語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Computation of three-dimensional imp...
~
Jain, Ameet Kumar.
FindBook
Google Book
Amazon
博客來
Computation of three-dimensional implant coordinates for prostate brachytherapy.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Computation of three-dimensional implant coordinates for prostate brachytherapy./
作者:
Jain, Ameet Kumar.
面頁冊數:
320 p.
附註:
Adviser: Gabor Fichtinger.
Contained By:
Dissertation Abstracts International68-11B.
標題:
Computer Science. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3288604
ISBN:
9780549313090
Computation of three-dimensional implant coordinates for prostate brachytherapy.
Jain, Ameet Kumar.
Computation of three-dimensional implant coordinates for prostate brachytherapy.
- 320 p.
Adviser: Gabor Fichtinger.
Thesis (Ph.D.)--The Johns Hopkins University, 2008.
Prostate Brachytherapy has emerged as a common and effective treatment modality for early stage low risk prostate cancer, wherein around 75 small radioactive seeds are implanted into the prostate to eradicate the cancer by emitting radiation. The subject of this dissertation is the capability to intra-operatively monitor the 3D seed locations using 2D X-ray images and make treatment adjustments, promising to make a significant improvement in cancer control. We modeled the overall medical problem as a cascade of computer science problems, predominantly in image processing, pose estimation, minimum-weight multipartite graph matching and 3D image reconstruction. The primary contribution of this dissertation is a theoretical and computational solution using techniques like linear algebra, error analysis, combinatorial and non-linear optimization. The solution is consolidated into a simple software module and integrated with a commercial Brachytherapy installation. The contributions of the dissertation have been extensively validated using simulation and phantom experiments. Furthermore; the software system has been successfully employed intraoperatively, for treatment control in a phase-I trial with six patients. From a clinical perspective, the proposed solution does not alter the current surgical workflow, uses already existing infrastructure and is economically feasible.
ISBN: 9780549313090Subjects--Topical Terms:
626642
Computer Science.
Computation of three-dimensional implant coordinates for prostate brachytherapy.
LDR
:02305nam 2200289 a 45
001
949328
005
20110525
008
110525s2008 ||||||||||||||||| ||eng d
020
$a
9780549313090
035
$a
(UMI)AAI3288604
035
$a
AAI3288604
040
$a
UMI
$c
UMI
100
1
$a
Jain, Ameet Kumar.
$3
1272711
245
1 0
$a
Computation of three-dimensional implant coordinates for prostate brachytherapy.
300
$a
320 p.
500
$a
Adviser: Gabor Fichtinger.
500
$a
Source: Dissertation Abstracts International, Volume: 68-11, Section: B, page: 7239.
502
$a
Thesis (Ph.D.)--The Johns Hopkins University, 2008.
520
$a
Prostate Brachytherapy has emerged as a common and effective treatment modality for early stage low risk prostate cancer, wherein around 75 small radioactive seeds are implanted into the prostate to eradicate the cancer by emitting radiation. The subject of this dissertation is the capability to intra-operatively monitor the 3D seed locations using 2D X-ray images and make treatment adjustments, promising to make a significant improvement in cancer control. We modeled the overall medical problem as a cascade of computer science problems, predominantly in image processing, pose estimation, minimum-weight multipartite graph matching and 3D image reconstruction. The primary contribution of this dissertation is a theoretical and computational solution using techniques like linear algebra, error analysis, combinatorial and non-linear optimization. The solution is consolidated into a simple software module and integrated with a commercial Brachytherapy installation. The contributions of the dissertation have been extensively validated using simulation and phantom experiments. Furthermore; the software system has been successfully employed intraoperatively, for treatment control in a phase-I trial with six patients. From a clinical perspective, the proposed solution does not alter the current surgical workflow, uses already existing infrastructure and is economically feasible.
590
$a
School code: 0098.
650
4
$a
Computer Science.
$3
626642
650
4
$a
Health Sciences, Medicine and Surgery.
$3
1017756
650
4
$a
Health Sciences, Radiology.
$3
1019076
690
$a
0564
690
$a
0574
690
$a
0984
710
2
$a
The Johns Hopkins University.
$3
1017431
773
0
$t
Dissertation Abstracts International
$g
68-11B.
790
$a
0098
790
1 0
$a
Fichtinger, Gabor,
$e
advisor
791
$a
Ph.D.
792
$a
2008
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3288604
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9116955
電子資源
11.線上閱覽_V
電子書
EB W9116955
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入