Scan parameter optimization and a temperature controller for scanned focussed ultrasound hyperthermia: A theoretical and experimental study.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Scan parameter optimization and a temperature controller for scanned focussed ultrasound hyperthermia: A theoretical and experimental study./
作者:
Lin, Win-Li.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 1990,
面頁冊數:
223 p.
附註:
Source: Dissertations Abstracts International, Volume: 52-08, Section: B.
Contained By:
Dissertations Abstracts International52-08B.
標題:
Biomedical research. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9103043
Scan parameter optimization and a temperature controller for scanned focussed ultrasound hyperthermia: A theoretical and experimental study.
Lin, Win-Li.
Scan parameter optimization and a temperature controller for scanned focussed ultrasound hyperthermia: A theoretical and experimental study.
- Ann Arbor : ProQuest Dissertations & Theses, 1990 - 223 p.
Source: Dissertations Abstracts International, Volume: 52-08, Section: B.
Thesis (Ph.D.)--The University of Arizona, 1990.
This item must not be sold to any third party vendors.
Maintenance of the treatment temperatures at their target levels in the face of disturbances, a uniform temperature distribution within the treatment region, an acceptable temperature rise outside that volume, a fast temperature rise, and stability are desirable characteristics of an optimal hyperthermia treatment control system. Since scanned, focussed ultrasound systems (SFUS) have a great deal of flexibility it is necessary to use such a feedback system in shaping the power field during hyperthermia treatments. For best use of such a system many complicated, interacting decisions must be made to obtain an optimal hyperthermia treatment. This dissertation studies this optimization problem using a simulation program which searches for the optimal scan parameters, and presents a PID plus bang-bang feedback control system which gives a suitable power distribution to meet the above requirements for this hyperthermia system. Several objective functions were studied and compared based on temperature criteria. An extensive objective function study has been done in order to determine; the best formulation for that objection function, the characteristics of that objective function near the optimal operating point, the effects of the scan parameters on that objective function, and the domain of acceptable initial guess points for obtaining a globally optimal solution. A further comprehensive study of the optimal temperature distributions attainable with single and multiple circular scans of a tumor was done. The results show that the optimal scan parameter configuration will allow this SFUS to produce a close to ideal treatment temperature distribution for a wide variety of clinically relevant conditions. To further study the variation of the temporal and spatial blood perfusion, a controller was used to obtain a more suitable power to meet the treatment needs. Both the simulation results and experimental animal results show that the controlled region can be rapidly heated to the target temperature with a small overshoot and maintained at that level in the face of disturbances. In vitro dog kidney model and in vivo dog thigh experiments show that the controller works well in practice, and verify that it can compensate for spatial and temporal blood perfusion variations. As shown in both these experiments and in simulations, the controller can be used for controlling a single temperature or multiple temperature points simultaneously, thus allowing relatively uniform temperature fields to be created.Subjects--Topical Terms:
3433833
Biomedical research.
Scan parameter optimization and a temperature controller for scanned focussed ultrasound hyperthermia: A theoretical and experimental study.
LDR
:03707nmm a2200325 4500
001
2207428
005
20190920101655.5
008
201008s1990 ||||||||||||||||| ||eng d
035
$a
(MiAaPQ)AAI9103043
035
$a
AAI9103043
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Lin, Win-Li.
$3
3434415
245
1 0
$a
Scan parameter optimization and a temperature controller for scanned focussed ultrasound hyperthermia: A theoretical and experimental study.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
1990
300
$a
223 p.
500
$a
Source: Dissertations Abstracts International, Volume: 52-08, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Roemer, Robert B.
502
$a
Thesis (Ph.D.)--The University of Arizona, 1990.
506
$a
This item must not be sold to any third party vendors.
506
$a
This item must not be added to any third party search indexes.
520
$a
Maintenance of the treatment temperatures at their target levels in the face of disturbances, a uniform temperature distribution within the treatment region, an acceptable temperature rise outside that volume, a fast temperature rise, and stability are desirable characteristics of an optimal hyperthermia treatment control system. Since scanned, focussed ultrasound systems (SFUS) have a great deal of flexibility it is necessary to use such a feedback system in shaping the power field during hyperthermia treatments. For best use of such a system many complicated, interacting decisions must be made to obtain an optimal hyperthermia treatment. This dissertation studies this optimization problem using a simulation program which searches for the optimal scan parameters, and presents a PID plus bang-bang feedback control system which gives a suitable power distribution to meet the above requirements for this hyperthermia system. Several objective functions were studied and compared based on temperature criteria. An extensive objective function study has been done in order to determine; the best formulation for that objection function, the characteristics of that objective function near the optimal operating point, the effects of the scan parameters on that objective function, and the domain of acceptable initial guess points for obtaining a globally optimal solution. A further comprehensive study of the optimal temperature distributions attainable with single and multiple circular scans of a tumor was done. The results show that the optimal scan parameter configuration will allow this SFUS to produce a close to ideal treatment temperature distribution for a wide variety of clinically relevant conditions. To further study the variation of the temporal and spatial blood perfusion, a controller was used to obtain a more suitable power to meet the treatment needs. Both the simulation results and experimental animal results show that the controlled region can be rapidly heated to the target temperature with a small overshoot and maintained at that level in the face of disturbances. In vitro dog kidney model and in vivo dog thigh experiments show that the controller works well in practice, and verify that it can compensate for spatial and temporal blood perfusion variations. As shown in both these experiments and in simulations, the controller can be used for controlling a single temperature or multiple temperature points simultaneously, thus allowing relatively uniform temperature fields to be created.
590
$a
School code: 0009.
650
4
$a
Biomedical research.
$3
3433833
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Radiology.
$3
894545
690
$a
0541
690
$a
0548
690
$a
0574
710
2
$a
The University of Arizona.
$3
1017508
773
0
$t
Dissertations Abstracts International
$g
52-08B.
790
$a
0009
791
$a
Ph.D.
792
$a
1990
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9103043
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9383977
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入