語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Multimodal Optical Imaging of Seizur...
~
Ringuette, Dene.
FindBook
Google Book
Amazon
博客來
Multimodal Optical Imaging of Seizure with Flowmetry Stabilization.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Multimodal Optical Imaging of Seizure with Flowmetry Stabilization./
作者:
Ringuette, Dene.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2019,
面頁冊數:
201 p.
附註:
Source: Dissertations Abstracts International, Volume: 81-02, Section: B.
Contained By:
Dissertations Abstracts International81-02B.
標題:
Biomedical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13427243
ISBN:
9781085758659
Multimodal Optical Imaging of Seizure with Flowmetry Stabilization.
Ringuette, Dene.
Multimodal Optical Imaging of Seizure with Flowmetry Stabilization.
- Ann Arbor : ProQuest Dissertations & Theses, 2019 - 201 p.
Source: Dissertations Abstracts International, Volume: 81-02, Section: B.
Thesis (Ph.D.)--University of Toronto (Canada), 2019.
This item must not be sold to any third party vendors.
Two novel multimodal optical imaging systems, both providing concurrent full-field blood flow and oxygenation/volume mapping, were developed to investigate epilepsy-related disease models: 1) An epifluorescence microscope-integrated system, permitting simultaneous intracellular calcium imaging and electrographic recording of brain activity and 2) a miniaturized head-mounted system (collaborative work), permitting brain imaging of freely-behaving rats. The microscope-integrated system investigated microvascular dynamics during seizure, revealing large arteriole dilation associated with seizure onset. Furthermore, the electrographically correlated neurovascular seizure responses, intracellular calcium dynamics, and inter-seizure consistency were found to be modified after anti-seizure drug administration. The miniaturized system investigated an absence seizure model, revealing a previously under-characterized biphasic neurovascular response to motor arrest at seizure onset.Blood flow was measured using laser speckle contrast imaging (LSCI), permitting high spatiotemporal resolution flowmetry. While all the imaging modalities employed have a high dynamic range, LSCI-derived image sequences have rapidly varying high spatial frequency distortions. These distortions significantly reduce the reliability of misfocus correction and image registration approaches, which are required for brain-motion insensitive signal amplification. Novel speckle noise insensitive parameters were developed for sub-depth of field active LSCI misfocus correction and high precision LSCI image registration, permitting flowmetry stabilization. An adaptive cardiographic synchronization scheme enabled precise cardiac cycle-driven blood flow trace characterization and greater flowmetry stabilization than previously reported. The LSCI image registration approach exploited high precision vessel edge detection filters which are stable in the presence of a spatial sparsity enforcement scheme that preserves temporal flow dynamics. Consequently, these filters provide a data decompression mechanism that permits the measurement of arteriole diameter changes and blood flow dynamics at/below 1.0±0.5% and 0.10±0.05% data retention, respectively. Concurrent compression of oxygenation and calcium imaging data is feasible for most applications given their lower spatiotemporal contrast.Ongoing research is presented supporting the suitability of photoacoustic imaging for whole-brain myelin mapping, demyelination assessment, and hypoxia-ischemia tracking. Cardiographic synchronization permitted deep cerebral artery visualization with improved artery occlusion sensitivity.The several proof-of-principle innovations presented will enable expanded multimodal imaging studies of disease processes, progression and treatment effects in freely-behaving animals with improved flowmetry stability and data transmission efficiency.
ISBN: 9781085758659Subjects--Topical Terms:
535387
Biomedical engineering.
Multimodal Optical Imaging of Seizure with Flowmetry Stabilization.
LDR
:03960nmm a2200325 4500
001
2263337
005
20200316071948.5
008
220629s2019 ||||||||||||||||| ||eng d
020
$a
9781085758659
035
$a
(MiAaPQ)AAI13427243
035
$a
AAI13427243
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Ringuette, Dene.
$3
3540421
245
1 0
$a
Multimodal Optical Imaging of Seizure with Flowmetry Stabilization.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
201 p.
500
$a
Source: Dissertations Abstracts International, Volume: 81-02, Section: B.
500
$a
Advisor: Levi, Ofer;Carlen, Peter L.
502
$a
Thesis (Ph.D.)--University of Toronto (Canada), 2019.
506
$a
This item must not be sold to any third party vendors.
520
$a
Two novel multimodal optical imaging systems, both providing concurrent full-field blood flow and oxygenation/volume mapping, were developed to investigate epilepsy-related disease models: 1) An epifluorescence microscope-integrated system, permitting simultaneous intracellular calcium imaging and electrographic recording of brain activity and 2) a miniaturized head-mounted system (collaborative work), permitting brain imaging of freely-behaving rats. The microscope-integrated system investigated microvascular dynamics during seizure, revealing large arteriole dilation associated with seizure onset. Furthermore, the electrographically correlated neurovascular seizure responses, intracellular calcium dynamics, and inter-seizure consistency were found to be modified after anti-seizure drug administration. The miniaturized system investigated an absence seizure model, revealing a previously under-characterized biphasic neurovascular response to motor arrest at seizure onset.Blood flow was measured using laser speckle contrast imaging (LSCI), permitting high spatiotemporal resolution flowmetry. While all the imaging modalities employed have a high dynamic range, LSCI-derived image sequences have rapidly varying high spatial frequency distortions. These distortions significantly reduce the reliability of misfocus correction and image registration approaches, which are required for brain-motion insensitive signal amplification. Novel speckle noise insensitive parameters were developed for sub-depth of field active LSCI misfocus correction and high precision LSCI image registration, permitting flowmetry stabilization. An adaptive cardiographic synchronization scheme enabled precise cardiac cycle-driven blood flow trace characterization and greater flowmetry stabilization than previously reported. The LSCI image registration approach exploited high precision vessel edge detection filters which are stable in the presence of a spatial sparsity enforcement scheme that preserves temporal flow dynamics. Consequently, these filters provide a data decompression mechanism that permits the measurement of arteriole diameter changes and blood flow dynamics at/below 1.0±0.5% and 0.10±0.05% data retention, respectively. Concurrent compression of oxygenation and calcium imaging data is feasible for most applications given their lower spatiotemporal contrast.Ongoing research is presented supporting the suitability of photoacoustic imaging for whole-brain myelin mapping, demyelination assessment, and hypoxia-ischemia tracking. Cardiographic synchronization permitted deep cerebral artery visualization with improved artery occlusion sensitivity.The several proof-of-principle innovations presented will enable expanded multimodal imaging studies of disease processes, progression and treatment effects in freely-behaving animals with improved flowmetry stability and data transmission efficiency.
590
$a
School code: 0779.
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Optics.
$3
517925
650
4
$a
Physiology.
$3
518431
650
4
$a
Public health.
$3
534748
690
$a
0541
690
$a
0752
690
$a
0573
690
$a
0719
710
2
$a
University of Toronto (Canada).
$b
Biomedical Engineering.
$3
2101094
773
0
$t
Dissertations Abstracts International
$g
81-02B.
790
$a
0779
791
$a
Ph.D.
792
$a
2019
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13427243
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9415571
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入