Stress corrosion cracking of rebar r...
~
Bylapudi, Gopi.
FindBook
Google Book
Amazon
博客來
Stress corrosion cracking of rebar roof bolts in U.S. underground coal mines - A preliminary study.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Stress corrosion cracking of rebar roof bolts in U.S. underground coal mines - A preliminary study./
作者:
Bylapudi, Gopi.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2014,
面頁冊數:
127 p.
附註:
Source: Masters Abstracts International, Volume: 76-09.
Contained By:
Masters Abstracts International76-09.
標題:
Chemical engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1584809
ISBN:
9781321599626
Stress corrosion cracking of rebar roof bolts in U.S. underground coal mines - A preliminary study.
Bylapudi, Gopi.
Stress corrosion cracking of rebar roof bolts in U.S. underground coal mines - A preliminary study.
- Ann Arbor : ProQuest Dissertations & Theses, 2014 - 127 p.
Source: Masters Abstracts International, Volume: 76-09.
Thesis (M.S.)--Southern Illinois University at Carbondale, 2014.
.
According to the National Institute of Occupational Safety and Health (NIOSH), about 100 million rock anchors were installed in the USA mining industry during 1999 (Dolinar, 2000). The rock bolt usage in US coal mining industry fell from 85 million in the year 1988 to 68 million by 2005 (Tadolini, 2006), and is assumed to be close to that number of rock anchors consumed currently since, the tonnage from underground is almost the same. Most underground coal mines have conditions such as moisture in the atmosphere, ground water with different chemical contents that are conducive for corrosion of rock anchors and ancillaries (such as plates), and the effects of this on the performance of the anchors had been researched in the US to an extent from the past research at Southern Illinois University Carbondale (SIUC). In addition to the general corrosion like pitting and crevice, stress corrosion adds to the process a potentially serious threat and results in material failure underground due to stress corrosion cracking (SCC) yet the effects are not fully understood in the USA. The results of this research therefore will have a positive and direct effect on rock related safety. During this research project in situ specific tests were conducted with bolts to try and determine the corrosion potential in a specific coal-mining region. The coal mining areas were divided into three regions and were named as East, Mid-West and West respectively. To enhance the value/importance of the field data collected from the mines, a metal mine and a salt mine (two non-coal mines) were included in the plan and the data analysis proved that the methodology developed for determining the corrosion potential underground is applicable to any underground mines. The Insitu studies include water samples collection and analysis and open circuit potential (OCP/Eoc) testing and analysis. Open Circuit Potential (OCP) data were recorded to estimate probability of active corrosion. Hypothetically, probability of active corrosion is lower if the actual OCP of roof bolts in the mine is less than the characteristic OCP of the steel grade, and vice versa. The effects of certain factors such as the roof condition, reference distance (distance between bolt and reference electrode) on the open circuit potential data during the measurements were studied to ensure its impact on the corrosion potential determination technique developed. The findings from this research helps standardize the corrosion potential determination methodology. The preliminary study of stress corrosion cracking of the subject test sample (Grade 60 rebar roof bolt) was conducted in this research work. The experimental study invloves testing a complete roof bolt in the mine simulated environment. The mine simulated environment in the test cell consists of the roof strata material collected from the mine site with continuous flow of water at slower and varaible flow rate (0 to 3 ml/minute) with pH in the range of 7.5 to 9.0. The results showed that stress corrosion could be very serious problem when it comes to long term mining applications. The stress corrosion test cell developed and tested was proved to be significant in conducting the long term stress corrosion tests. The strength results of the Grade 60 rebar roof bolt tested had a significant strength loss after 3 months of testing in the stress corrosion cell. Hence, more SCC studies are deemed necessary to evaluate the seriousness of the problem and if possible eliminate it.
ISBN: 9781321599626Subjects--Topical Terms:
560457
Chemical engineering.
Subjects--Index Terms:
Corrosion
Stress corrosion cracking of rebar roof bolts in U.S. underground coal mines - A preliminary study.
LDR
:04842nmm a2200421 4500
001
2403704
005
20241125080152.5
006
m o d
007
cr#unu||||||||
008
251215s2014 ||||||||||||||||| ||eng d
020
$a
9781321599626
035
$a
(MiAaPQ)AAI1584809
035
$a
(MiAaPQ)siu:12868
035
$a
AAI1584809
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Bylapudi, Gopi.
$3
3773968
245
1 0
$a
Stress corrosion cracking of rebar roof bolts in U.S. underground coal mines - A preliminary study.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2014
300
$a
127 p.
500
$a
Source: Masters Abstracts International, Volume: 76-09.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Spearing, A.J.S;Mondal, Kanchan.
502
$a
Thesis (M.S.)--Southern Illinois University at Carbondale, 2014.
506
$a
.
520
$a
According to the National Institute of Occupational Safety and Health (NIOSH), about 100 million rock anchors were installed in the USA mining industry during 1999 (Dolinar, 2000). The rock bolt usage in US coal mining industry fell from 85 million in the year 1988 to 68 million by 2005 (Tadolini, 2006), and is assumed to be close to that number of rock anchors consumed currently since, the tonnage from underground is almost the same. Most underground coal mines have conditions such as moisture in the atmosphere, ground water with different chemical contents that are conducive for corrosion of rock anchors and ancillaries (such as plates), and the effects of this on the performance of the anchors had been researched in the US to an extent from the past research at Southern Illinois University Carbondale (SIUC). In addition to the general corrosion like pitting and crevice, stress corrosion adds to the process a potentially serious threat and results in material failure underground due to stress corrosion cracking (SCC) yet the effects are not fully understood in the USA. The results of this research therefore will have a positive and direct effect on rock related safety. During this research project in situ specific tests were conducted with bolts to try and determine the corrosion potential in a specific coal-mining region. The coal mining areas were divided into three regions and were named as East, Mid-West and West respectively. To enhance the value/importance of the field data collected from the mines, a metal mine and a salt mine (two non-coal mines) were included in the plan and the data analysis proved that the methodology developed for determining the corrosion potential underground is applicable to any underground mines. The Insitu studies include water samples collection and analysis and open circuit potential (OCP/Eoc) testing and analysis. Open Circuit Potential (OCP) data were recorded to estimate probability of active corrosion. Hypothetically, probability of active corrosion is lower if the actual OCP of roof bolts in the mine is less than the characteristic OCP of the steel grade, and vice versa. The effects of certain factors such as the roof condition, reference distance (distance between bolt and reference electrode) on the open circuit potential data during the measurements were studied to ensure its impact on the corrosion potential determination technique developed. The findings from this research helps standardize the corrosion potential determination methodology. The preliminary study of stress corrosion cracking of the subject test sample (Grade 60 rebar roof bolt) was conducted in this research work. The experimental study invloves testing a complete roof bolt in the mine simulated environment. The mine simulated environment in the test cell consists of the roof strata material collected from the mine site with continuous flow of water at slower and varaible flow rate (0 to 3 ml/minute) with pH in the range of 7.5 to 9.0. The results showed that stress corrosion could be very serious problem when it comes to long term mining applications. The stress corrosion test cell developed and tested was proved to be significant in conducting the long term stress corrosion tests. The strength results of the Grade 60 rebar roof bolt tested had a significant strength loss after 3 months of testing in the stress corrosion cell. Hence, more SCC studies are deemed necessary to evaluate the seriousness of the problem and if possible eliminate it.
590
$a
School code: 0209.
650
4
$a
Chemical engineering.
$3
560457
650
4
$a
Mining engineering.
$3
788403
650
4
$a
Mining.
$3
3544442
653
$a
Corrosion
653
$a
Corrosion potential
653
$a
Open circuit potential
653
$a
Roof bolts
653
$a
Stress corrosion cracking
653
$a
Underground coal mines
690
$a
0542
690
$a
0551
710
2
$a
Southern Illinois University at Carbondale.
$b
Mining Engineering.
$3
3773972
773
0
$t
Masters Abstracts International
$g
76-09.
790
$a
0209
791
$a
M.S.
792
$a
2014
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1584809
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9512024
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入