語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Design of a Microstrip Antenna and P...
~
West, Jakob Ian Xiaohou.
FindBook
Google Book
Amazon
博客來
Design of a Microstrip Antenna and PCB for Use in an Electrocorticography Biomedical Implant.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Design of a Microstrip Antenna and PCB for Use in an Electrocorticography Biomedical Implant./
作者:
West, Jakob Ian Xiaohou.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2019,
面頁冊數:
97 p.
附註:
Source: Masters Abstracts International, Volume: 80-09.
Contained By:
Masters Abstracts International80-09.
標題:
Biomedical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13806844
ISBN:
9780438991804
Design of a Microstrip Antenna and PCB for Use in an Electrocorticography Biomedical Implant.
West, Jakob Ian Xiaohou.
Design of a Microstrip Antenna and PCB for Use in an Electrocorticography Biomedical Implant.
- Ann Arbor : ProQuest Dissertations & Theses, 2019 - 97 p.
Source: Masters Abstracts International, Volume: 80-09.
Thesis (M.S.)--The University of North Carolina at Charlotte, 2019.
This item must not be added to any third party search indexes.
An implantable system, that is part of a wireless body area network, is under development for a study monitoring of neural activity in rats with epilepsy. The study will continue over a nine month period to collect data for epilepsy research. This implantable system is part of a wireless body area network (WBAN) that consists of the implant, a data link, and a base station. The implant contains an insulation layer, an antenna, electronic components, and a power supply. A grid of electrodes implanted into the rat will serve to relay brain signals through the electronics to the antenna. A microstrip antenna is designed to operate in the unlicensed 2.4GHz ISM band to facilitate the wireless data link in the WBAN. Because the implanted system is surrounded by conductive biological tissue, it must be encapsulated in an insulating layer that shields the subject and the implant from each other. The dielectric properties of these tissues are modeled over time and frequency by a Cole-Cole model that is used in simulation software. The specific absorption rate (SAR) of these tissues is investigated, with respect to the input power of the antenna, to determine if the implant is safe to be used on a live subject. The communication system that captures the brain signals and digitizes them to be sent wirelessly over the data link for analysis at the base station is designed with off the shelf components.
ISBN: 9780438991804Subjects--Topical Terms:
535387
Biomedical engineering.
Design of a Microstrip Antenna and PCB for Use in an Electrocorticography Biomedical Implant.
LDR
:02587nmm a2200349 4500
001
2208156
005
20190929184225.5
008
201008s2019 ||||||||||||||||| ||eng d
020
$a
9780438991804
035
$a
(MiAaPQ)AAI13806844
035
$a
(MiAaPQ)uncc:11980
035
$a
AAI13806844
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
West, Jakob Ian Xiaohou.
$3
3435170
245
1 0
$a
Design of a Microstrip Antenna and PCB for Use in an Electrocorticography Biomedical Implant.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
97 p.
500
$a
Source: Masters Abstracts International, Volume: 80-09.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Adams, Ryan.
502
$a
Thesis (M.S.)--The University of North Carolina at Charlotte, 2019.
506
$a
This item must not be added to any third party search indexes.
506
$a
This item must not be sold to any third party vendors.
520
$a
An implantable system, that is part of a wireless body area network, is under development for a study monitoring of neural activity in rats with epilepsy. The study will continue over a nine month period to collect data for epilepsy research. This implantable system is part of a wireless body area network (WBAN) that consists of the implant, a data link, and a base station. The implant contains an insulation layer, an antenna, electronic components, and a power supply. A grid of electrodes implanted into the rat will serve to relay brain signals through the electronics to the antenna. A microstrip antenna is designed to operate in the unlicensed 2.4GHz ISM band to facilitate the wireless data link in the WBAN. Because the implanted system is surrounded by conductive biological tissue, it must be encapsulated in an insulating layer that shields the subject and the implant from each other. The dielectric properties of these tissues are modeled over time and frequency by a Cole-Cole model that is used in simulation software. The specific absorption rate (SAR) of these tissues is investigated, with respect to the input power of the antenna, to determine if the implant is safe to be used on a live subject. The communication system that captures the brain signals and digitizes them to be sent wirelessly over the data link for analysis at the base station is designed with off the shelf components.
590
$a
School code: 0694.
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Electromagnetics.
$3
3173223
690
$a
0541
690
$a
0544
690
$a
0607
710
2
$a
The University of North Carolina at Charlotte.
$b
Electrical Engineering.
$3
3170016
773
0
$t
Masters Abstracts International
$g
80-09.
790
$a
0694
791
$a
M.S.
792
$a
2019
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13806844
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9384705
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入