語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
Seismic Performance Design Criteria of Existing Bridge Bent Plastic Hinge Region and Rapid Repair Measures of Earthquake Damaged Bridges Considering Future Resilience.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Seismic Performance Design Criteria of Existing Bridge Bent Plastic Hinge Region and Rapid Repair Measures of Earthquake Damaged Bridges Considering Future Resilience./
作者:
Murtuz, A. K. M. Golam.
面頁冊數:
1 online resource (329 pages)
附註:
Source: Dissertations Abstracts International, Volume: 83-09, Section: B.
Contained By:
Dissertations Abstracts International83-09B.
標題:
Civil engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28967466click for full text (PQDT)
ISBN:
9798209908364
Seismic Performance Design Criteria of Existing Bridge Bent Plastic Hinge Region and Rapid Repair Measures of Earthquake Damaged Bridges Considering Future Resilience.
Murtuz, A. K. M. Golam.
Seismic Performance Design Criteria of Existing Bridge Bent Plastic Hinge Region and Rapid Repair Measures of Earthquake Damaged Bridges Considering Future Resilience.
- 1 online resource (329 pages)
Source: Dissertations Abstracts International, Volume: 83-09, Section: B.
Thesis (Ph.D.)--Portland State University, 2022.
Includes bibliographical references
The main objective of this research was to evaluate the seismic performance of existing sub-standard reinforced concrete (RC) bridge column-spread footing subassemblies and to quantify the material strain limits through a full-scale experimental program. A total of six column-footing test specimens with pre-1990 construction details were subjected to reverse cyclic lateral loading, utilizing a conventional three-cycle symmetric loading protocol and a protocol representing the demands expected from a CSZ earthquake. Additionally, the tests were designed so that variable axial loading could be applied to simulate the secondary load effects experienced during an earthquake in a column that is part of a multi-column bent. Despite having sub-standard seismic detailing, all the test specimens with moderate lap splice length or continuous rebar demonstrated a ductile response, reaching a minimum displacement ductility of μ = 5.4. The surprisingly ductile response can be attributed to the moderate splice length that ensured flexural plastic hinging and the low longitudinal steel ratio that resulted in significant rocking at the column-footing interface. Furthermore, flexural cracking of the accompanying spread footing and splice failure of the column dowel bars were also observed for specimens having different reinforcing and splice details. The performance of these test specimens was evaluated in terms of global and local deformation quantities, i.e., hysteretic load-deformation response, measured strains, flexural curvature profiles, etc. Finally, the experimentally obtained strain values at different damage states were used to define probabilistic operational and life safety performance criteria for seismic evaluation of the representative bridge bents. The spread of plasticity was also examined with respect to the existing plastic hinge model to be used for limit state evaluation.A rapid repair method incorporating semi-permanent installation was also developed, anticipating the need for quick measures following the Cascadia Subduction Zone (CSZ) earthquake, which is expected to damage the existing bridges in the Pacific Northwest and spread geographically throughout the region. While the conventional repair methods are effective in restoring the strength in the damaged zones, often lead to higher stiffness and strength that would likely result in shifting the failure to other parts of the structure under future earthquake or aftershock demands. The proposed repair methodology uses capacity design principles to protect the remainder of the bridge from future earthquakes and eradicates the need for establishing rebar continuity, resulting in a less labor-intensive repair method. The adopted concept is to utilize U-shaped metallic plates as externally attached ductile fuses to be anchored to the non-damaged part of the column, hence bypassing the damaged zone to restore the lateral capacity. The damaged zone can then be repaired with strips of fiber-reinforced polymer (FRP) sheets to provide lateral confinement, preventing any further damage to the core concrete. A typical substandard reinforced concrete column-to-footing subassembly was damaged during a full-scale cyclic test under the CSZ loading protocol. The column was then repaired following the rapid repair methodology and retested to achieve the as-built column lateral capacity and self-centering behavior. Results showed the potential of this methodology to restore the lateral capacity while protecting the remainder of the column from any further damage. The targeted self-centering behavior was also evident under the applied axial load. Development of the repair methodology, analytical design approach, and results from a full-scale cyclic test validating the performance of seismically substandard concrete bridge substructure is presented in this dissertation.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9798209908364Subjects--Topical Terms:
860360
Civil engineering.
Subjects--Index Terms:
Dissipative controlled rockingIndex Terms--Genre/Form:
542853
Electronic books.
Seismic Performance Design Criteria of Existing Bridge Bent Plastic Hinge Region and Rapid Repair Measures of Earthquake Damaged Bridges Considering Future Resilience.
LDR
:05465nmm a2200421K 4500
001
2353885
005
20230322053929.5
006
m o d
007
cr mn ---uuuuu
008
241011s2022 xx obm 000 0 eng d
020
$a
9798209908364
035
$a
(MiAaPQ)AAI28967466
035
$a
AAI28967466
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Murtuz, A. K. M. Golam.
$3
3694216
245
1 0
$a
Seismic Performance Design Criteria of Existing Bridge Bent Plastic Hinge Region and Rapid Repair Measures of Earthquake Damaged Bridges Considering Future Resilience.
264
0
$c
2022
300
$a
1 online resource (329 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 83-09, Section: B.
500
$a
Advisor: Dusicka, Peter.
502
$a
Thesis (Ph.D.)--Portland State University, 2022.
504
$a
Includes bibliographical references
520
$a
The main objective of this research was to evaluate the seismic performance of existing sub-standard reinforced concrete (RC) bridge column-spread footing subassemblies and to quantify the material strain limits through a full-scale experimental program. A total of six column-footing test specimens with pre-1990 construction details were subjected to reverse cyclic lateral loading, utilizing a conventional three-cycle symmetric loading protocol and a protocol representing the demands expected from a CSZ earthquake. Additionally, the tests were designed so that variable axial loading could be applied to simulate the secondary load effects experienced during an earthquake in a column that is part of a multi-column bent. Despite having sub-standard seismic detailing, all the test specimens with moderate lap splice length or continuous rebar demonstrated a ductile response, reaching a minimum displacement ductility of μ = 5.4. The surprisingly ductile response can be attributed to the moderate splice length that ensured flexural plastic hinging and the low longitudinal steel ratio that resulted in significant rocking at the column-footing interface. Furthermore, flexural cracking of the accompanying spread footing and splice failure of the column dowel bars were also observed for specimens having different reinforcing and splice details. The performance of these test specimens was evaluated in terms of global and local deformation quantities, i.e., hysteretic load-deformation response, measured strains, flexural curvature profiles, etc. Finally, the experimentally obtained strain values at different damage states were used to define probabilistic operational and life safety performance criteria for seismic evaluation of the representative bridge bents. The spread of plasticity was also examined with respect to the existing plastic hinge model to be used for limit state evaluation.A rapid repair method incorporating semi-permanent installation was also developed, anticipating the need for quick measures following the Cascadia Subduction Zone (CSZ) earthquake, which is expected to damage the existing bridges in the Pacific Northwest and spread geographically throughout the region. While the conventional repair methods are effective in restoring the strength in the damaged zones, often lead to higher stiffness and strength that would likely result in shifting the failure to other parts of the structure under future earthquake or aftershock demands. The proposed repair methodology uses capacity design principles to protect the remainder of the bridge from future earthquakes and eradicates the need for establishing rebar continuity, resulting in a less labor-intensive repair method. The adopted concept is to utilize U-shaped metallic plates as externally attached ductile fuses to be anchored to the non-damaged part of the column, hence bypassing the damaged zone to restore the lateral capacity. The damaged zone can then be repaired with strips of fiber-reinforced polymer (FRP) sheets to provide lateral confinement, preventing any further damage to the core concrete. A typical substandard reinforced concrete column-to-footing subassembly was damaged during a full-scale cyclic test under the CSZ loading protocol. The column was then repaired following the rapid repair methodology and retested to achieve the as-built column lateral capacity and self-centering behavior. Results showed the potential of this methodology to restore the lateral capacity while protecting the remainder of the column from any further damage. The targeted self-centering behavior was also evident under the applied axial load. Development of the repair methodology, analytical design approach, and results from a full-scale cyclic test validating the performance of seismically substandard concrete bridge substructure is presented in this dissertation.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Civil engineering.
$3
860360
650
4
$a
Engineering.
$3
586835
650
4
$a
Transportation.
$3
555912
650
4
$a
Geophysics.
$3
535228
653
$a
Dissipative controlled rocking
653
$a
Performance based seismic design
653
$a
Rapid and resilient repair
653
$a
Seismic performance of bridges
653
$a
Strain limit state
653
$a
Subduction earthquake
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0543
690
$a
0537
690
$a
0709
690
$a
0467
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
Portland State University.
$b
Civil and Environmental Engineering.
$3
3169102
773
0
$t
Dissertations Abstracts International
$g
83-09B.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28967466
$z
click for full text (PQDT)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9476241
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入