語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Venous Thromboembolism (VTE) Harm Me...
~
Marashi, Seyed Mani.
FindBook
Google Book
Amazon
博客來
Venous Thromboembolism (VTE) Harm Measurement and Risk Assessment in Real-Time Using Electronic Health Records(EHR).
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Venous Thromboembolism (VTE) Harm Measurement and Risk Assessment in Real-Time Using Electronic Health Records(EHR)./
作者:
Marashi, Seyed Mani.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2018,
面頁冊數:
127 p.
附註:
Source: Dissertations Abstracts International, Volume: 79-10, Section: B.
Contained By:
Dissertations Abstracts International79-10B.
標題:
Information Technology. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10681845
ISBN:
9780355826845
Venous Thromboembolism (VTE) Harm Measurement and Risk Assessment in Real-Time Using Electronic Health Records(EHR).
Marashi, Seyed Mani.
Venous Thromboembolism (VTE) Harm Measurement and Risk Assessment in Real-Time Using Electronic Health Records(EHR).
- Ann Arbor : ProQuest Dissertations & Theses, 2018 - 127 p.
Source: Dissertations Abstracts International, Volume: 79-10, Section: B.
Thesis (Ph.D.)--Wayne State University, 2018.
This item must not be sold to any third party vendors.
Venous Thromboembolism (VTE) is a deadly disease and is considered as one of the top reasons for avoidable hospital deaths in the United States and around the world. Patients who survive this disease often must face life-long complications such as Post-thrombotic syndrome (PTS), Chronic thromboembolic pulmonary hypertension (CTPH), etc. Therefore, it is important to monitor and reduce the number of VTE instances in hospitals. This study shows how Electronic Health Records (EHRs) can be utilized to achieve this goal. First, a new near real-time VTE harm measurement model was developed. Not only the developed model can deliver near real-time results, but also it can outperform the existing PSI12 measurement model that uses administrative data (sensitivity 84% vs. 38% and NPV 99% vs. 95%). In the next step, Padua VTE risk assessment model was developed inside the EHR to deliver real-time VTE risk assessment. Retrospective data analysis was also performed to show how another risk assessment model (IMPROVE) can be developed inside EHR. Analysis were completed to show and compare the effectiveness of each model. Finally, the results of utilizing the developed models are presented in terms of contributions to savings for the health system as well as the number of lives saved.
ISBN: 9780355826845Subjects--Topical Terms:
1030799
Information Technology.
Venous Thromboembolism (VTE) Harm Measurement and Risk Assessment in Real-Time Using Electronic Health Records(EHR).
LDR
:02428nmm a2200337 4500
001
2207537
005
20190920131247.5
008
201008s2018 ||||||||||||||||| ||eng d
020
$a
9780355826845
035
$a
(MiAaPQ)AAI10681845
035
$a
(MiAaPQ)wayne:13538
035
$a
AAI10681845
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Marashi, Seyed Mani.
$3
3434523
245
1 0
$a
Venous Thromboembolism (VTE) Harm Measurement and Risk Assessment in Real-Time Using Electronic Health Records(EHR).
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2018
300
$a
127 p.
500
$a
Source: Dissertations Abstracts International, Volume: 79-10, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Chelst, Kenneth R.
502
$a
Thesis (Ph.D.)--Wayne State University, 2018.
506
$a
This item must not be sold to any third party vendors.
520
$a
Venous Thromboembolism (VTE) is a deadly disease and is considered as one of the top reasons for avoidable hospital deaths in the United States and around the world. Patients who survive this disease often must face life-long complications such as Post-thrombotic syndrome (PTS), Chronic thromboembolic pulmonary hypertension (CTPH), etc. Therefore, it is important to monitor and reduce the number of VTE instances in hospitals. This study shows how Electronic Health Records (EHRs) can be utilized to achieve this goal. First, a new near real-time VTE harm measurement model was developed. Not only the developed model can deliver near real-time results, but also it can outperform the existing PSI12 measurement model that uses administrative data (sensitivity 84% vs. 38% and NPV 99% vs. 95%). In the next step, Padua VTE risk assessment model was developed inside the EHR to deliver real-time VTE risk assessment. Retrospective data analysis was also performed to show how another risk assessment model (IMPROVE) can be developed inside EHR. Analysis were completed to show and compare the effectiveness of each model. Finally, the results of utilizing the developed models are presented in terms of contributions to savings for the health system as well as the number of lives saved.
590
$a
School code: 0254.
650
4
$a
Information Technology.
$3
1030799
650
4
$a
Industrial engineering.
$3
526216
650
4
$a
Medicine.
$3
641104
690
$a
0489
690
$a
0546
690
$a
0564
710
2
$a
Wayne State University.
$b
Industrial Engineering.
$3
1023564
773
0
$t
Dissertations Abstracts International
$g
79-10B.
790
$a
0254
791
$a
Ph.D.
792
$a
2018
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10681845
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9384086
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入