語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
The capability of a solid sorbent de...
~
Texas Tech University.
FindBook
Google Book
Amazon
博客來
The capability of a solid sorbent desiccant unit at removing selected indoor air quality-related microorganisms from the air.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
The capability of a solid sorbent desiccant unit at removing selected indoor air quality-related microorganisms from the air./
作者:
Larranaga, Michael David.
面頁冊數:
228 p.
附註:
Adviser: Mario G. Beruvides.
Contained By:
Dissertation Abstracts International67-04B.
標題:
Biology, Microbiology. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3215627
ISBN:
9780542663550
The capability of a solid sorbent desiccant unit at removing selected indoor air quality-related microorganisms from the air.
Larranaga, Michael David.
The capability of a solid sorbent desiccant unit at removing selected indoor air quality-related microorganisms from the air.
- 228 p.
Adviser: Mario G. Beruvides.
Thesis (Ph.D.)--Texas Tech University, 2004.
Throughout history diverse cultures and societies have appreciated the importance of a clean and healthy indoor environment. In western societies today, most people spend greater than 90% of their time indoors. Reports involving buildings with indoor air-related problems have appeared increasingly in the medical and scientific literature, although this problem has been with humans for centuries. Sick building syndrome (SBS), a common term for explaining symptoms that result from individuals' exposure to poor indoor air quality (IAQ), was first recognized as an important problem affecting occupants in certain buildings in 1982. The presence of moisture, fungi, spores, and fungal growth in sick buildings has become consistently associated with SBS. Poorly maintained heating, ventilation, and air conditioning (HVAC) systems have been recognized as sources of microorganisms, including fungi. Undesirable moisture levels and fungal growth indoors represent a public health concern inadequately addressed by building, health, or housing codes. Drying the ventilation air via the honeycomb wheel desiccant based cooling is a cost effective method of humidity control and removes statistically significant concentrations of IAQ-related microorganisms from the air. Controlling humidity is crucial for human comfort, minimizing adverse health effects associated with high humidity and maximizing the structural integrity of buildings. Several authors have stated that the use of active desiccants enhances the quality of the indoor air by helping to maintain comfort criteria (temperature, humidity and ventilation, removing particulates and bioaerosols from the air, and removing chemical pollutants from the air. The capabilities of a rotary wheel solid-desiccant dehumidifier at removing selected IAQ-related fungal organisms from the airstream were quantified at temperatures ranging from 60°F to 360°F at 100°F intervals. Average removal efficiencies for viable concentrations of spores ranged from 42%-98% for Asrpergillus niger, Cladosporium claosporioidies, and Penicillium chrysogenum at the four temperature settings. Average removal efficiencies for total spore concentrations ranged from 30%-95% for the same organisms and temperature settings. The results of this study show that utilizing a rotating honeycomb desiccant apparatus in conjunction with conventional air conditioning can significantly reduce the airborne concentrations of IAQ-related microorganisms delivered to the indoor air.
ISBN: 9780542663550Subjects--Topical Terms:
1017734
Biology, Microbiology.
The capability of a solid sorbent desiccant unit at removing selected indoor air quality-related microorganisms from the air.
LDR
:03478nmm 2200289 a 45
001
865465
005
20100728
008
100728s2004 ||||||||||||||||| ||eng d
020
$a
9780542663550
035
$a
(UMI)AAI3215627
035
$a
AAI3215627
040
$a
UMI
$c
UMI
100
1
$a
Larranaga, Michael David.
$3
1033898
245
1 4
$a
The capability of a solid sorbent desiccant unit at removing selected indoor air quality-related microorganisms from the air.
300
$a
228 p.
500
$a
Adviser: Mario G. Beruvides.
500
$a
Source: Dissertation Abstracts International, Volume: 67-04, Section: B, page: 2174.
502
$a
Thesis (Ph.D.)--Texas Tech University, 2004.
520
$a
Throughout history diverse cultures and societies have appreciated the importance of a clean and healthy indoor environment. In western societies today, most people spend greater than 90% of their time indoors. Reports involving buildings with indoor air-related problems have appeared increasingly in the medical and scientific literature, although this problem has been with humans for centuries. Sick building syndrome (SBS), a common term for explaining symptoms that result from individuals' exposure to poor indoor air quality (IAQ), was first recognized as an important problem affecting occupants in certain buildings in 1982. The presence of moisture, fungi, spores, and fungal growth in sick buildings has become consistently associated with SBS. Poorly maintained heating, ventilation, and air conditioning (HVAC) systems have been recognized as sources of microorganisms, including fungi. Undesirable moisture levels and fungal growth indoors represent a public health concern inadequately addressed by building, health, or housing codes. Drying the ventilation air via the honeycomb wheel desiccant based cooling is a cost effective method of humidity control and removes statistically significant concentrations of IAQ-related microorganisms from the air. Controlling humidity is crucial for human comfort, minimizing adverse health effects associated with high humidity and maximizing the structural integrity of buildings. Several authors have stated that the use of active desiccants enhances the quality of the indoor air by helping to maintain comfort criteria (temperature, humidity and ventilation, removing particulates and bioaerosols from the air, and removing chemical pollutants from the air. The capabilities of a rotary wheel solid-desiccant dehumidifier at removing selected IAQ-related fungal organisms from the airstream were quantified at temperatures ranging from 60°F to 360°F at 100°F intervals. Average removal efficiencies for viable concentrations of spores ranged from 42%-98% for Asrpergillus niger, Cladosporium claosporioidies, and Penicillium chrysogenum at the four temperature settings. Average removal efficiencies for total spore concentrations ranged from 30%-95% for the same organisms and temperature settings. The results of this study show that utilizing a rotating honeycomb desiccant apparatus in conjunction with conventional air conditioning can significantly reduce the airborne concentrations of IAQ-related microorganisms delivered to the indoor air.
590
$a
School code: 0230.
650
4
$a
Biology, Microbiology.
$3
1017734
650
4
$a
Engineering, Industrial.
$3
626639
650
4
$a
Engineering, Mechanical.
$3
783786
690
$a
0410
690
$a
0546
690
$a
0548
710
2
$a
Texas Tech University.
$3
1017459
773
0
$t
Dissertation Abstracts International
$g
67-04B.
790
$a
0230
790
1 0
$a
Beruvides, Mario G.,
$e
advisor
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3215627
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9077662
電子資源
11.線上閱覽_V
電子書
EB W9077662
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入