語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
Development of High-speed Photoacoustic Imaging technology and Its Applications in Biomedical Research.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Development of High-speed Photoacoustic Imaging technology and Its Applications in Biomedical Research./
作者:
He, Yun .
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2019,
面頁冊數:
84 p.
附註:
Source: Dissertations Abstracts International, Volume: 81-08, Section: B.
Contained By:
Dissertations Abstracts International81-08B.
標題:
Biomedical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=27669692
ISBN:
9781392833308
Development of High-speed Photoacoustic Imaging technology and Its Applications in Biomedical Research.
He, Yun .
Development of High-speed Photoacoustic Imaging technology and Its Applications in Biomedical Research.
- Ann Arbor : ProQuest Dissertations & Theses, 2019 - 84 p.
Source: Dissertations Abstracts International, Volume: 81-08, Section: B.
Thesis (Ph.D.)--Washington University in St. Louis, 2019.
This item must not be sold to any third party vendors.
Photoacoustic (PA) tomography (PAT) is a novel imaging modality that combines the fine lateral resolution from optical imaging and the deep penetration from ultrasonic imaging, and provides rich optical-absorption-based images. PAT has been widely used in extracting structural and functional information from both ex vivo tissue samples to in vivo animals and humans with different length scales by imaging various endogenous and exogenous contrasts at the ultraviolet to infrared spectrum. For example, hemoglobin in red blood cells is of particular interest in PAT since it is one of the dominant absorbers in tissue at the visible wavelength.The main focus of this dissertation is to develop high-speed PA microscopy (PAM) technologies. Novel optical scanning, ultrasonic detection, and laser source techniques are introduced in this dissertation to advance the performance of PAM systems. These upgrades open up new avenues for PAM to be applicable to address important biomedical challenges and enable fundamental physiological studies.First, we investigated the feasibility of applying high-speed PAM to the detection and imaging of circulating tumor cells (CTCs) in melanoma models, which can provide valuable information about a tumor's metastasis potentials. We probed the melanoma CTCs at the near-infrared wavelength of 1064 nm, where the melanosomes absorb more strongly than hemoglobin. Our high-speed PA flow cytography system successfully imaged melanoma CTCs in travelling trunk vessels. We also developed a concurrent laser therapy device, hardware-triggered by the CTC signal, to photothermally lyse the CTC on the spot in an effort to inhibit metastasis.Next, we addressed the detection sensitivity issue in the previous study. We employed the stimulated Raman scattering (SRS) effect to construct a high-repetition-rate Raman laser at 658 nm, where the contrast between a melanoma CTC and the blood background is near the highest. Our upgraded PA flow cytography successfully captured sequential images of CTCs in mouse melanoma xenograft model, with a significantly improved contrast-to-noise ratio compared to our previous results. This technology is readily translatable to the clinics to extract the information of a tumor's metastasis risks.We extended the Raman laser technology to the field of brain functional studies. We developed a MEMS (micro-electromechanical systems) scanner for fast optical scanning, and incorporated it to a dual-wavelength functional PAM (fPAM) for high-speed imaging of cerebral hemodynamics in mouse. This fPAM system successfully imaged transient changes in blood oxygenation at cerebral micro-vessels in response to brief somatic stimulations. This fPAM technology is a powerful tool for neurological studies.Finally, we explored some approaches of reducing the size the PAM imaging head in an effort to translate our work to the field of wearable biometric monitors. To miniaturize the ultrasonic detection device, we fabricated a thin-film optically transparent piezoelectric detector for detecting PA waves. This technology could enable longitudinal studies on free-moving animals through a wearable version of PAM.
ISBN: 9781392833308Subjects--Topical Terms:
535387
Biomedical engineering.
Subjects--Index Terms:
Circulating tumor cell
Development of High-speed Photoacoustic Imaging technology and Its Applications in Biomedical Research.
LDR
:04379nmm a2200373 4500
001
2348034
005
20220906075148.5
008
241004s2019 ||||||||||||||||| ||eng d
020
$a
9781392833308
035
$a
(MiAaPQ)AAI27669692
035
$a
AAI27669692
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
He, Yun .
$0
(orcid)0000-0001-8430-6370
$3
3687354
245
1 0
$a
Development of High-speed Photoacoustic Imaging technology and Its Applications in Biomedical Research.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
84 p.
500
$a
Source: Dissertations Abstracts International, Volume: 81-08, Section: B.
500
$a
Advisor: Zhu, Quing;Wang, Lihong V.
502
$a
Thesis (Ph.D.)--Washington University in St. Louis, 2019.
506
$a
This item must not be sold to any third party vendors.
520
$a
Photoacoustic (PA) tomography (PAT) is a novel imaging modality that combines the fine lateral resolution from optical imaging and the deep penetration from ultrasonic imaging, and provides rich optical-absorption-based images. PAT has been widely used in extracting structural and functional information from both ex vivo tissue samples to in vivo animals and humans with different length scales by imaging various endogenous and exogenous contrasts at the ultraviolet to infrared spectrum. For example, hemoglobin in red blood cells is of particular interest in PAT since it is one of the dominant absorbers in tissue at the visible wavelength.The main focus of this dissertation is to develop high-speed PA microscopy (PAM) technologies. Novel optical scanning, ultrasonic detection, and laser source techniques are introduced in this dissertation to advance the performance of PAM systems. These upgrades open up new avenues for PAM to be applicable to address important biomedical challenges and enable fundamental physiological studies.First, we investigated the feasibility of applying high-speed PAM to the detection and imaging of circulating tumor cells (CTCs) in melanoma models, which can provide valuable information about a tumor's metastasis potentials. We probed the melanoma CTCs at the near-infrared wavelength of 1064 nm, where the melanosomes absorb more strongly than hemoglobin. Our high-speed PA flow cytography system successfully imaged melanoma CTCs in travelling trunk vessels. We also developed a concurrent laser therapy device, hardware-triggered by the CTC signal, to photothermally lyse the CTC on the spot in an effort to inhibit metastasis.Next, we addressed the detection sensitivity issue in the previous study. We employed the stimulated Raman scattering (SRS) effect to construct a high-repetition-rate Raman laser at 658 nm, where the contrast between a melanoma CTC and the blood background is near the highest. Our upgraded PA flow cytography successfully captured sequential images of CTCs in mouse melanoma xenograft model, with a significantly improved contrast-to-noise ratio compared to our previous results. This technology is readily translatable to the clinics to extract the information of a tumor's metastasis risks.We extended the Raman laser technology to the field of brain functional studies. We developed a MEMS (micro-electromechanical systems) scanner for fast optical scanning, and incorporated it to a dual-wavelength functional PAM (fPAM) for high-speed imaging of cerebral hemodynamics in mouse. This fPAM system successfully imaged transient changes in blood oxygenation at cerebral micro-vessels in response to brief somatic stimulations. This fPAM technology is a powerful tool for neurological studies.Finally, we explored some approaches of reducing the size the PAM imaging head in an effort to translate our work to the field of wearable biometric monitors. To miniaturize the ultrasonic detection device, we fabricated a thin-film optically transparent piezoelectric detector for detecting PA waves. This technology could enable longitudinal studies on free-moving animals through a wearable version of PAM.
590
$a
School code: 0252.
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Acoustics.
$3
879105
650
4
$a
Optics.
$3
517925
653
$a
Circulating tumor cell
653
$a
Functional imaging
653
$a
Imaging
653
$a
Microscopy
653
$a
Photoacoustics
690
$a
0541
690
$a
0986
690
$a
0752
710
2
$a
Washington University in St. Louis.
$b
Biomedical Engineering.
$3
1669544
773
0
$t
Dissertations Abstracts International
$g
81-08B.
790
$a
0252
791
$a
Ph.D.
792
$a
2019
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=27669692
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9470472
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入