語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Mechanisms, testing, and implementat...
~
Dalhousie University (Canada).
FindBook
Google Book
Amazon
博客來
Mechanisms, testing, and implementation of bone conduction hearing: Clinical and experimental investigations.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Mechanisms, testing, and implementation of bone conduction hearing: Clinical and experimental investigations./
作者:
Majdalawieh, Osama.
面頁冊數:
195 p.
附註:
Source: Dissertation Abstracts International, Volume: 69-05, Section: B, page: 3130.
Contained By:
Dissertation Abstracts International69-05B.
標題:
Engineering, Biomedical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoeng/servlet/advanced?query=NR39090
ISBN:
9780494390900
Mechanisms, testing, and implementation of bone conduction hearing: Clinical and experimental investigations.
Majdalawieh, Osama.
Mechanisms, testing, and implementation of bone conduction hearing: Clinical and experimental investigations.
- 195 p.
Source: Dissertation Abstracts International, Volume: 69-05, Section: B, page: 3130.
Thesis (Ph.D.)--Dalhousie University (Canada), 2008.
Bone conduction (BC) hearing has been utilized as a hearing rehabilitation technology for several decades. However, BC hearing is difficult to understand, and its underlying mechanisms, compared to air conduction (AC), are still quite unclear and poorly understood. Patients with conductive hearing loss are often fitted with a bone anchored hearing aid (BahaRTM). The BahaRTM makes use of a titanium abutment, surgically implanted behind the ear into the mastoid bone, to transmit the sound by BC directly to the bone. So far, it has been almost impossible to measure skull vibrations in living subjects, since vibrations of the overlying skin do not reflect underlying skull vibrations. The main focus of this thesis is to determine the characteristics of hearing through BC using multiple experiments on live heads to enhance our understanding of BC hearing. The results presented in this thesis have both clinical and scientific implications. Measurements on different BahaRTM processors reveal that they differ in the acceleration output they can achieve with differing loads. There are significant differences in the responses of the live head, and plastic and dry skulls previously used in literature. The live head shows a smoother response, with damping of the multiple small resonances seen in the dry skulls. The Baha RTM snap coupling appears to be efficient in transmitting vibrations to the skull. In comparing AC and BC fine frequency thresholds, the overall shape in any one individual appears to be concordant, suggesting that thresholds are determined by the underlying cochlear response, and not imposed by the BC pathways or skull resonances. Skull vibrations measurements in vivo showed significant variations (15-25dB) between individuals, which could be due to individual differences in skull geometry, the skin and subcutaneous tissues, as well tension in neck muscles. Based on quantitative data from loudness matching and vibration measurements, the mastoid tip appears to be the "best" contact point for BC vibrators, and the closer the excitation position is to the cochlea, the higher the sensitivity to BC. Measurements on ten patients with mixed hearing loss show incremental benefit in the hearing threshold to fitting two BahaRTMs instead of one.
ISBN: 9780494390900Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Mechanisms, testing, and implementation of bone conduction hearing: Clinical and experimental investigations.
LDR
:03115nam 2200253 a 45
001
857052
005
20100709
008
100709s2008 ||||||||||||||||| ||eng d
020
$a
9780494390900
035
$a
(UMI)AAINR39090
035
$a
AAINR39090
040
$a
UMI
$c
UMI
100
1
$a
Majdalawieh, Osama.
$3
1023968
245
1 0
$a
Mechanisms, testing, and implementation of bone conduction hearing: Clinical and experimental investigations.
300
$a
195 p.
500
$a
Source: Dissertation Abstracts International, Volume: 69-05, Section: B, page: 3130.
502
$a
Thesis (Ph.D.)--Dalhousie University (Canada), 2008.
520
$a
Bone conduction (BC) hearing has been utilized as a hearing rehabilitation technology for several decades. However, BC hearing is difficult to understand, and its underlying mechanisms, compared to air conduction (AC), are still quite unclear and poorly understood. Patients with conductive hearing loss are often fitted with a bone anchored hearing aid (BahaRTM). The BahaRTM makes use of a titanium abutment, surgically implanted behind the ear into the mastoid bone, to transmit the sound by BC directly to the bone. So far, it has been almost impossible to measure skull vibrations in living subjects, since vibrations of the overlying skin do not reflect underlying skull vibrations. The main focus of this thesis is to determine the characteristics of hearing through BC using multiple experiments on live heads to enhance our understanding of BC hearing. The results presented in this thesis have both clinical and scientific implications. Measurements on different BahaRTM processors reveal that they differ in the acceleration output they can achieve with differing loads. There are significant differences in the responses of the live head, and plastic and dry skulls previously used in literature. The live head shows a smoother response, with damping of the multiple small resonances seen in the dry skulls. The Baha RTM snap coupling appears to be efficient in transmitting vibrations to the skull. In comparing AC and BC fine frequency thresholds, the overall shape in any one individual appears to be concordant, suggesting that thresholds are determined by the underlying cochlear response, and not imposed by the BC pathways or skull resonances. Skull vibrations measurements in vivo showed significant variations (15-25dB) between individuals, which could be due to individual differences in skull geometry, the skin and subcutaneous tissues, as well tension in neck muscles. Based on quantitative data from loudness matching and vibration measurements, the mastoid tip appears to be the "best" contact point for BC vibrators, and the closer the excitation position is to the cochlea, the higher the sensitivity to BC. Measurements on ten patients with mixed hearing loss show incremental benefit in the hearing threshold to fitting two BahaRTMs instead of one.
590
$a
School code: 0328.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Health Sciences, Audiology.
$3
1018138
690
$a
0300
690
$a
0541
710
2
$a
Dalhousie University (Canada).
$3
1017625
773
0
$t
Dissertation Abstracts International
$g
69-05B.
790
$a
0328
791
$a
Ph.D.
792
$a
2008
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoeng/servlet/advanced?query=NR39090
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9072213
電子資源
11.線上閱覽_V
電子書
EB W9072213
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入