語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
The lightning rod as a danger
~
Meppelink, Jan.
FindBook
Google Book
Amazon
博客來
The lightning rod as a danger
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
The lightning rod as a danger/ by Jan Meppelink.
作者:
Meppelink, Jan.
出版者:
Cham :Springer Nature Switzerland : : 2023.,
面頁冊數:
xxix, 211 p. :ill. (chiefly color), digital ;24 cm.
內容註:
Introduction -- Model for calculating the hazard -- Exemplary buildings with earthing system type A and type B -- Permissible limits for the cause of death due to ventricular fibrillation -- Materials -- Danger from lightning currents 10/350, 1/200; 0.25/100 according to type of coupling -- Effect of site insulation with asphalt according to IEC 62305-3 -- Effect of site insulation with gravel according to IEC 62305-3 -- Water-permeable site insulation -- Danger due to step voltage -- Summary of the hazard posed by a lightning rod -- Measures to reduce step and touch voltage as per IEC 62305-3 -- Insulating down conductor -- National and international statistics of deaths and injuries -- Statistics of relevant parameters of lightning -- Calculation of risk RA for death and injury of living beings due to electric shock as a result of touch- and step voltages according to IEC 62305-2 -- Strength of air gaps at inductively coupled surge voltages -- Numeric calculation -- Applied pulse shapes 0.25/100 according to IEC 62305-1 -- Propagation and velocity of surface discharges -- Annex A: A contribution to the limitation of step voltages -- Bibliography.
Contained By:
Springer Nature eBook
標題:
Lightning rods - Safety measures. -
電子資源:
https://doi.org/10.1007/978-3-031-30434-7
ISBN:
9783031304347
The lightning rod as a danger
Meppelink, Jan.
The lightning rod as a danger
[electronic resource] /by Jan Meppelink. - Cham :Springer Nature Switzerland :2023. - xxix, 211 p. :ill. (chiefly color), digital ;24 cm.
Introduction -- Model for calculating the hazard -- Exemplary buildings with earthing system type A and type B -- Permissible limits for the cause of death due to ventricular fibrillation -- Materials -- Danger from lightning currents 10/350, 1/200; 0.25/100 according to type of coupling -- Effect of site insulation with asphalt according to IEC 62305-3 -- Effect of site insulation with gravel according to IEC 62305-3 -- Water-permeable site insulation -- Danger due to step voltage -- Summary of the hazard posed by a lightning rod -- Measures to reduce step and touch voltage as per IEC 62305-3 -- Insulating down conductor -- National and international statistics of deaths and injuries -- Statistics of relevant parameters of lightning -- Calculation of risk RA for death and injury of living beings due to electric shock as a result of touch- and step voltages according to IEC 62305-2 -- Strength of air gaps at inductively coupled surge voltages -- Numeric calculation -- Applied pulse shapes 0.25/100 according to IEC 62305-1 -- Propagation and velocity of surface discharges -- Annex A: A contribution to the limitation of step voltages -- Bibliography.
This book investigates the physical effects of a lightning flash on a person near the down conductor of a lightning protection system. These effects are the touch voltage, the step voltage and the side flash. For this purpose, a full-scale simulation model of the human body with a resistance of 1000 ohms was first created. In the simulation model, the body can touch the down conductor or be placed close to it. Furthermore, the specific resistance of the earth is varied. Likewise, insulating layers such as asphalt can be incorporated into the simulation model. Also, special cases like water permeable layers or water layers on an asphalt layer can be calculated. In post-processing, all relevant values can be determined, such as the energy converted in the body, the charge, the current and the voltage applied to the body. A comparison with the permissible limit values then shows for the lightning protection classes whether there is danger or not and provides information on necessary measures. There is a risk for death and injury if the down conductor is touched. However, there is also a risk of a side flash if a person is standing next to a discharge. Site isolation with dry asphalt is effective, but there is a residual risk of surface discharges. In real situations with wet asphalt, water-permeable layers or asphalt with a water layer, however, there is a great risk of death or injury. Equipotential bonding with an earthing grid is a necessary but not sufficient solution with regard to the induced voltage at negative subsequent stroke. Therefore, the situation must always be examined on a case-by-case basis with regard to the safety requirements. The only effective measure to prevent injury and death due to touch voltage is an insulating down conductor in conjunction with equipotential bonding. The measures for reducing the touch voltage, such as site insulation and equipotential bonding, basically also apply to limiting the step voltage. A risk calculation according to IEC 62305-2 gives the mean time between two events of injury and death MG = 1/RA. The tolerable risk is: RA = 0,0001 or MT = 10.000 years, equivalent to one death in 10.000 years.
ISBN: 9783031304347
Standard No.: 10.1007/978-3-031-30434-7doiSubjects--Topical Terms:
3661876
Lightning rods
--Safety measures.
LC Class. No.: TH9057
Dewey Class. No.: 693.898
The lightning rod as a danger
LDR
:04295nmm a2200325 a 4500
001
2332203
003
DE-He213
005
20230613131338.0
006
m d
007
cr nn 008maaau
008
240402s2023 sz s 0 eng d
020
$a
9783031304347
$q
(electronic bk.)
020
$a
9783031304330
$q
(paper)
024
7
$a
10.1007/978-3-031-30434-7
$2
doi
035
$a
978-3-031-30434-7
040
$a
GP
$c
GP
041
1
$a
eng
$h
ger
050
4
$a
TH9057
072
7
$a
THR
$2
bicssc
072
7
$a
TEC031000
$2
bisacsh
072
7
$a
THR
$2
thema
082
0 4
$a
693.898
$2
23
090
$a
TH9057
$b
.M551 2023
100
1
$a
Meppelink, Jan.
$3
3661875
245
1 4
$a
The lightning rod as a danger
$h
[electronic resource] /
$c
by Jan Meppelink.
260
$a
Cham :
$b
Springer Nature Switzerland :
$b
Imprint: Springer,
$c
2023.
300
$a
xxix, 211 p. :
$b
ill. (chiefly color), digital ;
$c
24 cm.
505
0
$a
Introduction -- Model for calculating the hazard -- Exemplary buildings with earthing system type A and type B -- Permissible limits for the cause of death due to ventricular fibrillation -- Materials -- Danger from lightning currents 10/350, 1/200; 0.25/100 according to type of coupling -- Effect of site insulation with asphalt according to IEC 62305-3 -- Effect of site insulation with gravel according to IEC 62305-3 -- Water-permeable site insulation -- Danger due to step voltage -- Summary of the hazard posed by a lightning rod -- Measures to reduce step and touch voltage as per IEC 62305-3 -- Insulating down conductor -- National and international statistics of deaths and injuries -- Statistics of relevant parameters of lightning -- Calculation of risk RA for death and injury of living beings due to electric shock as a result of touch- and step voltages according to IEC 62305-2 -- Strength of air gaps at inductively coupled surge voltages -- Numeric calculation -- Applied pulse shapes 0.25/100 according to IEC 62305-1 -- Propagation and velocity of surface discharges -- Annex A: A contribution to the limitation of step voltages -- Bibliography.
520
$a
This book investigates the physical effects of a lightning flash on a person near the down conductor of a lightning protection system. These effects are the touch voltage, the step voltage and the side flash. For this purpose, a full-scale simulation model of the human body with a resistance of 1000 ohms was first created. In the simulation model, the body can touch the down conductor or be placed close to it. Furthermore, the specific resistance of the earth is varied. Likewise, insulating layers such as asphalt can be incorporated into the simulation model. Also, special cases like water permeable layers or water layers on an asphalt layer can be calculated. In post-processing, all relevant values can be determined, such as the energy converted in the body, the charge, the current and the voltage applied to the body. A comparison with the permissible limit values then shows for the lightning protection classes whether there is danger or not and provides information on necessary measures. There is a risk for death and injury if the down conductor is touched. However, there is also a risk of a side flash if a person is standing next to a discharge. Site isolation with dry asphalt is effective, but there is a residual risk of surface discharges. In real situations with wet asphalt, water-permeable layers or asphalt with a water layer, however, there is a great risk of death or injury. Equipotential bonding with an earthing grid is a necessary but not sufficient solution with regard to the induced voltage at negative subsequent stroke. Therefore, the situation must always be examined on a case-by-case basis with regard to the safety requirements. The only effective measure to prevent injury and death due to touch voltage is an insulating down conductor in conjunction with equipotential bonding. The measures for reducing the touch voltage, such as site insulation and equipotential bonding, basically also apply to limiting the step voltage. A risk calculation according to IEC 62305-2 gives the mean time between two events of injury and death MG = 1/RA. The tolerable risk is: RA = 0,0001 or MT = 10.000 years, equivalent to one death in 10.000 years.
650
0
$a
Lightning rods
$x
Safety measures.
$3
3661876
650
1 4
$a
Electrical Power Engineering.
$3
3592498
650
2 4
$a
Biological and Physical Engineering.
$3
3626015
650
2 4
$a
Natural Hazards.
$3
1005730
710
2
$a
SpringerLink (Online service)
$3
836513
773
0
$t
Springer Nature eBook
856
4 0
$u
https://doi.org/10.1007/978-3-031-30434-7
950
$a
Energy (SpringerNature-40367)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9458408
電子資源
11.線上閱覽_V
電子書
EB TH9057
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入