Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Broadband all-optical ultrasound tra...
~
Hou, Yang.
Linked to FindBook
Google Book
Amazon
博客來
Broadband all-optical ultrasound transducers for high-resolution ultrasound imaging.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Broadband all-optical ultrasound transducers for high-resolution ultrasound imaging./
Author:
Hou, Yang.
Description:
143 p.
Notes:
Advisers: Matthew O'Donnell; Theodore B. Norris.
Contained By:
Dissertation Abstracts International69-03B.
Subject:
Biophysics, Medical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3304988
ISBN:
9780549509400
Broadband all-optical ultrasound transducers for high-resolution ultrasound imaging.
Hou, Yang.
Broadband all-optical ultrasound transducers for high-resolution ultrasound imaging.
- 143 p.
Advisers: Matthew O'Donnell; Theodore B. Norris.
Thesis (Ph.D.)--University of Michigan, 2008.
The use and development of high-frequency ultrasound has dramatically expanded the frontiers of ultrasound imaging, making better image resolution possible in various clinical applications. Real-time 3D high-resolution ultrasound imaging requires 2D high-frequency (>30 MHz) transducer arrays, which are not available with conventional piezoelectric technology. Optoacoustic transduction relying on optical generation and detection of ultrasound is an attractive alternative, which utilizes two laser beams as input/output vectors instead of electronic signals.
ISBN: 9780549509400Subjects--Topical Terms:
1017681
Biophysics, Medical.
Broadband all-optical ultrasound transducers for high-resolution ultrasound imaging.
LDR
:03451nam 2200325 a 45
001
947987
005
20110524
008
110524s2008 ||||||||||||||||| ||eng d
020
$a
9780549509400
035
$a
(UMI)AAI3304988
035
$a
AAI3304988
040
$a
UMI
$c
UMI
100
1
$a
Hou, Yang.
$3
1271448
245
1 0
$a
Broadband all-optical ultrasound transducers for high-resolution ultrasound imaging.
300
$a
143 p.
500
$a
Advisers: Matthew O'Donnell; Theodore B. Norris.
500
$a
Source: Dissertation Abstracts International, Volume: 69-03, Section: B, page: 1764.
502
$a
Thesis (Ph.D.)--University of Michigan, 2008.
520
$a
The use and development of high-frequency ultrasound has dramatically expanded the frontiers of ultrasound imaging, making better image resolution possible in various clinical applications. Real-time 3D high-resolution ultrasound imaging requires 2D high-frequency (>30 MHz) transducer arrays, which are not available with conventional piezoelectric technology. Optoacoustic transduction relying on optical generation and detection of ultrasound is an attractive alternative, which utilizes two laser beams as input/output vectors instead of electronic signals.
520
$a
Previously, the most efficient optoacoustic transmitter is a 25 mum black PDMS film, and the state of the art optoacoustic detector utilizes an 11 mum Fabry-Perot polymer etalon. Both devices operate at below 50 MHz, and an integrated structure combining both optoacoustic transmitters and detectors has not been designed and fabricated.
520
$a
This thesis addresses the development of integrated broadband all-optical ultrasound transducers. Optimized black PDMS films and innovative gold nanostructure films are first presented as efficient optoacoustic transmitters, both of which are capable of generating ultrasound in the 50-100 MHz frequency range with surface acoustic pressure far exceeding 100 MPa. Thinner polymer etalons are then demonstrated for building ultrasound detection arrays at above 50 MHz, and 3D photoacoustic imaging experiments using etalon arrays have shown axial and lateral resolutions better than 20 mum. The first integrated all-optical ultrasound transducer combining the etalon structure and the gold nanostructure has been designed, fabricated, and evaluated. Pulse-echo signals display bandwidths of 57 MHz. High-resolution ultrasound imaging capabilities have been demonstrated using a 1-D synthetic aperture formed by mechanically scanning the imaging target, where the -6 dB lateral resolution is 38 mum. In addition, a theta-array imaging system combining black PDMS and etalon structures have been developed for 3D ultrasound imaging. Bandwidths of pulse-echo signals are over 50 MHz, and reconstructed ultrasonic images capture the imaging targets with reasonable accuracy. Optical and acoustical characterization of the optoacoustic devices, as well as high-resolution imaging results, strongly suggest that all-optical ultrasound transducers are suitable for 2D high-frequency arrays enabling real-time 3D high-resolution ultrasound imaging.
590
$a
School code: 0127.
650
4
$a
Biophysics, Medical.
$3
1017681
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Health Sciences, Radiology.
$3
1019076
690
$a
0541
690
$a
0574
690
$a
0760
710
2
$a
University of Michigan.
$3
777416
773
0
$t
Dissertation Abstracts International
$g
69-03B.
790
$a
0127
790
1 0
$a
Norris, Theodore B.,
$e
advisor
790
1 0
$a
O'Donnell, Matthew,
$e
advisor
791
$a
Ph.D.
792
$a
2008
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3304988
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9115714
電子資源
11.線上閱覽_V
電子書
EB W9115714
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login