語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
High-Speed Millimeter-Wave Active Incoherent Fourier Domain Imaging.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
High-Speed Millimeter-Wave Active Incoherent Fourier Domain Imaging./
作者:
Vakalis, Stavros.
面頁冊數:
1 online resource (171 pages)
附註:
Source: Dissertations Abstracts International, Volume: 84-02, Section: B.
Contained By:
Dissertations Abstracts International84-02B.
標題:
Electromagnetics. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29258338click for full text (PQDT)
ISBN:
9798837521843
High-Speed Millimeter-Wave Active Incoherent Fourier Domain Imaging.
Vakalis, Stavros.
High-Speed Millimeter-Wave Active Incoherent Fourier Domain Imaging.
- 1 online resource (171 pages)
Source: Dissertations Abstracts International, Volume: 84-02, Section: B.
Thesis (Ph.D.)--Michigan State University, 2022.
Includes bibliographical references
Millimeter-wave imaging is used in applications such as security screening, remote sensing, medical imaging, and non-destructive testing due to the good penetration characteristics of millimeter-wave radiation which can provide "see-through" capabilities. Electromagnetic signals in the frequency range of 30-300 GHz can penetrate easily through materials like clothing, fog, and smoke, and at the same time provide image reconstruction with fine spatial resolution. Millimeter-wave imaging is typically implemented by means of mechanical or electrical scanning which requires long data acquisition times or a large number of active components. Computational imaging can reduce both the data acquisition time and the number of active components, but this comes at the cost of heavy computational loads, which makes real-time operation challenging. Passive millimeter-wave imaging systems that capture thermal signals and operate similarly to optical cameras, are very costly because they need to employ highly sensitive receivers due to thermal radiation being extremely low power at millimeter-wave frequencies. A paradigm shift is needed in order to advance the current imaging modalities in millimeter-wave frequencies.In this dissertation, I present a newly developed millimeter-wave imaging technique called active incoherent millimeter-wave (AIM) imaging which combines the benefits of active and passive millimeter-wave imaging. This approach combines the high signal-to-noise ratio capabilities of active millimeter-wave imaging systems with the fast image formation potential of passive millimeter-wave imaging systems. The combination is achieved by illuminating the scene with multiple spatially distributed noise transmitters that mimic the randomness of thermal radiation. Because the concept of incoherent noise illumination has not been investigated thoroughly in the literature of millimeter-wave imaging, I discuss design considerations for creating a space-time incoherent transmitter and novel measurements for characterizing space-time incoherence. Starting from my earlier work in microwave frequencies, I present the system design and calibration approach, along with an experimental demonstration of a millimeter-wave active incoherent digital array. The array is capable of generating millimeter-wave video at very high frame rates, and millimeter-wave imaging results of 652 frames per second of a sphere moving in a pendulum motion are included. The scenario of using the stray reflections from a small set of communications transmitters is also examined and I present results using WiFi and fifth-generation (5G) communications signals. I also expand interferometric imaging to three dimensions using a novel pulse modulation as an envelope on the noise signals to provide differentiation along the range dimension. Prior to this work, three-dimensional interferometric millimeter-wave imaging had only been implemented in the near-field region or using three-dimensional volumetric arrays, which pose significant size and volume concerns. A new algorithm for three-dimensional interferometric image formation is presented along with simulated results and experimental measurements.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9798837521843Subjects--Topical Terms:
3173223
Electromagnetics.
Subjects--Index Terms:
IncoherenceIndex Terms--Genre/Form:
542853
Electronic books.
High-Speed Millimeter-Wave Active Incoherent Fourier Domain Imaging.
LDR
:04524nmm a2200373K 4500
001
2354747
005
20230501063909.5
006
m o d
007
cr mn ---uuuuu
008
241011s2022 xx obm 000 0 eng d
020
$a
9798837521843
035
$a
(MiAaPQ)AAI29258338
035
$a
AAI29258338
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Vakalis, Stavros.
$3
3695111
245
1 0
$a
High-Speed Millimeter-Wave Active Incoherent Fourier Domain Imaging.
264
0
$c
2022
300
$a
1 online resource (171 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 84-02, Section: B.
500
$a
Advisor: Nanzer, Jeffrey A.
502
$a
Thesis (Ph.D.)--Michigan State University, 2022.
504
$a
Includes bibliographical references
520
$a
Millimeter-wave imaging is used in applications such as security screening, remote sensing, medical imaging, and non-destructive testing due to the good penetration characteristics of millimeter-wave radiation which can provide "see-through" capabilities. Electromagnetic signals in the frequency range of 30-300 GHz can penetrate easily through materials like clothing, fog, and smoke, and at the same time provide image reconstruction with fine spatial resolution. Millimeter-wave imaging is typically implemented by means of mechanical or electrical scanning which requires long data acquisition times or a large number of active components. Computational imaging can reduce both the data acquisition time and the number of active components, but this comes at the cost of heavy computational loads, which makes real-time operation challenging. Passive millimeter-wave imaging systems that capture thermal signals and operate similarly to optical cameras, are very costly because they need to employ highly sensitive receivers due to thermal radiation being extremely low power at millimeter-wave frequencies. A paradigm shift is needed in order to advance the current imaging modalities in millimeter-wave frequencies.In this dissertation, I present a newly developed millimeter-wave imaging technique called active incoherent millimeter-wave (AIM) imaging which combines the benefits of active and passive millimeter-wave imaging. This approach combines the high signal-to-noise ratio capabilities of active millimeter-wave imaging systems with the fast image formation potential of passive millimeter-wave imaging systems. The combination is achieved by illuminating the scene with multiple spatially distributed noise transmitters that mimic the randomness of thermal radiation. Because the concept of incoherent noise illumination has not been investigated thoroughly in the literature of millimeter-wave imaging, I discuss design considerations for creating a space-time incoherent transmitter and novel measurements for characterizing space-time incoherence. Starting from my earlier work in microwave frequencies, I present the system design and calibration approach, along with an experimental demonstration of a millimeter-wave active incoherent digital array. The array is capable of generating millimeter-wave video at very high frame rates, and millimeter-wave imaging results of 652 frames per second of a sphere moving in a pendulum motion are included. The scenario of using the stray reflections from a small set of communications transmitters is also examined and I present results using WiFi and fifth-generation (5G) communications signals. I also expand interferometric imaging to three dimensions using a novel pulse modulation as an envelope on the noise signals to provide differentiation along the range dimension. Prior to this work, three-dimensional interferometric millimeter-wave imaging had only been implemented in the near-field region or using three-dimensional volumetric arrays, which pose significant size and volume concerns. A new algorithm for three-dimensional interferometric image formation is presented along with simulated results and experimental measurements.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Electromagnetics.
$3
3173223
650
4
$a
Electrical engineering.
$3
649834
653
$a
Incoherence
653
$a
Interferometry
653
$a
Millimeter-wave imaging
653
$a
Noise signals
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0607
690
$a
0544
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
Michigan State University.
$b
Electrical Engineering - Doctor of Philosophy.
$3
2094234
773
0
$t
Dissertations Abstracts International
$g
84-02B.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29258338
$z
click for full text (PQDT)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9477103
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export