語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Attachment ventilation theory
~
Li, Angui.
FindBook
Google Book
Amazon
博客來
Attachment ventilation theory
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Attachment ventilation theory/ by Angui Li.
作者:
Li, Angui.
出版者:
Singapore :Springer Nature Singapore : : 2023.,
面頁冊數:
xxiii, 185 p. :ill. (some col.), digital ;24 cm.
內容註:
Cooking history and development of kitchen appliances -- Kitchen ventilation requirements -- Pollutions of cooking oil fume and health risks -- Thermal comfort in kitchen -- Basis to calculate exhaust airflow rate -- Design of kitchen ventilation -- High performance kitchen ventilation -- Stack effects of kitchen exhaust shaft in high-rise building -- Case study and design of kitchen ventilation.
Contained By:
Springer Nature eBook
標題:
Ventilation - Technological innovations. -
電子資源:
https://doi.org/10.1007/978-981-19-9259-9
ISBN:
9789811992599
Attachment ventilation theory
Li, Angui.
Attachment ventilation theory
[electronic resource] /by Angui Li. - Singapore :Springer Nature Singapore :2023. - xxiii, 185 p. :ill. (some col.), digital ;24 cm.
Cooking history and development of kitchen appliances -- Kitchen ventilation requirements -- Pollutions of cooking oil fume and health risks -- Thermal comfort in kitchen -- Basis to calculate exhaust airflow rate -- Design of kitchen ventilation -- High performance kitchen ventilation -- Stack effects of kitchen exhaust shaft in high-rise building -- Case study and design of kitchen ventilation.
Open access.
This open access book systematically summarizes the current research progress of attachment ventilation, covering vertical wall attachment, column attachment, and adaptive attachment ventilation. Attachment ventilation is a high-performance ventilation mode that was first proposed by the author, Prof. Angui Li 20 years ago. Now it has been widely used in office spaces, subway stations, high-speed railway stations, international airport terminals, and other large spaces. This book introduces attachment ventilation in detail to eliminate the cooling/heating load of the occupied zone and provide an expected environment for the air-conditioned zone. Attachment ventilation combines the advantages of traditional mixed ventilation and displacement ventilation. This book consists of six chapters, covering a series of airflow patterns, mechanisms, parameter correlations, and attachment ventilation design methods. It is helpful for HVAC engineers to design attachment ventilation effectively.
ISBN: 9789811992599
Standard No.: 10.1007/978-981-19-9259-9doiSubjects--Topical Terms:
3631757
Ventilation
--Technological innovations.
LC Class. No.: TH7678
Dewey Class. No.: 697.92
Attachment ventilation theory
LDR
:02369nmm a2200337 a 4500
001
2317557
003
DE-He213
005
20230502081823.0
006
m d
007
cr nn 008maaau
008
230902s2023 si s 0 eng d
020
$a
9789811992599
$q
(electronic bk.)
020
$a
9789811992582
$q
(paper)
024
7
$a
10.1007/978-981-19-9259-9
$2
doi
035
$a
978-981-19-9259-9
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
TH7678
072
7
$a
TNKH
$2
bicssc
072
7
$a
TEC009020
$2
bisacsh
072
7
$a
TNKE
$2
thema
082
0 4
$a
697.92
$2
23
090
$a
TH7678
$b
.L693 2023
100
1
$a
Li, Angui.
$3
2055148
245
1 0
$a
Attachment ventilation theory
$h
[electronic resource] /
$c
by Angui Li.
260
$a
Singapore :
$b
Springer Nature Singapore :
$b
Imprint: Springer,
$c
2023.
300
$a
xxiii, 185 p. :
$b
ill. (some col.), digital ;
$c
24 cm.
505
0
$a
Cooking history and development of kitchen appliances -- Kitchen ventilation requirements -- Pollutions of cooking oil fume and health risks -- Thermal comfort in kitchen -- Basis to calculate exhaust airflow rate -- Design of kitchen ventilation -- High performance kitchen ventilation -- Stack effects of kitchen exhaust shaft in high-rise building -- Case study and design of kitchen ventilation.
506
$a
Open access.
520
$a
This open access book systematically summarizes the current research progress of attachment ventilation, covering vertical wall attachment, column attachment, and adaptive attachment ventilation. Attachment ventilation is a high-performance ventilation mode that was first proposed by the author, Prof. Angui Li 20 years ago. Now it has been widely used in office spaces, subway stations, high-speed railway stations, international airport terminals, and other large spaces. This book introduces attachment ventilation in detail to eliminate the cooling/heating load of the occupied zone and provide an expected environment for the air-conditioned zone. Attachment ventilation combines the advantages of traditional mixed ventilation and displacement ventilation. This book consists of six chapters, covering a series of airflow patterns, mechanisms, parameter correlations, and attachment ventilation design methods. It is helpful for HVAC engineers to design attachment ventilation effectively.
650
0
$a
Ventilation
$x
Technological innovations.
$3
3631757
650
1 4
$a
Building Physics, HVAC.
$3
2055153
650
2 4
$a
Engineering Fluid Dynamics.
$3
891349
650
2 4
$a
Building Information Modeling.
$3
3598693
650
2 4
$a
Computer Modelling.
$3
3538541
710
2
$a
SpringerLink (Online service)
$3
836513
773
0
$t
Springer Nature eBook
856
4 0
$u
https://doi.org/10.1007/978-981-19-9259-9
950
$a
Engineering (SpringerNature-11647)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9453807
電子資源
11.線上閱覽_V
電子書
EB TH7678
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入