Analysis of Metallic Shielding for Reduction of RF Induced Heating of Electrode During MRI for Active Implants.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Analysis of Metallic Shielding for Reduction of RF Induced Heating of Electrode During MRI for Active Implants./
作者:
Singhal, Krishna.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2018,
面頁冊數:
186 p.
附註:
Source: Dissertations Abstracts International, Volume: 80-03, Section: B.
Contained By:
Dissertations Abstracts International80-03B.
標題:
Electrical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10844963
ISBN:
9780438369085
Analysis of Metallic Shielding for Reduction of RF Induced Heating of Electrode During MRI for Active Implants.
Singhal, Krishna.
Analysis of Metallic Shielding for Reduction of RF Induced Heating of Electrode During MRI for Active Implants.
- Ann Arbor : ProQuest Dissertations & Theses, 2018 - 186 p.
Source: Dissertations Abstracts International, Volume: 80-03, Section: B.
Thesis (Ph.D.)--Purdue University, 2018.
This item must not be sold to any third party vendors.
The options available to patients with implantable devices are limited. It is because there are multiple interactions between the MRI environment and the implantable medical devices. The three main components of MRI systems- static magnet, RF coil, and a gradient coil- interact with the implantable medical devices. These interactions can cause force, torque, device vibrations and RF-induced heating. Among all these potential hazards is the heating caused by the RF electromagnetic field. The lead wires of the implants can act as antennas and pick up the electric field generated by the RF coil. This results in the induced current traveling along the length of the device that will dissipate as heat where it is coupled to tissue. The combination of critically sensitive tissues and high heat makes this interaction the most significant risk for patient safety. Hence, there arises a need to design effective techniques that can minimize RF heating induced during an MRI. The technique of shielding has been proven to reduce RF-induced heating. The focus of current research is to provide analysis of shielding technique for reduction of RF-induced heating of electrodes during MRI. Shielded leads have been developed as a method to reduce RF-heating responsible for temperature rise at the electrodes. The purpose of this work is to provide a quantitative understanding of how a conducting metallic shield over a lead will reduce RF heating at the electrode during MRI scans. A physical model and equations for reduction of RF heating by a shielded lead are presented. Temperature rises are calculated for different lengths of shielded and unshielded leads. Confirming measurements are made for a quarter-wavelength coaxial cable model of the lead. Measured temperature rise and transfer function depended on terminations conditions, with the shorted lead exhibiting the temperature rise sixteen times less than an open-ended lead. The information provided by this work is expected to facilitate the development of lead wires with reduced RF-induced heating. The availability of lead wires with reduced heating will allow expanded access to MRI by patients with implantable devices.
ISBN: 9780438369085Subjects--Topical Terms:
649834
Electrical engineering.
Analysis of Metallic Shielding for Reduction of RF Induced Heating of Electrode During MRI for Active Implants.
LDR
:03314nmm a2200337 4500
001
2210486
005
20191121124228.5
008
201008s2018 ||||||||||||||||| ||eng d
020
$a
9780438369085
035
$a
(MiAaPQ)AAI10844963
035
$a
(MiAaPQ)purdue:23225
035
$a
AAI10844963
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Singhal, Krishna.
$3
3437627
245
1 0
$a
Analysis of Metallic Shielding for Reduction of RF Induced Heating of Electrode During MRI for Active Implants.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2018
300
$a
186 p.
500
$a
Source: Dissertations Abstracts International, Volume: 80-03, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Nyenhuis, John A.
502
$a
Thesis (Ph.D.)--Purdue University, 2018.
506
$a
This item must not be sold to any third party vendors.
520
$a
The options available to patients with implantable devices are limited. It is because there are multiple interactions between the MRI environment and the implantable medical devices. The three main components of MRI systems- static magnet, RF coil, and a gradient coil- interact with the implantable medical devices. These interactions can cause force, torque, device vibrations and RF-induced heating. Among all these potential hazards is the heating caused by the RF electromagnetic field. The lead wires of the implants can act as antennas and pick up the electric field generated by the RF coil. This results in the induced current traveling along the length of the device that will dissipate as heat where it is coupled to tissue. The combination of critically sensitive tissues and high heat makes this interaction the most significant risk for patient safety. Hence, there arises a need to design effective techniques that can minimize RF heating induced during an MRI. The technique of shielding has been proven to reduce RF-induced heating. The focus of current research is to provide analysis of shielding technique for reduction of RF-induced heating of electrodes during MRI. Shielded leads have been developed as a method to reduce RF-heating responsible for temperature rise at the electrodes. The purpose of this work is to provide a quantitative understanding of how a conducting metallic shield over a lead will reduce RF heating at the electrode during MRI scans. A physical model and equations for reduction of RF heating by a shielded lead are presented. Temperature rises are calculated for different lengths of shielded and unshielded leads. Confirming measurements are made for a quarter-wavelength coaxial cable model of the lead. Measured temperature rise and transfer function depended on terminations conditions, with the shorted lead exhibiting the temperature rise sixteen times less than an open-ended lead. The information provided by this work is expected to facilitate the development of lead wires with reduced RF-induced heating. The availability of lead wires with reduced heating will allow expanded access to MRI by patients with implantable devices.
590
$a
School code: 0183.
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Medical imaging.
$3
3172799
650
4
$a
Electromagnetics.
$3
3173223
690
$a
0544
690
$a
0574
690
$a
0607
710
2
$a
Purdue University.
$b
Electrical and Computer Engineering.
$3
1018497
773
0
$t
Dissertations Abstracts International
$g
80-03B.
790
$a
0183
791
$a
Ph.D.
792
$a
2018
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10844963
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9387035
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入