Pure fluid and binary mixture transients of a heat pump equipped with a distillation column: An experimental and numerical investigation.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Pure fluid and binary mixture transients of a heat pump equipped with a distillation column: An experimental and numerical investigation./
作者:
Gebbie, James George.
面頁冊數:
336 p.
附註:
Adviser: Michael K. Jensen.
Contained By:
Dissertation Abstracts International63-12B
標題:
Engineering, Mechanical -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3072052
ISBN:
0493949275
Pure fluid and binary mixture transients of a heat pump equipped with a distillation column: An experimental and numerical investigation.
Gebbie, James George.
Pure fluid and binary mixture transients of a heat pump equipped with a distillation column: An experimental and numerical investigation.
- 336 p.
Adviser: Michael K. Jensen.
Thesis (Ph.D.)--Rensselaer Polytechnic Institute, 2002.
*This dissertation is a multimedia document (contains text and other applications not available in printed format)
ISBN: 0493949275Subjects--Topical Terms:
1260257
Engineering, Mechanical
Pure fluid and binary mixture transients of a heat pump equipped with a distillation column: An experimental and numerical investigation.
LDR
:03105nam 2200301 a 45
001
936701
005
20110510
008
110510s2002 eng d
020
$a
0493949275
035
$a
(UnM)AAI3072052
035
$a
AAI3072052
040
$a
UnM
$c
UnM
100
1
$a
Gebbie, James George.
$3
1260534
245
1 0
$a
Pure fluid and binary mixture transients of a heat pump equipped with a distillation column: An experimental and numerical investigation.
300
$a
336 p.
500
$a
Adviser: Michael K. Jensen.
500
$a
Source: Dissertation Abstracts International, Volume: 63-12, Section: B, page: 6052.
502
$a
Thesis (Ph.D.)--Rensselaer Polytechnic Institute, 2002.
520
$a
*This dissertation is a multimedia document (contains text and other applications not available in printed format)
520
$a
The transient behavior of a heat pump equipped with a distillation column has been experimentally and numerically investigated. An experimental water-to-water heat pump system was tested using pure R32, and using a 30/70% by mass mixture of R32/134a. A set (24 factorial design) of experiments were conducted with the pure fluid and with the mixture. The factors, each with a high and low setting, were: sump heater power, evaporator heat transfer fluid mass flow rate, condenser heat transfer fluid mass flow rate, and compressor speed. Additionally, a set of computer models were written to predict the steady-state behaviors of the compressor, condenser, and evaporator. The models were validated using the experimental data, then they were used to test whether or not it might be possible to model the transient performance of these components on a quasi-steady basis.
520
$a
Changes in startup transient behavior due to the four factors were not always as expected. An increase in sump heater power did make the pure fluid transients more rapid, but the mixture transient behavior was relatively unchanged. The mixture tests differed in that increases in sump heater power increased not only the mass introduction rate to the refrigerant loop, but also the effectiveness of the distillation column. Changes in end-of-test capacities due to the four factors were generally as expected. A complete discussion of the cause and effects of changes in transient and end-of-test behavior, due to the factorial changes, is presented
520
$a
The steady-state compressor, condenser, and evaporator models generally predicted end-of-test performance within 5%. Good agreement was also obtained when the models were used to predict transient performance on a quasi-steady basis. On average, agreement between the models and the transient data was within 5% for times greater than 10 minutes after startup. This indicates that a quasi-steady system model, integrating all heat pump components, should predict transient data reasonably well.
590
$a
School code: 0185
650
$a
Engineering, Mechanical
$3
1260257
690
$a
054
710
2
$a
Rensselaer Polytechnic Institute
$3
1260535
773
0
$t
Dissertation Abstracts International
$g
63-12B
790
$a
018
790
1
$a
Jensen, Michael K.,
$e
adviso
791
$a
Ph.D
792
$a
200
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3072052
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9107287
電子資源
11.線上閱覽_V
電子書
EB W9107287
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入