語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Assessing the Impact of Industrial W...
~
Sopian, Nini Fatahna Muhamad.
FindBook
Google Book
Amazon
博客來
Assessing the Impact of Industrial Wastewater Reuse as a Demand-Side Management Strategy for Potable Water Deficit in Selangor, Malaysia.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Assessing the Impact of Industrial Wastewater Reuse as a Demand-Side Management Strategy for Potable Water Deficit in Selangor, Malaysia./
作者:
Sopian, Nini Fatahna Muhamad.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2019,
面頁冊數:
263 p.
附註:
Source: Dissertations Abstracts International, Volume: 81-09, Section: A.
Contained By:
Dissertations Abstracts International81-09A.
標題:
Environmental engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=27801698
ISBN:
9781392662663
Assessing the Impact of Industrial Wastewater Reuse as a Demand-Side Management Strategy for Potable Water Deficit in Selangor, Malaysia.
Sopian, Nini Fatahna Muhamad.
Assessing the Impact of Industrial Wastewater Reuse as a Demand-Side Management Strategy for Potable Water Deficit in Selangor, Malaysia.
- Ann Arbor : ProQuest Dissertations & Theses, 2019 - 263 p.
Source: Dissertations Abstracts International, Volume: 81-09, Section: A.
Thesis (Ph.D.)--University of Surrey (United Kingdom), 2019.
This item must not be sold to any third party vendors.
Policy makers are now re-aligning their thinking towards demand-side management (DSM), where for the industrial sector specifically, strategies have been emphasising water consumption reduction through conservation, increased efficiency, and wastewater recycling. Although DSM-based strategies have been seen as a viable option to delay the need for large capital investment and to avoid irreversible environmental impact, their implementation at a large scale have been largely unknown as is implementation has generally been reported at a small-scale. As such, this research attempts to assess the effectiveness of implementation of decentralised wastewater reuse facilities in industrial parks as a DSM-based strategy targeted at the manufacturing sector. The research first assessed the vulnerability of three reservoirs in Selangor-namely Semenyih, Klang Gates, and Langat dam-against water deficiency events using a modelling approach to analyse their: i) reliability, via the use of an inflow-demand reliability index, and ii) resilience, through a water supply resilience index. Total potential potable water savings were then estimated for all industrial parks in the area served by each reservoir and subsequent potable water treatment plant. The impact of the potential water savings through reuse of wastewater in industrial parks within an overall water supply system was then evaluated. The feasibility of this DSM-based strategy was assessed in terms of its technical, economics, and environmental impact. Four treatment trains corresponding to the two cases of i) potable and ii) non-potable reuse were assessed in terms of their removal efficiencies necessary to comply with the current potable and non-potable water quality standards. The financial cost of each treatment train was determined for both capital and operational costs, while the environmental assessment was assessed using a Life Cycle Assessment (LCA) approach based on several environmental impact categories. Findings for the three dams indicated varying level of vulnerability, with Klang Gates dam being the most vulnerable, while Semenyih the least. For Klang Gates and Langat dams, the resultant IDR and WSR indexes achieved similar conclusions; both indices resulted in almost constant negative values for both dams, suggesting that an effective DSM-based strategy could possibly delay the need for implementation of an SSM strategy. For Semenyih dam, it was observed that the system is approaching system vulnerability, where lower IDR and WSR values were observed in the later years as compared to historical scenarios. Here, it can be hypothesised that a well-planned DSM-based strategy might eliminate the need for a SSM strategy. It was found that there was minimal number of industrial parks within the Klang Gates water supply area, further reducing the feasibility of wastewater reuse to reduce the vulnerability of this WSS. Conversely, it was estimated that, for Langat and Semenyih WSS, approximately 308,903 and 430,281 m3/month of water consumed by the premises within the identified IPs. This translates to approximately 266,430 and 374,009 m3/month of water savings if 90% of the total demand was discarded as effluent, and treated at 95% recovery rate. The savings calculated for this reuse option could contribute to a savings of 5.5% (8.8 MLD) and 12.2% (12.47 MLD) for the Langat and Semenyih dam respectively. These accumulated savings had a different impact on each dam's vulnerability. For the Langat dam, recalculation of the IDR and WSR values with the savings indicated little change to the system's overall vulnerability. In contrast, recalculations for the Semenyih dam resulted in positive changes for the WSR specifically, indicating reduced vulnerability of the system. The feasibility of four treatment trains corresponding to both reuse options for their technical, financial, and environmental dimensions were considered. The general findings in all three dimensions reinforced the option of non-potable reuse, specifically the NP-1 treatment train, which resulted in the lowest cost while providing the highest technical capability to remove contaminants from the industrial wastewater to meet both non-potable and potable water reuse standards. Additionally, from the environmental perspective, the resultant water for reuse had a lower human toxicity impact without an additional blending requirement, though this produced a higher terrestrial eco-toxicity impact due to the contaminants removal to landfill. On the other hand, it was also illustrated via this research that the additional financial resources, institutional reconfiguration of existing water service industry, as well as current awareness of the industrial players itself will limit the effective implementation of the identified strategy. As such, it was concluded that, although the use of industrial wastewater for manufacturing sector is technical, financial, and environmental feasible, its deployment however, is improbable against the current organizational structure and current awareness of the users.
ISBN: 9781392662663Subjects--Topical Terms:
548583
Environmental engineering.
Subjects--Index Terms:
Industrial wastewater reuse
Assessing the Impact of Industrial Wastewater Reuse as a Demand-Side Management Strategy for Potable Water Deficit in Selangor, Malaysia.
LDR
:06414nmm a2200385 4500
001
2273094
005
20201105110340.5
008
220629s2019 ||||||||||||||||| ||eng d
020
$a
9781392662663
035
$a
(MiAaPQ)AAI27801698
035
$a
(MiAaPQ)Surrey850794
035
$a
AAI27801698
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Sopian, Nini Fatahna Muhamad.
$3
3550525
245
1 0
$a
Assessing the Impact of Industrial Wastewater Reuse as a Demand-Side Management Strategy for Potable Water Deficit in Selangor, Malaysia.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
263 p.
500
$a
Source: Dissertations Abstracts International, Volume: 81-09, Section: A.
500
$a
Advisor: Chenoweth, Jonathan;Murphy, Richard.
502
$a
Thesis (Ph.D.)--University of Surrey (United Kingdom), 2019.
506
$a
This item must not be sold to any third party vendors.
520
$a
Policy makers are now re-aligning their thinking towards demand-side management (DSM), where for the industrial sector specifically, strategies have been emphasising water consumption reduction through conservation, increased efficiency, and wastewater recycling. Although DSM-based strategies have been seen as a viable option to delay the need for large capital investment and to avoid irreversible environmental impact, their implementation at a large scale have been largely unknown as is implementation has generally been reported at a small-scale. As such, this research attempts to assess the effectiveness of implementation of decentralised wastewater reuse facilities in industrial parks as a DSM-based strategy targeted at the manufacturing sector. The research first assessed the vulnerability of three reservoirs in Selangor-namely Semenyih, Klang Gates, and Langat dam-against water deficiency events using a modelling approach to analyse their: i) reliability, via the use of an inflow-demand reliability index, and ii) resilience, through a water supply resilience index. Total potential potable water savings were then estimated for all industrial parks in the area served by each reservoir and subsequent potable water treatment plant. The impact of the potential water savings through reuse of wastewater in industrial parks within an overall water supply system was then evaluated. The feasibility of this DSM-based strategy was assessed in terms of its technical, economics, and environmental impact. Four treatment trains corresponding to the two cases of i) potable and ii) non-potable reuse were assessed in terms of their removal efficiencies necessary to comply with the current potable and non-potable water quality standards. The financial cost of each treatment train was determined for both capital and operational costs, while the environmental assessment was assessed using a Life Cycle Assessment (LCA) approach based on several environmental impact categories. Findings for the three dams indicated varying level of vulnerability, with Klang Gates dam being the most vulnerable, while Semenyih the least. For Klang Gates and Langat dams, the resultant IDR and WSR indexes achieved similar conclusions; both indices resulted in almost constant negative values for both dams, suggesting that an effective DSM-based strategy could possibly delay the need for implementation of an SSM strategy. For Semenyih dam, it was observed that the system is approaching system vulnerability, where lower IDR and WSR values were observed in the later years as compared to historical scenarios. Here, it can be hypothesised that a well-planned DSM-based strategy might eliminate the need for a SSM strategy. It was found that there was minimal number of industrial parks within the Klang Gates water supply area, further reducing the feasibility of wastewater reuse to reduce the vulnerability of this WSS. Conversely, it was estimated that, for Langat and Semenyih WSS, approximately 308,903 and 430,281 m3/month of water consumed by the premises within the identified IPs. This translates to approximately 266,430 and 374,009 m3/month of water savings if 90% of the total demand was discarded as effluent, and treated at 95% recovery rate. The savings calculated for this reuse option could contribute to a savings of 5.5% (8.8 MLD) and 12.2% (12.47 MLD) for the Langat and Semenyih dam respectively. These accumulated savings had a different impact on each dam's vulnerability. For the Langat dam, recalculation of the IDR and WSR values with the savings indicated little change to the system's overall vulnerability. In contrast, recalculations for the Semenyih dam resulted in positive changes for the WSR specifically, indicating reduced vulnerability of the system. The feasibility of four treatment trains corresponding to both reuse options for their technical, financial, and environmental dimensions were considered. The general findings in all three dimensions reinforced the option of non-potable reuse, specifically the NP-1 treatment train, which resulted in the lowest cost while providing the highest technical capability to remove contaminants from the industrial wastewater to meet both non-potable and potable water reuse standards. Additionally, from the environmental perspective, the resultant water for reuse had a lower human toxicity impact without an additional blending requirement, though this produced a higher terrestrial eco-toxicity impact due to the contaminants removal to landfill. On the other hand, it was also illustrated via this research that the additional financial resources, institutional reconfiguration of existing water service industry, as well as current awareness of the industrial players itself will limit the effective implementation of the identified strategy. As such, it was concluded that, although the use of industrial wastewater for manufacturing sector is technical, financial, and environmental feasible, its deployment however, is improbable against the current organizational structure and current awareness of the users.
590
$a
School code: 0597.
650
4
$a
Environmental engineering.
$3
548583
650
4
$a
Southeast Asian studies.
$3
3344898
650
4
$a
Water resources management.
$3
794747
653
$a
Industrial wastewater reuse
653
$a
Demand-side management strategy
653
$a
Potable water deficit
653
$a
Selangor
653
$a
Malaysia
690
$a
0775
690
$a
0222
690
$a
0595
710
2
$a
University of Surrey (United Kingdom).
$3
3286108
773
0
$t
Dissertations Abstracts International
$g
81-09A.
790
$a
0597
791
$a
Ph.D.
792
$a
2019
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=27801698
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9425328
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入