Freeform Optical Surface Form Metrology with Serial Data Acquisition.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Freeform Optical Surface Form Metrology with Serial Data Acquisition./
作者:
Noste, Todd.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2021,
面頁冊數:
362 p.
附註:
Source: Dissertations Abstracts International, Volume: 82-07, Section: B.
Contained By:
Dissertations Abstracts International82-07B.
標題:
Mechanical engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28263872
ISBN:
9798557044141
Freeform Optical Surface Form Metrology with Serial Data Acquisition.
Noste, Todd.
Freeform Optical Surface Form Metrology with Serial Data Acquisition.
- Ann Arbor : ProQuest Dissertations & Theses, 2021 - 362 p.
Source: Dissertations Abstracts International, Volume: 82-07, Section: B.
Thesis (Ph.D.)--The University of North Carolina at Charlotte, 2021.
This item must not be sold to any third party vendors.
Freeform optics, or optics with no axis of rotational invariance, provide optical designers more degrees of freedom, flexibility, and opportunity for innovation increasing optical performance and system integration while decreasing the form factor. Advancements in optical fabrication have enabled freeform surface manufacture with greater precision. Metrology instruments and techniques are needed to verify the performance of freeform optical surfaces and systems to keep up with design and manufacture. Freeform optics often have high slopes, no axis of symmetry, and a large departure from spherical, making traditional metrology techniques inadequate. This research was conducted to enable form measurements of freeform mirrors in the 250 mm class for a next generation three mirror anastigmatic (TMA) telescope complete with a statement of the measurement uncertainty to fill the gap in metrology of freeform optics. A flexible metrology instrument that could measure relatively large optics with customizable probe paths and sampling strategies was needed while maintaining the required uncertainty.Measurements were made using a Moore Nanotech 100UMM 4-axis coordinate measurement machine (CMM) with a probe path that allows for estimation of the thermal error and the possibility of compensation. A mathematical model was developed for the 100UMM using transformation matrices populated with the part and probe position vectors, probe displacement, machine carriage positions, geometric machine errors and probing errors. The model is used in geometric error compensation and a Monte Carlo simulation used for evaluating the task specific uncertainty. The geometric machine errors were measured for error compensation and the uncertainty in those measurements was used in the Monte Carlo simulation for task specific uncertainty evaluation of parts measured on the 100UMM. The mathematical model is also used to solve for the machine carriage positions to automate writing the machine language (g-code) for programming the probe path. A chromatic confocal optical probe was used to measure the reflective freeform optics. The Precitec chromatic confocal probe used is non-contact, has a large angle of acceptance, a 4.5 mm working distance and a 300 µm range. Initially, a point by point measurement strategy was used. To reduce overall measurement time for point to point measurements, the probe path was chosen using the traveling salesman approach. The traveling salesman problem (TSP) uses an algorithm to reduce the total distance traveled during the measurement in 3D space.Thermal characteristics of the 100UMM were evaluated using drift tests and temperature measurements. Drift tests are used to evaluate the amount of correlation between temperature and probe displacement. An environmentally controlled enclosure was installed around the 100UMM to stabilize the temperature of the ambient air, the high-pressure air going to the air bearings and the hydraulic oil for the hydrostatic bearings. The enclosure is designed to hold the metrology loop at 20 °C +/- 0.1 °C.Despite housing the 100UMM in an environmentally controlled enclosure, thermal error estimation and correction was necessary. Through probe path optimization and planning, thermal drift was estimated and corrected while the measurement time was reduced further decreasing the thermal drift. Limiting carriage movement while recording measurement data reduces the amount of thermal drift due to moving heat sources from the hydrostatic bearings and the drive motors on the carriages.The measurement time was reduced by a considerable amount by changing from a point by point measurement mode to a scanning measurement mode. By reducing measurement time, time varying errors including thermal error contributions are also reduced. The scanning mode, where the probe is moved over the surface of the part while recording the probe displacement, requires reading the machine scales directly and syncing the data acquisition of the probe displacement and machine carriage positions. The inability to sync the machine carriage positions and probe displacement at precisely the same time results in data age uncertainty. The data age uncertainty is reduced by limiting the carriage velocity, and number of carriages moving simultaneously.According to the guide to the expression of uncertainty in measurement (GUM) a measurement is not complete without a statement of uncertainty. A Monte Carlo simulation is used to evaluate the task specific uncertainty of parts measured on the CMM. The Monte Carlo simulation utilizes the mathematical machine model populated with the uncertainty in the machine and probe error measurements used for error compensation to evaluate the uncertainty in the best estimate of the surface being measured and specified measurands.To validate the metrology instrument and process, two half scale mirrors of third (tertiary) mirror in the AFRL TMA telescope was measured many times and in multiple setups for repeatability and reproducibility. The measurement result and statement of uncertainty were compared with the prescription and tolerances for acceptance. A spherical mirror made of glass was measured on a Fizeau interferometer and the 100UMM for a comparison of the measurement results after error compensation.
ISBN: 9798557044141Subjects--Topical Terms:
649730
Mechanical engineering.
Subjects--Index Terms:
Coordinate measuring machine
Freeform Optical Surface Form Metrology with Serial Data Acquisition.
LDR
:06546nmm a2200373 4500
001
2285133
005
20211129123947.5
008
220723s2021 ||||||||||||||||| ||eng d
020
$a
9798557044141
035
$a
(MiAaPQ)AAI28263872
035
$a
AAI28263872
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Noste, Todd.
$3
3564420
245
1 0
$a
Freeform Optical Surface Form Metrology with Serial Data Acquisition.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2021
300
$a
362 p.
500
$a
Source: Dissertations Abstracts International, Volume: 82-07, Section: B.
500
$a
Advisor: Evans, Christopher J.
502
$a
Thesis (Ph.D.)--The University of North Carolina at Charlotte, 2021.
506
$a
This item must not be sold to any third party vendors.
520
$a
Freeform optics, or optics with no axis of rotational invariance, provide optical designers more degrees of freedom, flexibility, and opportunity for innovation increasing optical performance and system integration while decreasing the form factor. Advancements in optical fabrication have enabled freeform surface manufacture with greater precision. Metrology instruments and techniques are needed to verify the performance of freeform optical surfaces and systems to keep up with design and manufacture. Freeform optics often have high slopes, no axis of symmetry, and a large departure from spherical, making traditional metrology techniques inadequate. This research was conducted to enable form measurements of freeform mirrors in the 250 mm class for a next generation three mirror anastigmatic (TMA) telescope complete with a statement of the measurement uncertainty to fill the gap in metrology of freeform optics. A flexible metrology instrument that could measure relatively large optics with customizable probe paths and sampling strategies was needed while maintaining the required uncertainty.Measurements were made using a Moore Nanotech 100UMM 4-axis coordinate measurement machine (CMM) with a probe path that allows for estimation of the thermal error and the possibility of compensation. A mathematical model was developed for the 100UMM using transformation matrices populated with the part and probe position vectors, probe displacement, machine carriage positions, geometric machine errors and probing errors. The model is used in geometric error compensation and a Monte Carlo simulation used for evaluating the task specific uncertainty. The geometric machine errors were measured for error compensation and the uncertainty in those measurements was used in the Monte Carlo simulation for task specific uncertainty evaluation of parts measured on the 100UMM. The mathematical model is also used to solve for the machine carriage positions to automate writing the machine language (g-code) for programming the probe path. A chromatic confocal optical probe was used to measure the reflective freeform optics. The Precitec chromatic confocal probe used is non-contact, has a large angle of acceptance, a 4.5 mm working distance and a 300 µm range. Initially, a point by point measurement strategy was used. To reduce overall measurement time for point to point measurements, the probe path was chosen using the traveling salesman approach. The traveling salesman problem (TSP) uses an algorithm to reduce the total distance traveled during the measurement in 3D space.Thermal characteristics of the 100UMM were evaluated using drift tests and temperature measurements. Drift tests are used to evaluate the amount of correlation between temperature and probe displacement. An environmentally controlled enclosure was installed around the 100UMM to stabilize the temperature of the ambient air, the high-pressure air going to the air bearings and the hydraulic oil for the hydrostatic bearings. The enclosure is designed to hold the metrology loop at 20 °C +/- 0.1 °C.Despite housing the 100UMM in an environmentally controlled enclosure, thermal error estimation and correction was necessary. Through probe path optimization and planning, thermal drift was estimated and corrected while the measurement time was reduced further decreasing the thermal drift. Limiting carriage movement while recording measurement data reduces the amount of thermal drift due to moving heat sources from the hydrostatic bearings and the drive motors on the carriages.The measurement time was reduced by a considerable amount by changing from a point by point measurement mode to a scanning measurement mode. By reducing measurement time, time varying errors including thermal error contributions are also reduced. The scanning mode, where the probe is moved over the surface of the part while recording the probe displacement, requires reading the machine scales directly and syncing the data acquisition of the probe displacement and machine carriage positions. The inability to sync the machine carriage positions and probe displacement at precisely the same time results in data age uncertainty. The data age uncertainty is reduced by limiting the carriage velocity, and number of carriages moving simultaneously.According to the guide to the expression of uncertainty in measurement (GUM) a measurement is not complete without a statement of uncertainty. A Monte Carlo simulation is used to evaluate the task specific uncertainty of parts measured on the CMM. The Monte Carlo simulation utilizes the mathematical machine model populated with the uncertainty in the machine and probe error measurements used for error compensation to evaluate the uncertainty in the best estimate of the surface being measured and specified measurands.To validate the metrology instrument and process, two half scale mirrors of third (tertiary) mirror in the AFRL TMA telescope was measured many times and in multiple setups for repeatability and reproducibility. The measurement result and statement of uncertainty were compared with the prescription and tolerances for acceptance. A spherical mirror made of glass was measured on a Fizeau interferometer and the 100UMM for a comparison of the measurement results after error compensation.
590
$a
School code: 0694.
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Optics.
$3
517925
653
$a
Coordinate measuring machine
653
$a
Freeform optics
653
$a
Machine tool metrology
653
$a
Mathematical model
653
$a
Metrology
653
$a
Monte Carlo simulation
690
$a
0548
690
$a
0752
710
2
$a
The University of North Carolina at Charlotte.
$b
Mechanical Engineering.
$3
1286885
773
0
$t
Dissertations Abstracts International
$g
82-07B.
790
$a
0694
791
$a
Ph.D.
792
$a
2021
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28263872
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9436866
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入