語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Polymeric textile stents: Prototypi...
~
Irsale, Swagat Appasaheb.
FindBook
Google Book
Amazon
博客來
Polymeric textile stents: Prototyping and modeling.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Polymeric textile stents: Prototyping and modeling./
作者:
Irsale, Swagat Appasaheb.
面頁冊數:
166 p.
附註:
Director: Sabit Adanur.
Contained By:
Dissertation Abstracts International66-12B.
標題:
Engineering, Biomedical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3201447
ISBN:
9780542465994
Polymeric textile stents: Prototyping and modeling.
Irsale, Swagat Appasaheb.
Polymeric textile stents: Prototyping and modeling.
- 166 p.
Director: Sabit Adanur.
Thesis (Ph.D.)--Auburn University, 2005.
Although metal stents have been implanted for more than a decade, performance deficiencies still exist. The current study focuses on prototyping and modeling of braided structures to be used as stents, hence called 'textile stents'. Textile stents are self-expanding stents. The objective is to establish guidelines for commercial manufacturing of textile stents which can become major substitutes for metal stents. Textile stents and bifurcated textile stents were manufactured. Manufacturing variables braid angle, braid diameter, and heatset time had statistically significant effects (p = 0.0001) on the compression force of textile stents. A chart is compiled which categorizes factors affecting the performance of textile stents. Strong correlation (adjusted R 2 = 0.9999) between radial and in vitro (unidirectional) compressions of textile stents was observed. Agreement between values of Young's modulus of textile stents derived by the mechanical model (strain energy method) to those of the experimental was good (adjusted R2 = 0.7955). Stress-strain curves were obtained by strip testing of textile stents on an InstronRTM. The empirical model showed strong correlation between theoretical and experimental values of compression force for 1.27 cm (adjusted R2= 0.8669) and 1.9 cm (adjusted R2 = 0.9251) diameter textile stents. Two-Factor ANOVA showed statistically significant effect (p = 0.00051 for 0.4 cm artery diameter, p = 0.00013 for 0.8 cm artery diameter, p = 0.01716 for 1.2 cm artery diameter, p = 0.01240 for 1.6 cm artery diameter, p = 0.0309 for 2.5 cm artery diameter) of blood input velocity on exit velocity, determined by AnsysRTM FLOTRAN. Monofilament denier also showed statistically significant effect (p = 0.04395 for 0.4 cm, p = 0.03814 for 0.8 cm, p = 0.01491 for 1.2 cm) on exit velocity for all mentioned artery diameters except 1.6 and 2.5 cm. Textile stent entrance and exit effects and blood flow behavior in textile stented artery segment were helpful in understanding restenosis. Application of textile stents as substitute to metal stents is feasible.
ISBN: 9780542465994Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Polymeric textile stents: Prototyping and modeling.
LDR
:02945nam 2200277 a 45
001
951802
005
20110617
008
110617s2005 ||||||||||||||||| ||eng d
020
$a
9780542465994
035
$a
(UMI)AAI3201447
035
$a
AAI3201447
040
$a
UMI
$c
UMI
100
1
$a
Irsale, Swagat Appasaheb.
$3
1275809
245
1 0
$a
Polymeric textile stents: Prototyping and modeling.
300
$a
166 p.
500
$a
Director: Sabit Adanur.
500
$a
Source: Dissertation Abstracts International, Volume: 66-12, Section: B, page: 6904.
502
$a
Thesis (Ph.D.)--Auburn University, 2005.
520
$a
Although metal stents have been implanted for more than a decade, performance deficiencies still exist. The current study focuses on prototyping and modeling of braided structures to be used as stents, hence called 'textile stents'. Textile stents are self-expanding stents. The objective is to establish guidelines for commercial manufacturing of textile stents which can become major substitutes for metal stents. Textile stents and bifurcated textile stents were manufactured. Manufacturing variables braid angle, braid diameter, and heatset time had statistically significant effects (p = 0.0001) on the compression force of textile stents. A chart is compiled which categorizes factors affecting the performance of textile stents. Strong correlation (adjusted R 2 = 0.9999) between radial and in vitro (unidirectional) compressions of textile stents was observed. Agreement between values of Young's modulus of textile stents derived by the mechanical model (strain energy method) to those of the experimental was good (adjusted R2 = 0.7955). Stress-strain curves were obtained by strip testing of textile stents on an InstronRTM. The empirical model showed strong correlation between theoretical and experimental values of compression force for 1.27 cm (adjusted R2= 0.8669) and 1.9 cm (adjusted R2 = 0.9251) diameter textile stents. Two-Factor ANOVA showed statistically significant effect (p = 0.00051 for 0.4 cm artery diameter, p = 0.00013 for 0.8 cm artery diameter, p = 0.01716 for 1.2 cm artery diameter, p = 0.01240 for 1.6 cm artery diameter, p = 0.0309 for 2.5 cm artery diameter) of blood input velocity on exit velocity, determined by AnsysRTM FLOTRAN. Monofilament denier also showed statistically significant effect (p = 0.04395 for 0.4 cm, p = 0.03814 for 0.8 cm, p = 0.01491 for 1.2 cm) on exit velocity for all mentioned artery diameters except 1.6 and 2.5 cm. Textile stent entrance and exit effects and blood flow behavior in textile stented artery segment were helpful in understanding restenosis. Application of textile stents as substitute to metal stents is feasible.
590
$a
School code: 0012.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Textile Technology.
$3
1020710
690
$a
0541
690
$a
0994
710
2
$a
Auburn University.
$3
1020457
773
0
$t
Dissertation Abstracts International
$g
66-12B.
790
$a
0012
790
1 0
$a
Adanur, Sabit,
$e
advisor
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3201447
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9118213
電子資源
11.線上閱覽_V
電子書
EB W9118213
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入