語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Evaluation of the computer fire mode...
~
Society for Fire Protection Engineers.
FindBook
Google Book
Amazon
博客來
Evaluation of the computer fire model DETACT-QS
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Evaluation of the computer fire model DETACT-QS/ Society for Fire Protection Engineers.
出版者:
Cham :Springer International Publishing : : 2022.,
面頁冊數:
xxvi, 157 p. :ill., digital ;24 cm.
內容註:
Introduction -- Model Description -- Scenarios for Which Evaluation Is Sought -- Theoretical Basis for the Model -- Mathematical and Numerical Robustness -- Model Sensitivity -- Model Inputs0 -- Model Evaluation -- Summary of Analysis0 -- Limitations/User Guidelines -- Appendix A -- Appendix B.
Contained By:
Springer Nature eBook
標題:
Fires - Computer simulation. -
電子資源:
https://doi.org/10.1007/978-3-030-82295-8
ISBN:
9783030822958
Evaluation of the computer fire model DETACT-QS
Evaluation of the computer fire model DETACT-QS
[electronic resource] /Society for Fire Protection Engineers. - Cham :Springer International Publishing :2022. - xxvi, 157 p. :ill., digital ;24 cm. - The society of fire protection engineers series,2731-3646. - Society of fire protection engineers series..
Introduction -- Model Description -- Scenarios for Which Evaluation Is Sought -- Theoretical Basis for the Model -- Mathematical and Numerical Robustness -- Model Sensitivity -- Model Inputs0 -- Model Evaluation -- Summary of Analysis0 -- Limitations/User Guidelines -- Appendix A -- Appendix B.
This engineering practice Guide, based on the DETACT-QS program, describes a model for predicting the response time of ceiling-mounted heat detectors/sprinklers and smoke detectors, installed under large unobstructed ceilings, for fires with user-defined, time-dependent heat release rate curves. The Guide provides information on the technical features, theoretical basis, assumptions, limitations, and sensitivities as well as guidance on the use of DETACT-QS. Evaluation is based on comparing predictions from DETACT-QS with results from full-scale fire experiments conducted in compartments with ceiling heights ranging from 2.44 m (8 ft) to 12.2 m (40 ft) and peak fire heat release rates ranging from 150 kW to 3.8 MW. Use of this model with building geometries or fire characteristics other than those used in this evaluation may require further evaluation or testing.
ISBN: 9783030822958
Standard No.: 10.1007/978-3-030-82295-8doiSubjects--Topical Terms:
3592623
Fires
--Computer simulation.
LC Class. No.: TH9446.3 / .E83 2022
Dewey Class. No.: 628.92
Evaluation of the computer fire model DETACT-QS
LDR
:02231nmm a2200337 a 4500
001
2297244
003
DE-He213
005
20211221185948.0
006
m d
007
cr nn 008maaau
008
230324s2022 sz s 0 eng d
020
$a
9783030822958
$q
(electronic bk.)
020
$a
9783030822941
$q
(paper)
024
7
$a
10.1007/978-3-030-82295-8
$2
doi
035
$a
978-3-030-82295-8
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
TH9446.3
$b
.E83 2022
072
7
$a
TNKF
$2
bicssc
072
7
$a
TEC045000
$2
bisacsh
072
7
$a
TNKF
$2
thema
082
0 4
$a
628.92
$2
23
090
$a
TH9446.3
$b
.E92 2022
245
0 0
$a
Evaluation of the computer fire model DETACT-QS
$h
[electronic resource] /
$c
Society for Fire Protection Engineers.
260
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2022.
300
$a
xxvi, 157 p. :
$b
ill., digital ;
$c
24 cm.
490
1
$a
The society of fire protection engineers series,
$x
2731-3646
505
0
$a
Introduction -- Model Description -- Scenarios for Which Evaluation Is Sought -- Theoretical Basis for the Model -- Mathematical and Numerical Robustness -- Model Sensitivity -- Model Inputs0 -- Model Evaluation -- Summary of Analysis0 -- Limitations/User Guidelines -- Appendix A -- Appendix B.
520
$a
This engineering practice Guide, based on the DETACT-QS program, describes a model for predicting the response time of ceiling-mounted heat detectors/sprinklers and smoke detectors, installed under large unobstructed ceilings, for fires with user-defined, time-dependent heat release rate curves. The Guide provides information on the technical features, theoretical basis, assumptions, limitations, and sensitivities as well as guidance on the use of DETACT-QS. Evaluation is based on comparing predictions from DETACT-QS with results from full-scale fire experiments conducted in compartments with ceiling heights ranging from 2.44 m (8 ft) to 12.2 m (40 ft) and peak fire heat release rates ranging from 150 kW to 3.8 MW. Use of this model with building geometries or fire characteristics other than those used in this evaluation may require further evaluation or testing.
650
0
$a
Fires
$x
Computer simulation.
$3
3592623
650
0
$a
Fire prevention
$x
Data processing.
$3
3592624
650
1 4
$a
Fire Science, Hazard Control, Building Safety.
$3
3219554
650
2 4
$a
Computer Applications.
$3
891249
710
2
$a
Society for Fire Protection Engineers.
$3
3592622
710
2
$a
SpringerLink (Online service)
$3
836513
773
0
$t
Springer Nature eBook
830
0
$a
Society of fire protection engineers series.
$3
3522071
856
4 0
$u
https://doi.org/10.1007/978-3-030-82295-8
950
$a
Engineering (SpringerNature-11647)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9439136
電子資源
11.線上閱覽_V
電子書
EB TH9446.3 .E83 2022
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入