語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Data-driven approach for control per...
~
Yu, Jie.
FindBook
Google Book
Amazon
博客來
Data-driven approach for control performance monitoring and fault diagnosis.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Data-driven approach for control performance monitoring and fault diagnosis./
作者:
Yu, Jie.
面頁冊數:
222 p.
附註:
Adviser: S. Joe Qin.
Contained By:
Dissertation Abstracts International68-05B.
標題:
Engineering, Chemical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3268384
ISBN:
9780549069515
Data-driven approach for control performance monitoring and fault diagnosis.
Yu, Jie.
Data-driven approach for control performance monitoring and fault diagnosis.
- 222 p.
Adviser: S. Joe Qin.
Thesis (Ph.D.)--The University of Texas at Austin, 2007.
Due to the industrial value, control performance and process monitoring have attracted increasing attention in recent years. However, there still exist challenges that restrict the industrial applications of monitoring technology. This dissertation presents some innovative solutions to the monitoring issues.
ISBN: 9780549069515Subjects--Topical Terms:
1018531
Engineering, Chemical.
Data-driven approach for control performance monitoring and fault diagnosis.
LDR
:03545nam 2200301 a 45
001
939065
005
20110512
008
110512s2007 ||||||||||||||||| ||eng d
020
$a
9780549069515
035
$a
(UMI)AAI3268384
035
$a
AAI3268384
040
$a
UMI
$c
UMI
100
1
$a
Yu, Jie.
$3
1263053
245
1 0
$a
Data-driven approach for control performance monitoring and fault diagnosis.
300
$a
222 p.
500
$a
Adviser: S. Joe Qin.
500
$a
Source: Dissertation Abstracts International, Volume: 68-05, Section: B, page: 3234.
502
$a
Thesis (Ph.D.)--The University of Texas at Austin, 2007.
520
$a
Due to the industrial value, control performance and process monitoring have attracted increasing attention in recent years. However, there still exist challenges that restrict the industrial applications of monitoring technology. This dissertation presents some innovative solutions to the monitoring issues.
520
$a
To avoid the interactor requirement of minimum variance control (MVC) benchmark, a data-driven covariance monitoring framework is established. Relative to a user-defined benchmark, generalized eigenvalue analysis is employed to extract the directions with the worst performance. A statistical inference strategy is then developed to identify the worse or better performance directions and subspace. The covariance based indices are further derived to assess the performance degradation or improvement. To diagnose the controlled variables causing the performance change, two types of multivariate contribution methods are proposed. One is to evaluate the significance of the eigenvector loadings while the other to examine the angle between each variable and the worse/better subspace.
520
$a
Complementary to the data-driven performance monitoring scheme, a simplified solution to MVC benchmark is also developed. A right diagonal interactor is first factorized from process time delays and the corresponding MVC benchmark is derived with numerical simplicity. For more general MIMO processes, left and right diagonal interactors are integrated to characterize the more complex delay structure. The MVC estimation using the left/right diagonal interactors are presented. To further improve multivariable control performance, an iterative strategy of output weighting selection is proposed. Eigenvalue decomposition is implemented on the output covariance to find the directions with the largest variance inflation. A nondiagonal weighting matrix is then designed with respect to the eigendirections and more importance proportional to the corresponding eigenvalues is assigned.
520
$a
In addition to control performance monitoring, process monitoring is also investigated with focus on fault detection and diagnosis of multistage overlay lithography processes. In our work, a multistage state-space model for the misalignment errors is developed from the physical principles and then formulated into the general mixed linear model. Subsequently, variance component analysis is employed to estimate the mean and variance components of the potential fault sources. A hypothesis testing procedure is adopted to detect the active faults in different layers while the mean/variance estimates are used to diagnose their magnitude and orientation.
590
$a
School code: 0227.
650
4
$a
Engineering, Chemical.
$3
1018531
690
$a
0542
710
2
$a
The University of Texas at Austin.
$b
Chemical Engineering.
$3
1023637
773
0
$t
Dissertation Abstracts International
$g
68-05B.
790
$a
0227
790
1 0
$a
Qin, S. Joe,
$e
advisor
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3268384
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9109253
電子資源
11.線上閱覽_V
電子書
EB W9109253
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入