Multi-layer composite transducer arrays for improved signal-to-noise ratio and bandwidth in medical ultrasound.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Multi-layer composite transducer arrays for improved signal-to-noise ratio and bandwidth in medical ultrasound./
作者:
Mills, David Martin.
面頁冊數:
135 p.
附註:
Source: Dissertation Abstracts International, Volume: 61-07, Section: B, page: 3714.
Contained By:
Dissertation Abstracts International61-07B.
標題:
Engineering, Biomedical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9977665
ISBN:
9780599835764
Multi-layer composite transducer arrays for improved signal-to-noise ratio and bandwidth in medical ultrasound.
Mills, David Martin.
Multi-layer composite transducer arrays for improved signal-to-noise ratio and bandwidth in medical ultrasound.
- 135 p.
Source: Dissertation Abstracts International, Volume: 61-07, Section: B, page: 3714.
Thesis (Ph.D.)--Duke University, 2000.
Increasing transducer bandwidth and signal-to-noise ratio (SNR) is fundamental to improving the quality of medical ultrasound images. In this dissertation, I describe a range of array transducers using new materials to improve both parameters. These new materials are stacked multi-layer composites of piezoelectric ceramics and polymer epoxies. The first transducer consists of 2 layers of posts (piezoelectric ceramic, PZT-5H) surrounded by soft epoxy. Experimentally, this 2 layer 1--3 composite transducer, yielded increased pulse-echo SNR by 5.2 dB and increased -6 dB bandwidth by a factor of 1.3, compared to the PZT-5H control. However, this structure required precision alignment of the posts greater than 90% of the post pitch (0.125mm) and a thin film bond line between the layers.
ISBN: 9780599835764Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Multi-layer composite transducer arrays for improved signal-to-noise ratio and bandwidth in medical ultrasound.
LDR
:03445nam 2200313 a 45
001
958410
005
20110704
008
110704s2000 eng d
020
$a
9780599835764
035
$a
(UMI)AAI9977665
035
$a
AAI9977665
040
$a
UMI
$c
UMI
100
1
$a
Mills, David Martin.
$3
1281872
245
1 0
$a
Multi-layer composite transducer arrays for improved signal-to-noise ratio and bandwidth in medical ultrasound.
300
$a
135 p.
500
$a
Source: Dissertation Abstracts International, Volume: 61-07, Section: B, page: 3714.
500
$a
Supervisor: Stephen W. Smith.
502
$a
Thesis (Ph.D.)--Duke University, 2000.
520
$a
Increasing transducer bandwidth and signal-to-noise ratio (SNR) is fundamental to improving the quality of medical ultrasound images. In this dissertation, I describe a range of array transducers using new materials to improve both parameters. These new materials are stacked multi-layer composites of piezoelectric ceramics and polymer epoxies. The first transducer consists of 2 layers of posts (piezoelectric ceramic, PZT-5H) surrounded by soft epoxy. Experimentally, this 2 layer 1--3 composite transducer, yielded increased pulse-echo SNR by 5.2 dB and increased -6 dB bandwidth by a factor of 1.3, compared to the PZT-5H control. However, this structure required precision alignment of the posts greater than 90% of the post pitch (0.125mm) and a thin film bond line between the layers.
520
$a
Thus, I developed a new multi-layer structure that will not require post alignment and would ideally be fabricated using thick film technology capable of volume production. Starting from a PZT-5H multi-layer transducer, cuts were made through the top layer and back-filled with epoxy, forming a PZT/epoxy composite layer on top of PZT layers, referred to as a multi-layer composite hybrid transducer. Finite element simulations (FEM) showed that for a 2 MHz phased array element with a single acoustic matching layer, the 3 layer hybrid structure increases the pulse-echo SNR by 11 dB compared to a single layer PZT-5H control element and increases -6 dB pulse-echo fractional bandwidth from 46% to 65%, a factor of 1.4, for the hybrid element. I fabricated a hybrid transducer array and obtained improvement in SNR by 11 dB over a PZT-5H control and increased -6 dB bandwidth from 54% to 59%, a factor of 1.1. However, the material properties of currently available thick film multi-layer transducers limit the performance of these hybrid arrays and need further refinement before simulated results can be matched experimentally.
520
$a
Additional FEM simulations were performed to further improve the transducer array designs. These simulations showed that for a 2 MHz phased array element with a single matching layer, the improved 3 layer hybrid structure increased the pulse-echo SNR by 16 dB and -6 dB pulse-echo fractional bandwidth from 58% to 75%, a factor of 1.3, for the hybrid element versus the PZT-5H control. Analogous FEM simulations of single crystal material (PZN-8%PT), showed increased pulse-echo SNR by only 3.1 dB versus the PZT-5H control and a -6 dB bandwidth of 108%.
590
$a
School code: 0066.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Engineering, Electronics and Electrical.
$3
626636
650
4
$a
Health Sciences, Radiology.
$3
1019076
690
$a
0541
690
$a
0544
690
$a
0574
710
2 0
$a
Duke University.
$3
569686
773
0
$t
Dissertation Abstracts International
$g
61-07B.
790
$a
0066
790
1 0
$a
Smith, Stephen W.,
$e
advisor
791
$a
Ph.D.
792
$a
2000
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9977665
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9121875
電子資源
11.線上閱覽_V
電子書
EB W9121875
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入