語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
A comparison of intensity modulated ...
~
Flynn, Ryan.
FindBook
Google Book
Amazon
博客來
A comparison of intensity modulated x-ray therapy to intensity modulated proton therapy for the delivery of non-uniform dose distributions.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
A comparison of intensity modulated x-ray therapy to intensity modulated proton therapy for the delivery of non-uniform dose distributions./
作者:
Flynn, Ryan.
面頁冊數:
125 p.
附註:
Advisers: Thomas Rockwell Mackie; Robert Jeraj.
Contained By:
Dissertation Abstracts International68-12B.
標題:
Biophysics, Medical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3294028
ISBN:
9780549381686
A comparison of intensity modulated x-ray therapy to intensity modulated proton therapy for the delivery of non-uniform dose distributions.
Flynn, Ryan.
A comparison of intensity modulated x-ray therapy to intensity modulated proton therapy for the delivery of non-uniform dose distributions.
- 125 p.
Advisers: Thomas Rockwell Mackie; Robert Jeraj.
Thesis (Ph.D.)--The University of Wisconsin - Madison, 2007.
The distribution of biological characteristics such as clonogen density, proliferation, and hypoxia throughout tumors is generally non-uniform, therefore it follows that the optimal dose prescriptions should also be non-uniform and tumor-specific. Advances in intensity modulated x-ray therapy (IMXT) technology have made the delivery of custom-made non-uniform dose distributions possible in practice. Intensity modulated proton therapy (IMPT) has the potential to deliver non-uniform dose distributions as well, while significantly reducing normal tissue and organ at risk dose relative to IMXT.
ISBN: 9780549381686Subjects--Topical Terms:
1017681
Biophysics, Medical.
A comparison of intensity modulated x-ray therapy to intensity modulated proton therapy for the delivery of non-uniform dose distributions.
LDR
:03181nam 2200325 a 45
001
947090
005
20110523
008
110523s2007 ||||||||||||||||| ||eng d
020
$a
9780549381686
035
$a
(UMI)AAI3294028
035
$a
AAI3294028
040
$a
UMI
$c
UMI
100
1
$a
Flynn, Ryan.
$3
1270510
245
1 2
$a
A comparison of intensity modulated x-ray therapy to intensity modulated proton therapy for the delivery of non-uniform dose distributions.
300
$a
125 p.
500
$a
Advisers: Thomas Rockwell Mackie; Robert Jeraj.
500
$a
Source: Dissertation Abstracts International, Volume: 68-12, Section: B, page: 8105.
502
$a
Thesis (Ph.D.)--The University of Wisconsin - Madison, 2007.
520
$a
The distribution of biological characteristics such as clonogen density, proliferation, and hypoxia throughout tumors is generally non-uniform, therefore it follows that the optimal dose prescriptions should also be non-uniform and tumor-specific. Advances in intensity modulated x-ray therapy (IMXT) technology have made the delivery of custom-made non-uniform dose distributions possible in practice. Intensity modulated proton therapy (IMPT) has the potential to deliver non-uniform dose distributions as well, while significantly reducing normal tissue and organ at risk dose relative to IMXT.
520
$a
In this work, a specialized treatment planning system was developed for the purpose of optimizing and comparing biologically based IMXT and IMPT plans. The IMXT systems of step-and-shoot (IMXT-SAS) and helical tomotherapy (IMXT-HT) and the IMPT systems of intensity modulated spot scanning (IMPT-SS) and distal gradient tracking (IMPT-DGT), were simulated.
520
$a
A thorough phantom study was conducted in which several subvolumes, which were contained within a base tumor region, were boosted or avoided with IMXT and IMPT. Different boosting situations were simulated by varying the size, proximity, and the doses prescribed to the subvolumes, and the size of the phantom. IMXT and IMPT were also compared for a whole brain radiation therapy (WBRT) case, in which a brain metastasis was simultaneously boosted and the hippocampus was avoided. Finally, IMXT and IMPT dose distributions were compared for the case of non-uniform dose prescription in a head and neck cancer patient that was based on PET imaging with the Cu(II)-diacetyl-bis(N4-methylthiosemicarbazone (Cu-ATSM) hypoxia marker.
520
$a
The non-uniform dose distributions within the tumor region were comparable for IMXT and IMPT. IMPT, however, was capable of delivering the same non-uniform dose distributions within a tumor using a 180° arc as for a full 360° rotation, which resulted in the reduction of normal tissue integral dose by a factor of up to three relative to IMXT, and the complete sparing of organs at risk distal to the tumor region.
590
$a
School code: 0262.
650
4
$a
Biophysics, Medical.
$3
1017681
650
4
$a
Physics, Radiation.
$3
1019212
690
$a
0756
690
$a
0760
710
2
$a
The University of Wisconsin - Madison.
$3
626640
773
0
$t
Dissertation Abstracts International
$g
68-12B.
790
$a
0262
790
1 0
$a
Jeraj, Robert,
$e
advisor
790
1 0
$a
Mackie, Thomas Rockwell,
$e
advisor
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3294028
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9114894
電子資源
11.線上閱覽_V
電子書
EB W9114894
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入