語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
Laboratory Examination of Lead Weights Harvested from Pitcher Pumps in Eastern Madagascar.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Laboratory Examination of Lead Weights Harvested from Pitcher Pumps in Eastern Madagascar./
作者:
Wilson, Madelyn.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2022,
面頁冊數:
137 p.
附註:
Source: Masters Abstracts International, Volume: 83-05.
Contained By:
Masters Abstracts International83-05.
標題:
Environmental engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28774901
ISBN:
9798496509183
Laboratory Examination of Lead Weights Harvested from Pitcher Pumps in Eastern Madagascar.
Wilson, Madelyn.
Laboratory Examination of Lead Weights Harvested from Pitcher Pumps in Eastern Madagascar.
- Ann Arbor : ProQuest Dissertations & Theses, 2022 - 137 p.
Source: Masters Abstracts International, Volume: 83-05.
Thesis (M.S.E.V.)--University of South Florida, 2022.
This item must not be sold to any third party vendors.
Previous sampling campaigns in Tamatave, Madagascar, conducted by the University of South Florida (USF) have identified lead contamination in drinking water sourced from self-supply pitcher pumps. The pitcher pump piston and foot valves were identified as the primary source of lead contamination since they are often manufactured from recycled lead acid batteries. The previous field sampling technique consisted of collecting an aliquot of a 10-15-liter composite sample from the pitcher pump for dissolved lead analysis; however, this technique (1) neglects the contribution of particulate lead, (2) does not properly account for the effects of water stagnation inside the pitcher pump chamber, and (3) dilutes the sample which stagnates in the pump chamber. This sampling technique is referred to as the "First-draw composite (FDC)" throughout this research. A true first draw sample represents the water which stagnates overnight within the pump chamber and predicts the maximum possible dissolved lead concentration exposure. To determine the extent to which this FDC sampling technique underestimates the true first draw sample, this research utilizes laboratory batch stagnation and column flushing studies on harvested pitcher pump foot valves. For the eight batch stagnation trials completed through this research, three different solutions with varying water quality were evaluated. A total of six column flushing trials were performed using two different solutions. Both total and dissolved lead samples (n=548) were collected for analysis using Atomic Absorption Spectroscopy. Stagnation of the foot valves demonstrated that aqueous lead concentrations increase with time as 24 h total lead concentrations were higher than 0.5 h total lead concentrations in 87% of the trials. The average particulate lead concentrations observed in the batch study for stagnation periods 0.5, 8, and 24 h were 100 μg/L, 172 μg/L, and 165 μg/L respectively and the particulate lead contribution was significantly greater than the World Health Organization guideline of 10 μg/L across all stagnation trials. Particulate lead concentrations also varied throughout the column flushing study and were typically the highest during the first 100 mL flushed as column flow was likely not great enough to dislodge any additional particulates through continued flushing. Using the obtained first draw and composite samples from the column flushing studies, this research estimates that the previous field sampling technique diluted first draw samples by 3-50 times dilution. This research shows that the prior field events likely underestimated the maximum total lead concentrations of first draw samples by neglecting the particulate lead contribution and by underestimating stagnation effects. This has important health implications for human lead exposure as water collectors who used pitcher pumps after prolonged stagnation periods may be exposed to higher water lead levels.
ISBN: 9798496509183Subjects--Topical Terms:
548583
Environmental engineering.
Subjects--Index Terms:
Contamination
Laboratory Examination of Lead Weights Harvested from Pitcher Pumps in Eastern Madagascar.
LDR
:04093nmm a2200361 4500
001
2348174
005
20220908122952.5
008
241004s2022 ||||||||||||||||| ||eng d
020
$a
9798496509183
035
$a
(MiAaPQ)AAI28774901
035
$a
AAI28774901
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Wilson, Madelyn.
$3
3687494
245
1 0
$a
Laboratory Examination of Lead Weights Harvested from Pitcher Pumps in Eastern Madagascar.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2022
300
$a
137 p.
500
$a
Source: Masters Abstracts International, Volume: 83-05.
500
$a
Advisor: Alfredo, Katherine.
502
$a
Thesis (M.S.E.V.)--University of South Florida, 2022.
506
$a
This item must not be sold to any third party vendors.
520
$a
Previous sampling campaigns in Tamatave, Madagascar, conducted by the University of South Florida (USF) have identified lead contamination in drinking water sourced from self-supply pitcher pumps. The pitcher pump piston and foot valves were identified as the primary source of lead contamination since they are often manufactured from recycled lead acid batteries. The previous field sampling technique consisted of collecting an aliquot of a 10-15-liter composite sample from the pitcher pump for dissolved lead analysis; however, this technique (1) neglects the contribution of particulate lead, (2) does not properly account for the effects of water stagnation inside the pitcher pump chamber, and (3) dilutes the sample which stagnates in the pump chamber. This sampling technique is referred to as the "First-draw composite (FDC)" throughout this research. A true first draw sample represents the water which stagnates overnight within the pump chamber and predicts the maximum possible dissolved lead concentration exposure. To determine the extent to which this FDC sampling technique underestimates the true first draw sample, this research utilizes laboratory batch stagnation and column flushing studies on harvested pitcher pump foot valves. For the eight batch stagnation trials completed through this research, three different solutions with varying water quality were evaluated. A total of six column flushing trials were performed using two different solutions. Both total and dissolved lead samples (n=548) were collected for analysis using Atomic Absorption Spectroscopy. Stagnation of the foot valves demonstrated that aqueous lead concentrations increase with time as 24 h total lead concentrations were higher than 0.5 h total lead concentrations in 87% of the trials. The average particulate lead concentrations observed in the batch study for stagnation periods 0.5, 8, and 24 h were 100 μg/L, 172 μg/L, and 165 μg/L respectively and the particulate lead contribution was significantly greater than the World Health Organization guideline of 10 μg/L across all stagnation trials. Particulate lead concentrations also varied throughout the column flushing study and were typically the highest during the first 100 mL flushed as column flow was likely not great enough to dislodge any additional particulates through continued flushing. Using the obtained first draw and composite samples from the column flushing studies, this research estimates that the previous field sampling technique diluted first draw samples by 3-50 times dilution. This research shows that the prior field events likely underestimated the maximum total lead concentrations of first draw samples by neglecting the particulate lead contribution and by underestimating stagnation effects. This has important health implications for human lead exposure as water collectors who used pitcher pumps after prolonged stagnation periods may be exposed to higher water lead levels.
590
$a
School code: 0206.
650
4
$a
Environmental engineering.
$3
548583
650
4
$a
Pumps.
$3
3687495
650
4
$a
Drinking water.
$3
605014
650
4
$a
Lead content.
$3
3687496
650
4
$a
Water pollution.
$3
3299586
650
4
$a
Water resources management.
$3
794747
653
$a
Contamination
653
$a
Drinking water
653
$a
Flushing
653
$a
Self-supply
653
$a
Stagnation
690
$a
0775
690
$a
0595
710
2
$a
University of South Florida.
$b
Civil and Environmental Engineering.
$3
1680496
773
0
$t
Masters Abstracts International
$g
83-05.
790
$a
0206
791
$a
M.S.E.V.
792
$a
2022
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28774901
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9470612
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入