Improved Distribution Feeder and Load Modeling in Power Systems Using Electro Magnetic Transient Models.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Improved Distribution Feeder and Load Modeling in Power Systems Using Electro Magnetic Transient Models./
作者:
Nekkalapu, Sameer.
面頁冊數:
1 online resource (175 pages)
附註:
Source: Dissertations Abstracts International, Volume: 84-02, Section: B.
Contained By:
Dissertations Abstracts International84-02B.
標題:
Electrical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29321360click for full text (PQDT)
ISBN:
9798841776956
Improved Distribution Feeder and Load Modeling in Power Systems Using Electro Magnetic Transient Models.
Nekkalapu, Sameer.
Improved Distribution Feeder and Load Modeling in Power Systems Using Electro Magnetic Transient Models.
- 1 online resource (175 pages)
Source: Dissertations Abstracts International, Volume: 84-02, Section: B.
Thesis (Ph.D.)--Arizona State University, 2022.
Includes bibliographical references
With the increasing penetration levels of distributed energy resources along distribution feeders, the importance of load modeling has grown significantly and therefore it is important to have an accurate representation of the distribution system in the planning and operation studies. Although, currently, most of the power system studies are being done using positive sequence commercial software packages for computational convenience purposes, it comes at the cost of reduced accuracy when compared to the more accurate electromagnetic transient (EMT) simulators (but more computationally intensive). However, it is expected, that in the next several years, the use of EMT simulators for large-scale system studies would become a necessity to implement the ambitious renewable energy targets adopted by many countries across the world. Currently, the issue of developing more accurate EMT feeder and load models has yet to be addressed. Therefore, in the first phase of this work, an optimization algorithm to synthesize an EMT distribution feeder and load model has been developed by capturing the current transients when three-phase voltage measurements (obtained from a local utility) are played-in as input, from events such as sub-transmission faults, to the synthesized model. Using the developed algorithm, for the proposed feeder model, both the load composition and the load parameters have been estimated. The synthesized load model has a load composition which includes impedance loads, single-phase induction motor (SPHIM) loads and three-phase induction motor loads. In the second phase of this work, an analytical formulation of a 24 V EMT contactor is developed to trip the air conditioner EMT SPHIM load, in the feeder and load model developed in Phase 1 of this work, under low voltage conditions. Additionally, a new methodology is developed, to estimate and incorporate the trip and reconnection settings of the proposed EMT contactor model to trip, reconnect and stall the SPHIMs in a positive sequence simulator (PSLF) for single-line to ground faults. Also, the proposed methodology has been tested on a modified three-segment three-phase feeder model using a local utility's practical feeder topological and loading information. Finally, the developed methodology is modified to accommodate three-phase faults in the system.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9798841776956Subjects--Topical Terms:
649834
Electrical engineering.
Subjects--Index Terms:
Distribution feederIndex Terms--Genre/Form:
542853
Electronic books.
Improved Distribution Feeder and Load Modeling in Power Systems Using Electro Magnetic Transient Models.
LDR
:03733nmm a2200385K 4500
001
2353941
005
20230322053943.5
006
m o d
007
cr mn ---uuuuu
008
241011s2022 xx obm 000 0 eng d
020
$a
9798841776956
035
$a
(MiAaPQ)AAI29321360
035
$a
AAI29321360
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Nekkalapu, Sameer.
$3
3694268
245
1 0
$a
Improved Distribution Feeder and Load Modeling in Power Systems Using Electro Magnetic Transient Models.
264
0
$c
2022
300
$a
1 online resource (175 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 84-02, Section: B.
500
$a
Advisor: Vittal, Vijay.
502
$a
Thesis (Ph.D.)--Arizona State University, 2022.
504
$a
Includes bibliographical references
520
$a
With the increasing penetration levels of distributed energy resources along distribution feeders, the importance of load modeling has grown significantly and therefore it is important to have an accurate representation of the distribution system in the planning and operation studies. Although, currently, most of the power system studies are being done using positive sequence commercial software packages for computational convenience purposes, it comes at the cost of reduced accuracy when compared to the more accurate electromagnetic transient (EMT) simulators (but more computationally intensive). However, it is expected, that in the next several years, the use of EMT simulators for large-scale system studies would become a necessity to implement the ambitious renewable energy targets adopted by many countries across the world. Currently, the issue of developing more accurate EMT feeder and load models has yet to be addressed. Therefore, in the first phase of this work, an optimization algorithm to synthesize an EMT distribution feeder and load model has been developed by capturing the current transients when three-phase voltage measurements (obtained from a local utility) are played-in as input, from events such as sub-transmission faults, to the synthesized model. Using the developed algorithm, for the proposed feeder model, both the load composition and the load parameters have been estimated. The synthesized load model has a load composition which includes impedance loads, single-phase induction motor (SPHIM) loads and three-phase induction motor loads. In the second phase of this work, an analytical formulation of a 24 V EMT contactor is developed to trip the air conditioner EMT SPHIM load, in the feeder and load model developed in Phase 1 of this work, under low voltage conditions. Additionally, a new methodology is developed, to estimate and incorporate the trip and reconnection settings of the proposed EMT contactor model to trip, reconnect and stall the SPHIMs in a positive sequence simulator (PSLF) for single-line to ground faults. Also, the proposed methodology has been tested on a modified three-segment three-phase feeder model using a local utility's practical feeder topological and loading information. Finally, the developed methodology is modified to accommodate three-phase faults in the system.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Electromagnetics.
$3
3173223
650
4
$a
Systems science.
$3
3168411
653
$a
Distribution feeder
653
$a
Load modeling
653
$a
Power system
653
$a
Electro magnetic transient model
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0544
690
$a
0607
690
$a
0790
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
Arizona State University.
$b
Electrical Engineering.
$3
1671741
773
0
$t
Dissertations Abstracts International
$g
84-02B.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29321360
$z
click for full text (PQDT)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9476297
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入