語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
The Impacts of Dynamic Solar Screens on Energy Performance and Natural Ventilation Effectiveness in Office Buildings via CFD Simulation Under Different Climatic Condition.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
The Impacts of Dynamic Solar Screens on Energy Performance and Natural Ventilation Effectiveness in Office Buildings via CFD Simulation Under Different Climatic Condition./
作者:
Mohajerzadeh, Zia.
面頁冊數:
1 online resource (116 pages)
附註:
Source: Masters Abstracts International, Volume: 84-03.
Contained By:
Masters Abstracts International84-03.
標題:
Energy. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29215429click for full text (PQDT)
ISBN:
9798841745969
The Impacts of Dynamic Solar Screens on Energy Performance and Natural Ventilation Effectiveness in Office Buildings via CFD Simulation Under Different Climatic Condition.
Mohajerzadeh, Zia.
The Impacts of Dynamic Solar Screens on Energy Performance and Natural Ventilation Effectiveness in Office Buildings via CFD Simulation Under Different Climatic Condition.
- 1 online resource (116 pages)
Source: Masters Abstracts International, Volume: 84-03.
Thesis (M.S.)--University of Oregon, 2022.
Includes bibliographical references
Architects and designers are increasingly interested in employing dynamic facades in contemporary office buildings. One of the dynamic facade types, which is widely used is a solar screen and they affect the indoor environment. This study evaluates the effect of a solar screen across a range of perforation ratios and its distance to the building on energy utilization, natural ventilation, indoor air temperature, and CO2 concentration in contemporary office buildings. Results demonstrate that dynamic solar screens have a promising positive impact on reducing energy consumption while improving indoor air quality. When these screens are in a closed state, they can reduce indoor air temperature up to 1°C and reduce energy consumption up to 60% in their most optimized state. Furthermore, the study's results show that the dynamic solar screens impact airflow inside the office space based on their different states (open, semi-open, or closed).
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9798841745969Subjects--Topical Terms:
876794
Energy.
Subjects--Index Terms:
Dynamic solar screensIndex Terms--Genre/Form:
542853
Electronic books.
The Impacts of Dynamic Solar Screens on Energy Performance and Natural Ventilation Effectiveness in Office Buildings via CFD Simulation Under Different Climatic Condition.
LDR
:02495nmm a2200433K 4500
001
2356118
005
20230612071822.5
006
m o d
007
cr mn ---uuuuu
008
241011s2022 xx obm 000 0 eng d
020
$a
9798841745969
035
$a
(MiAaPQ)AAI29215429
035
$a
AAI29215429
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Mohajerzadeh, Zia.
$3
3696588
245
1 4
$a
The Impacts of Dynamic Solar Screens on Energy Performance and Natural Ventilation Effectiveness in Office Buildings via CFD Simulation Under Different Climatic Condition.
264
0
$c
2022
300
$a
1 online resource (116 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 84-03.
500
$a
Advisor: Elzeyadi, Ihab M. K.
502
$a
Thesis (M.S.)--University of Oregon, 2022.
504
$a
Includes bibliographical references
520
$a
Architects and designers are increasingly interested in employing dynamic facades in contemporary office buildings. One of the dynamic facade types, which is widely used is a solar screen and they affect the indoor environment. This study evaluates the effect of a solar screen across a range of perforation ratios and its distance to the building on energy utilization, natural ventilation, indoor air temperature, and CO2 concentration in contemporary office buildings. Results demonstrate that dynamic solar screens have a promising positive impact on reducing energy consumption while improving indoor air quality. When these screens are in a closed state, they can reduce indoor air temperature up to 1°C and reduce energy consumption up to 60% in their most optimized state. Furthermore, the study's results show that the dynamic solar screens impact airflow inside the office space based on their different states (open, semi-open, or closed).
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Energy.
$3
876794
650
4
$a
Alternative energy.
$3
3436775
650
4
$a
Architectural engineering.
$3
3174102
650
4
$a
Fluid mechanics.
$3
528155
653
$a
Dynamic solar screens
653
$a
Energy performance
653
$a
Natural ventilation
653
$a
Office building
653
$a
Computational fluid dynamics
653
$a
Climatic condition
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0204
690
$a
0462
690
$a
0363
690
$a
0729
690
$a
0791
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
University of Oregon.
$b
Department of Architecture.
$3
2105379
773
0
$t
Masters Abstracts International
$g
84-03.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29215429
$z
click for full text (PQDT)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9478474
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入