語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Real-time Monitoring of Particulate ...
~
Waez, Mir Seliman.
FindBook
Google Book
Amazon
博客來
Real-time Monitoring of Particulate Matter Size, Concentration, and Complex Index of Refraction.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Real-time Monitoring of Particulate Matter Size, Concentration, and Complex Index of Refraction./
作者:
Waez, Mir Seliman.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2019,
面頁冊數:
122 p.
附註:
Source: Dissertations Abstracts International, Volume: 81-05, Section: B.
Contained By:
Dissertations Abstracts International81-05B.
標題:
Mechanical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=22617162
ISBN:
9781088396773
Real-time Monitoring of Particulate Matter Size, Concentration, and Complex Index of Refraction.
Waez, Mir Seliman.
Real-time Monitoring of Particulate Matter Size, Concentration, and Complex Index of Refraction.
- Ann Arbor : ProQuest Dissertations & Theses, 2019 - 122 p.
Source: Dissertations Abstracts International, Volume: 81-05, Section: B.
Thesis (Ph.D.)--Kansas State University, 2019.
This item is not available from ProQuest Dissertations & Theses.
This dissertation focuses on real-time monitoring of particulate matter concentration and sizing, and determining the complex index of refraction of single particles simultaneously. We investigated application of low-cost optical dust sensors GP2Y1010AU0F for monitoring of indoor air quality (IAQ) in buildings; developed a single-particle detector for large, non-absorbing spherical particles so the particles could be sized independently of the refractive index; and developed another sensor to determine the size and complex index of refraction of single particles simultaneously.We calibrated low-cost optical dust sensors GP2Y1010AU0F using an aerodynamic particle sizer (APS) as a reference instrument. Four sensors were connected in series with the APS and data were collected simultaneously on the downstream of a flow loop where the aerosol concentration was controlled. Sensors' performances were compared to each other as well as to the manufacturer's calibration data. Sensors were also exposed at two different positions in a controlled chamber to collect (1) indoor air data and (2) indoor air data with incense burning; results were compared to the calibration data. Initially, it was found that sensors' data were different from each other by ±15%. This percentage was decreased to ±5.9% by adjusting the potentiometer on each sensor. Since the sensors work with light scattering, it was found their outputs were affected by ambient light levels causing uncertainties in the measured values. Sensors' data for indoor air with incense burning were affected by airflow. When connected in series to the APS with 5 L/min airflow passing through them, their data agreed with the calibration data; however, they did not agree when exposed to still air i.e., without airflow.To determine the size of non-absorbing spherical particles independent of their refractive indices, we found the differential scattering cross-section to be only independent of the real refractive index at angles near 37 ± 5°. We built a device by modifying a Gaussian incident beam profile to a diamond-shaped beam so that the beam transit time of a particle passing through it could determine the true incident intensity for the scattering of the particle. By combining the modified Gaussian incident beam profile with detection of scattered light near 37 ± 5°, we demonstrated a refractive-index independent measurement of single spherical particles as they passed through the beam.In order to simultaneously determine the size and complex index of refraction of single particles, we developed a sensor that measures the scattered-light intensity of particles at three different scattering angles, i.e., 37 ± 5°, 80 ± 5°, and 115 ± 5°, in a diamond-shaped beam. The differential scattering cross-section is only independent of the real part of the refractive index at 37 ± 5°; however, in the case of absorbing particles, it depends on the imaginary part. At 115°, particles can be sized independently of the imaginary component; however, at 80°, it depends on both the real and the imaginary components. Although this dependence agrees at several angles, we have chosen 80° because the variation of the differential scattering cross-section at this angle is more consistent compared to other scattering angles.
ISBN: 9781088396773Subjects--Topical Terms:
649730
Mechanical engineering.
Subjects--Index Terms:
Complex index of refraction
Real-time Monitoring of Particulate Matter Size, Concentration, and Complex Index of Refraction.
LDR
:04659nmm a2200409 4500
001
2272750
005
20201105110213.5
008
220629s2019 ||||||||||||||||| ||eng d
020
$a
9781088396773
035
$a
(MiAaPQ)AAI22617162
035
$a
AAI22617162
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Waez, Mir Seliman.
$3
3550176
245
1 0
$a
Real-time Monitoring of Particulate Matter Size, Concentration, and Complex Index of Refraction.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
122 p.
500
$a
Source: Dissertations Abstracts International, Volume: 81-05, Section: B.
500
$a
Advisor: Eckels, Steven J.;Sorensen, Christopher M.
502
$a
Thesis (Ph.D.)--Kansas State University, 2019.
506
$a
This item is not available from ProQuest Dissertations & Theses.
506
$a
This item must not be sold to any third party vendors.
520
$a
This dissertation focuses on real-time monitoring of particulate matter concentration and sizing, and determining the complex index of refraction of single particles simultaneously. We investigated application of low-cost optical dust sensors GP2Y1010AU0F for monitoring of indoor air quality (IAQ) in buildings; developed a single-particle detector for large, non-absorbing spherical particles so the particles could be sized independently of the refractive index; and developed another sensor to determine the size and complex index of refraction of single particles simultaneously.We calibrated low-cost optical dust sensors GP2Y1010AU0F using an aerodynamic particle sizer (APS) as a reference instrument. Four sensors were connected in series with the APS and data were collected simultaneously on the downstream of a flow loop where the aerosol concentration was controlled. Sensors' performances were compared to each other as well as to the manufacturer's calibration data. Sensors were also exposed at two different positions in a controlled chamber to collect (1) indoor air data and (2) indoor air data with incense burning; results were compared to the calibration data. Initially, it was found that sensors' data were different from each other by ±15%. This percentage was decreased to ±5.9% by adjusting the potentiometer on each sensor. Since the sensors work with light scattering, it was found their outputs were affected by ambient light levels causing uncertainties in the measured values. Sensors' data for indoor air with incense burning were affected by airflow. When connected in series to the APS with 5 L/min airflow passing through them, their data agreed with the calibration data; however, they did not agree when exposed to still air i.e., without airflow.To determine the size of non-absorbing spherical particles independent of their refractive indices, we found the differential scattering cross-section to be only independent of the real refractive index at angles near 37 ± 5°. We built a device by modifying a Gaussian incident beam profile to a diamond-shaped beam so that the beam transit time of a particle passing through it could determine the true incident intensity for the scattering of the particle. By combining the modified Gaussian incident beam profile with detection of scattered light near 37 ± 5°, we demonstrated a refractive-index independent measurement of single spherical particles as they passed through the beam.In order to simultaneously determine the size and complex index of refraction of single particles, we developed a sensor that measures the scattered-light intensity of particles at three different scattering angles, i.e., 37 ± 5°, 80 ± 5°, and 115 ± 5°, in a diamond-shaped beam. The differential scattering cross-section is only independent of the real part of the refractive index at 37 ± 5°; however, in the case of absorbing particles, it depends on the imaginary part. At 115°, particles can be sized independently of the imaginary component; however, at 80°, it depends on both the real and the imaginary components. Although this dependence agrees at several angles, we have chosen 80° because the variation of the differential scattering cross-section at this angle is more consistent compared to other scattering angles.
590
$a
School code: 0100.
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Geophysics.
$3
535228
650
4
$a
Aeronomy.
$3
2102064
650
4
$a
Optics.
$3
517925
650
4
$a
Atmospheric sciences.
$3
3168354
653
$a
Complex index of refraction
653
$a
Light scattering
653
$a
Particle size
653
$a
Particulate matter
653
$a
Scattering angle
690
$a
0548
690
$a
0752
690
$a
0367
690
$a
0725
690
$a
0373
710
2
$a
Kansas State University.
$b
Department of Mechanical and Nuclear Engineering.
$3
3181448
773
0
$t
Dissertations Abstracts International
$g
81-05B.
790
$a
0100
791
$a
Ph.D.
792
$a
2019
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=22617162
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9424984
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入