語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Multirate Signal Processing for Wide...
~
Sokolova, Alice.
FindBook
Google Book
Amazon
博客來
Multirate Signal Processing for Wide Dynamic Range Compression and Feedback Control in Hearing Aids.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Multirate Signal Processing for Wide Dynamic Range Compression and Feedback Control in Hearing Aids./
作者:
Sokolova, Alice.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2023,
面頁冊數:
101 p.
附註:
Source: Dissertations Abstracts International, Volume: 85-07, Section: B.
Contained By:
Dissertations Abstracts International85-07B.
標題:
Computer engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30819828
ISBN:
9798381376609
Multirate Signal Processing for Wide Dynamic Range Compression and Feedback Control in Hearing Aids.
Sokolova, Alice.
Multirate Signal Processing for Wide Dynamic Range Compression and Feedback Control in Hearing Aids.
- Ann Arbor : ProQuest Dissertations & Theses, 2023 - 101 p.
Source: Dissertations Abstracts International, Volume: 85-07, Section: B.
Thesis (Ph.D.)--San Diego State University, 2023.
This item must not be sold to any third party vendors.
Hearing loss affects millions of people in the world, and has a deep impact on quality of life. Consequences of hearing loss can include difficulty of communication, social isolation, and even an increased risk of developing dementia. While hearing loss treatment is not restorative, hearing aids aim to compensate for the hearing loss and restore audibility of sound using a combination linear and nonlinear amplification methods. One of the fundamental features of modern hearing aids is Wide Dynamic Range Compression (WDRC). Compression seeks to compensate for hearing loss by reducing the dynamic range of an audio signal and mapping the signal onto the remaining dynamic range of a hearing impaired individual, which is generally narrower than that of a normal hearing individual. Compression has been shown to improve loudness comfort, audibility, and intelligibility of sound for hearing impaired individuals, however, there remains significant user dissatisfaction with compressive hearing aids. This dissertation describes an end-to-end WDRC system which offers solutions to many ongoing hearing aid research challenges, and consists of the following subsystems: frequency decomposition, magnitude estimation, automatic gain control, feedback management, and user interface. Our system is open source and is part of a greater initiative to democratize hearing aid research.Frequency decomposition is the first stage of compression. Since hearing, whether normal or impaired, is inherently frequency dependent, different frequency components must be processed differently, necessitating frequency channelization. We designed a multirate eleven band half-octave filter bank for audiometric signal decomposition. Our filter bank surpasses other non-proprietary hearing aids, offering more channels with narrower bandwidth at lower computational cost. Our novel multirate processing structure dramatically reduces the complexity of the system by processing each channel at a sampling rate proportional to its frequency. Our multirate channelizer also enables all subsequent hearing aid processing to be performed at multiple sampling rates, reducing power consumption of the entire processing chain.The following stage of WDRC is magnitude estimation and automatic gain control. The conventional approach uses a peak detector to track a smoothed version of the signal envelope and apply gain. However, a peak detector produces an inaccurate estimate of the signal envelope with ripple. Moreover, the effects of attack and release times in hearing aids are not well explored in academic literature. We derived a closed-form solution relating attack and release time to other hearing aid parameters. Based on this derivation, we designed a highly accurate envelope detector based on the Hilbert Transform, followed by a precise automatic-gain-control algorithm yielding highly accurate dynamic performance. Central to the automatic-gain-control algorithm is the input-output transfer function, which maps input signal magnitude to output magnitude. The conventional WDRC input-output transfer function is a piece-wise segmented function, defined by four or more parameters. Conventional WDRC also overamplifies low-level signals, which reduces output signal-to-noise ratio and causes the hearing aid to sound noisy. We designed a novel curvilinear transfer function for WDRC which simplifies the parameterization of compression, reduces distortion caused by hard knee points, and improves signal-to-noise ratio by reducing amplification of low-level noisy.Lastly, a major difficulty in hearing aid research is acoustic feedback management. Adaptive filters are highly effective at cancelling feedback, however, there is a delay in their response to a change of acoustic conditions, such as a hand touching the ear, and adaptive filters may cancel useful components of the input signal as well as feedback. We designed a feedback cancellation algorithm which uses variable frequency shifting to successfully eliminate feedback in realistic hearing aid test conditions. 
ISBN: 9798381376609Subjects--Topical Terms:
621879
Computer engineering.
Subjects--Index Terms:
Feedback control
Multirate Signal Processing for Wide Dynamic Range Compression and Feedback Control in Hearing Aids.
LDR
:05338nmm a2200397 4500
001
2393270
005
20240311061626.5
006
m o d
007
cr#unu||||||||
008
251215s2023 ||||||||||||||||| ||eng d
020
$a
9798381376609
035
$a
(MiAaPQ)AAI30819828
035
$a
AAI30819828
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Sokolova, Alice.
$3
3762720
245
1 0
$a
Multirate Signal Processing for Wide Dynamic Range Compression and Feedback Control in Hearing Aids.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2023
300
$a
101 p.
500
$a
Source: Dissertations Abstracts International, Volume: 85-07, Section: B.
500
$a
Advisor: harris, fred;Aksanli, Baris.
502
$a
Thesis (Ph.D.)--San Diego State University, 2023.
506
$a
This item must not be sold to any third party vendors.
520
$a
Hearing loss affects millions of people in the world, and has a deep impact on quality of life. Consequences of hearing loss can include difficulty of communication, social isolation, and even an increased risk of developing dementia. While hearing loss treatment is not restorative, hearing aids aim to compensate for the hearing loss and restore audibility of sound using a combination linear and nonlinear amplification methods. One of the fundamental features of modern hearing aids is Wide Dynamic Range Compression (WDRC). Compression seeks to compensate for hearing loss by reducing the dynamic range of an audio signal and mapping the signal onto the remaining dynamic range of a hearing impaired individual, which is generally narrower than that of a normal hearing individual. Compression has been shown to improve loudness comfort, audibility, and intelligibility of sound for hearing impaired individuals, however, there remains significant user dissatisfaction with compressive hearing aids. This dissertation describes an end-to-end WDRC system which offers solutions to many ongoing hearing aid research challenges, and consists of the following subsystems: frequency decomposition, magnitude estimation, automatic gain control, feedback management, and user interface. Our system is open source and is part of a greater initiative to democratize hearing aid research.Frequency decomposition is the first stage of compression. Since hearing, whether normal or impaired, is inherently frequency dependent, different frequency components must be processed differently, necessitating frequency channelization. We designed a multirate eleven band half-octave filter bank for audiometric signal decomposition. Our filter bank surpasses other non-proprietary hearing aids, offering more channels with narrower bandwidth at lower computational cost. Our novel multirate processing structure dramatically reduces the complexity of the system by processing each channel at a sampling rate proportional to its frequency. Our multirate channelizer also enables all subsequent hearing aid processing to be performed at multiple sampling rates, reducing power consumption of the entire processing chain.The following stage of WDRC is magnitude estimation and automatic gain control. The conventional approach uses a peak detector to track a smoothed version of the signal envelope and apply gain. However, a peak detector produces an inaccurate estimate of the signal envelope with ripple. Moreover, the effects of attack and release times in hearing aids are not well explored in academic literature. We derived a closed-form solution relating attack and release time to other hearing aid parameters. Based on this derivation, we designed a highly accurate envelope detector based on the Hilbert Transform, followed by a precise automatic-gain-control algorithm yielding highly accurate dynamic performance. Central to the automatic-gain-control algorithm is the input-output transfer function, which maps input signal magnitude to output magnitude. The conventional WDRC input-output transfer function is a piece-wise segmented function, defined by four or more parameters. Conventional WDRC also overamplifies low-level signals, which reduces output signal-to-noise ratio and causes the hearing aid to sound noisy. We designed a novel curvilinear transfer function for WDRC which simplifies the parameterization of compression, reduces distortion caused by hard knee points, and improves signal-to-noise ratio by reducing amplification of low-level noisy.Lastly, a major difficulty in hearing aid research is acoustic feedback management. Adaptive filters are highly effective at cancelling feedback, however, there is a delay in their response to a change of acoustic conditions, such as a hand touching the ear, and adaptive filters may cancel useful components of the input signal as well as feedback. We designed a feedback cancellation algorithm which uses variable frequency shifting to successfully eliminate feedback in realistic hearing aid test conditions. 
590
$a
School code: 0220.
650
4
$a
Computer engineering.
$3
621879
650
4
$a
Audiology.
$3
537237
650
4
$a
Acoustics.
$3
879105
653
$a
Feedback control
653
$a
Hearing aids
653
$a
Audio signal
653
$a
Computational cost
653
$a
Signal envelope
690
$a
0464
690
$a
0300
690
$a
0986
710
2
$a
San Diego State University.
$b
Electrical Engineering.
$3
2101170
773
0
$t
Dissertations Abstracts International
$g
85-07B.
790
$a
0220
791
$a
Ph.D.
792
$a
2023
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=30819828
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9501590
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入