語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Optimization of ventilation system d...
~
Zhou, Liang.
FindBook
Google Book
Amazon
博客來
Optimization of ventilation system design and operation in office environment.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Optimization of ventilation system design and operation in office environment./
作者:
Zhou, Liang.
面頁冊數:
209 p.
附註:
Source: Dissertation Abstracts International, Volume: 68-09, Section: B, page: 6165.
Contained By:
Dissertation Abstracts International68-09B.
標題:
Engineering, Civil. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR31135
ISBN:
9780494311356
Optimization of ventilation system design and operation in office environment.
Zhou, Liang.
Optimization of ventilation system design and operation in office environment.
- 209 p.
Source: Dissertation Abstracts International, Volume: 68-09, Section: B, page: 6165.
Thesis (Ph.D.)--Concordia University (Canada), 2007.
This thesis also provides a brief discussion regarding the potential advancements of this work, with the hope to provide a practical tool for aiding decision making during building system design and operation process.
ISBN: 9780494311356Subjects--Topical Terms:
783781
Engineering, Civil.
Optimization of ventilation system design and operation in office environment.
LDR
:05278nam 2200301 a 45
001
951307
005
20110609
008
110609s2007 ||||||||||||||||| ||eng d
020
$a
9780494311356
035
$a
(UMI)AAINR31135
035
$a
AAINR31135
040
$a
UMI
$c
UMI
100
1
$a
Zhou, Liang.
$3
1275287
245
1 0
$a
Optimization of ventilation system design and operation in office environment.
300
$a
209 p.
500
$a
Source: Dissertation Abstracts International, Volume: 68-09, Section: B, page: 6165.
502
$a
Thesis (Ph.D.)--Concordia University (Canada), 2007.
520
$a
This thesis also provides a brief discussion regarding the potential advancements of this work, with the hope to provide a practical tool for aiding decision making during building system design and operation process.
520
$a
With growing concern about the impact of indoor environment quality on office workers' well-being and productivity, coupled with the concern over the rising energy costs for space heating and cooling in office building sector, ventilation principles that integrate flexible and responsive elements have grown in popularity in office buildings. Such advanced elements as Underfloor air distribution (UFAD), passive swirl diffusers, and demand control on ventilation rate pose challenges to system design and operation.
520
$a
This thesis is concerned with the development and implementation of a practical and robust optimization scheme, with the goal of aiding the office building designers and operators to enhance the thermal comfort and indoor air quality (IAQ without sacrificing energy costs of ventilation. The path taken is a simulation-based optimization approach by using computational fluid dynamics (CFD) techniques in conjunction with genetic algorithm (GA), with the integration of an artificial neural network (ANN) for response surface approximation (RSA) and for speeding up fitness evaluations inside the GA loop. It breaks the problem into three sequential steps.
520
$a
First, the performance of various ventilation systems was predicted and evaluated by CFD simulations for an assumed set of indoor/outdoor environmental conditions. By varying the external temperature, the internal heat load, the geometric configuration in the office, the supply air states, and the placement of air terminals in the CFD model and examining the consequent effects, the influential parameters significantly affecting the objectives of interest can be identified and examined. Though CFD is often quoted as a method of acquiring detail and accuracy, the excessive computational costs retards the direct conflation of it into the optimization underway. It is then a worthy effort establishing a low fidelity model for RSA, which can be then used in the place of CFD to evaluate fitness during optimization search. In the second step, an ANN model was trained and tested for this purpose by using data obtained from pre-conducted CFD simulations. When created properly, such a model significantly decreases the computing time for optimization objectives and constraints calculation without compromising accuracy. Finally, a GA was applied in the third step to search for the near-optimal combinations of the controlled variables, using the pre-trained ANN model for fitness evaluations inside searching loops. The objective function is formulated in a way attempting to integrate and weight indicators such as predicted mean vote (PMV for thermal comfort assessment), ventilation effectiveness (epsilon v for IAQ evaluation), and energy usage by space cooling and a supply fan into one performance index.
520
$a
The CFD simulations in this study are pre-validated using experimental data from baseline cases with both UFAD system and ceiling mounted mixing system (MS). Good agreements between the measured and the predicted air velocity/temperature profiles provide the justification for the current choice of turbulence model and the present specification of boundary conditions. It can be observed that the ANN model obtained and used cuts down the execution time from 17 hours per CFD simulation (thus, per fitness evaluation in GA originally) to a time scale of a few minutes for the whole GA search (invoking approximate 5000 fitness evaluations in total). Within a particular office space with a given indoor pollutant emission rate and internal/external thermal conditions, the final optimization solution contains a set of near optimal ventilation system design/operation parameters, including the ventilation system type, diffuser type, number of diffusers, supply air temperature, amount of supply air, as well as the location of diffusers and return grilles, which can substantially enhance the thermal comfort level and IAQ with saving in the energy costs simultaneously. Such optimization results indicate that the present choices of objective function and optimization approach are able to result in great improvements in the design and operation of ventilation systems in office environments.
590
$a
School code: 0228.
650
4
$a
Engineering, Civil.
$3
783781
650
4
$a
Engineering, Mechanical.
$3
783786
690
$a
0543
690
$a
0548
710
2
$a
Concordia University (Canada).
$3
1018569
773
0
$t
Dissertation Abstracts International
$g
68-09B.
790
$a
0228
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR31135
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9118178
電子資源
11.線上閱覽_V
電子書
EB W9118178
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入