語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Identification and characterization ...
~
The University of Texas Graduate School of Biomedical Sciences at Houston.
FindBook
Google Book
Amazon
博客來
Identification and characterization of an optimal three-dimensional dosimetry system for remote auditing by the RPC.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Identification and characterization of an optimal three-dimensional dosimetry system for remote auditing by the RPC./
作者:
Heard, Malcolm P.
面頁冊數:
147 p.
附註:
Adviser: Geoffrey Ibbott.
Contained By:
Dissertation Abstracts International70-05B.
標題:
Biophysics, Medical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3358128
ISBN:
9781109172744
Identification and characterization of an optimal three-dimensional dosimetry system for remote auditing by the RPC.
Heard, Malcolm P.
Identification and characterization of an optimal three-dimensional dosimetry system for remote auditing by the RPC.
- 147 p.
Adviser: Geoffrey Ibbott.
Thesis (Ph.D.)--The University of Texas Graduate School of Biomedical Sciences at Houston, 2009.
Advanced treatment techniques currently used in radiation treatment require the use of a dosimeter capable of performing measurements with high spatial resolution in three-dimensions. The Radiological Physics Center (RPC) evaluates an institution's ability to deliver advance treatments through the use of anthropomorphic phantoms. The phantoms currently use film dosimetry to provide two-dimensional measurements in selected planes. Therefore, the RPC has a need for a three-dimensional dosimeter. The purpose of this project was to characterize several three-dimensional dosimeters and identify a formulation best suited for use by the RPC in an anthropomorphic phantom. Two polymer gel formulations, PAGAT and BANGRTMkit, and a radiochromic dosimeter, PRESAGE(TM), were investigated in this project.
ISBN: 9781109172744Subjects--Topical Terms:
1017681
Biophysics, Medical.
Identification and characterization of an optimal three-dimensional dosimetry system for remote auditing by the RPC.
LDR
:04156nam 2200325 a 45
001
853139
005
20100701
008
100701s2009 ||||||||||||||||| ||eng d
020
$a
9781109172744
035
$a
(UMI)AAI3358128
035
$a
AAI3358128
040
$a
UMI
$c
UMI
100
1
$a
Heard, Malcolm P.
$3
1019339
245
1 0
$a
Identification and characterization of an optimal three-dimensional dosimetry system for remote auditing by the RPC.
300
$a
147 p.
500
$a
Adviser: Geoffrey Ibbott.
500
$a
Source: Dissertation Abstracts International, Volume: 70-05, Section: B, page: 2774.
502
$a
Thesis (Ph.D.)--The University of Texas Graduate School of Biomedical Sciences at Houston, 2009.
520
$a
Advanced treatment techniques currently used in radiation treatment require the use of a dosimeter capable of performing measurements with high spatial resolution in three-dimensions. The Radiological Physics Center (RPC) evaluates an institution's ability to deliver advance treatments through the use of anthropomorphic phantoms. The phantoms currently use film dosimetry to provide two-dimensional measurements in selected planes. Therefore, the RPC has a need for a three-dimensional dosimeter. The purpose of this project was to characterize several three-dimensional dosimeters and identify a formulation best suited for use by the RPC in an anthropomorphic phantom. Two polymer gel formulations, PAGAT and BANGRTMkit, and a radiochromic dosimeter, PRESAGE(TM), were investigated in this project.
520
$a
An MR imaging protocol to perform spin-spin relaxation time (T2) measurements of the polymer gels was developed. Results showed that a multi-spin echo pulse sequence with at least 32 echoes and an echo time of 9 ms should be used to minimize the dose resolution of both gel formulations. A 64-echo multi-spin echo pulse sequence with a 9 ms echo time was used to perform T2 measurements of polymer gels in this project. Temperature measurements were made in a polymer gel during imaging to ensure the gel was not being heated thereby affecting the accuracy of the T2 measurements. A maximum temperature increase of 1.2 °C was measured and found to have no effect on the T2 measurements.
520
$a
Each dosimetry formulation was characterized to determine the dose response, linearity, reproducibility, spatial stability, and dose resolution. PRESAGE dosimeters were imaged with optical computed tomography (OCT) after irradiation. Both MRI and OCT were used to identify the best-suited imaging modality for each polymer gel formulation. Established criteria for each parameter were used to evaluate each dosimeter's characteristics and to identify the dosimeter best-suited for use by the RPC. PAGAT gel imaged with OCT was identified as the dosimetry system to be used in an anthropomorphic phantom.
520
$a
A conventional and IMRT treatment plan were developed for the RPC's head and neck phantom. An insert was manufactured to accommodate a polymer gel dosimeter. PAGAT polymer gel was used to measure both treatment plans. Film measurements were also made of both treatment plans. Film was able to achieve a pass rate of at least 93% for both the conventional and IMRT treatments. Pass rates no larger than 88% were achieved with gel. The gel irradiated with the IMRT treatment measured 35% more dose than calculated by the treatment plan. The gel irradiated with the conventional treatment also over-responded in certain regions.
520
$a
The three-dimensional dosimeter is capable of providing measurements of the entire dose distribution from a single irradiation. Any plane within the distribution could be extracted from the gel measurements and compared to the treatment plan. However, PAGAT gel imaged with OCT was unable to provide comparisons with the treatment plan that are equivalent or better than those performed with film.
590
$a
School code: 2034.
650
4
$a
Biophysics, Medical.
$3
1017681
650
4
$a
Engineering, Biomedical.
$3
1017684
690
$a
0541
690
$a
0760
710
2
$a
The University of Texas Graduate School of Biomedical Sciences at Houston.
$3
1019338
773
0
$t
Dissertation Abstracts International
$g
70-05B.
790
$a
2034
790
1 0
$a
Ibbott, Geoffrey,
$e
advisor
791
$a
Ph.D.
792
$a
2009
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3358128
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9069659
電子資源
11.線上閱覽_V
電子書
EB W9069659
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入