
$t
Dissertation Abstracts International
$g
67-09B.
790
$a
0262
790
1 0
$a
Mackie, Thomas Rockwell,
$e
advisor
791
$a
Ph.D.
792
$a
2006
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3234553
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9121965
電子資源
11.線上閱覽_V
電子書
EB W9121965
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入