Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Deterministic Direct Aperture Optimi...
~
Nguyen, Dan Minh.
Linked to FindBook
Google Book
Amazon
博客來
Deterministic Direct Aperture Optimization Using Multiphase Piecewise Constant Segmentation.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Deterministic Direct Aperture Optimization Using Multiphase Piecewise Constant Segmentation./
Author:
Nguyen, Dan Minh.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2017,
Description:
190 p.
Notes:
Source: Dissertation Abstracts International, Volume: 78-09(E), Section: B.
Contained By:
Dissertation Abstracts International78-09B(E).
Subject:
Physics. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10271577
ISBN:
9781369737318
Deterministic Direct Aperture Optimization Using Multiphase Piecewise Constant Segmentation.
Nguyen, Dan Minh.
Deterministic Direct Aperture Optimization Using Multiphase Piecewise Constant Segmentation.
- Ann Arbor : ProQuest Dissertations & Theses, 2017 - 190 p.
Source: Dissertation Abstracts International, Volume: 78-09(E), Section: B.
Thesis (Ph.D.)--University of California, Los Angeles, 2017.
Purpose: Direct Aperture Optimization (DAO) attempts to incorporate machine constraints in the inverse optimization to eliminate the post-processing steps in fluence map optimization (FMO) that degrade plan quality. Current commercial DAO methods utilize a stochastic or greedy approach to search a small aperture solution space. In this study, we propose a novel deterministic direct aperture optimization that integrates the segmentation of fluence map in the optimization problem using the multiphase piecewise constant Mumford-Shah formulation.
ISBN: 9781369737318Subjects--Topical Terms:
516296
Physics.
Deterministic Direct Aperture Optimization Using Multiphase Piecewise Constant Segmentation.
LDR
:04421nmm a2200337 4500
001
2122683
005
20170922124937.5
008
180830s2017 ||||||||||||||||| ||eng d
020
$a
9781369737318
035
$a
(MiAaPQ)AAI10271577
035
$a
AAI10271577
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Nguyen, Dan Minh.
$3
3284649
245
1 0
$a
Deterministic Direct Aperture Optimization Using Multiphase Piecewise Constant Segmentation.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2017
300
$a
190 p.
500
$a
Source: Dissertation Abstracts International, Volume: 78-09(E), Section: B.
500
$a
Adviser: Ke Sheng.
502
$a
Thesis (Ph.D.)--University of California, Los Angeles, 2017.
520
$a
Purpose: Direct Aperture Optimization (DAO) attempts to incorporate machine constraints in the inverse optimization to eliminate the post-processing steps in fluence map optimization (FMO) that degrade plan quality. Current commercial DAO methods utilize a stochastic or greedy approach to search a small aperture solution space. In this study, we propose a novel deterministic direct aperture optimization that integrates the segmentation of fluence map in the optimization problem using the multiphase piecewise constant Mumford-Shah formulation.
520
$a
Methods: The deterministic DAO problem was formulated to include an L2-norm dose fidelity term to penalize differences between the projected dose and the prescribed dose, an anisotropic total variation term to promote piecewise continuity in the fluence maps, and the multiphase piecewise constant Mumford-Shah function to partition the fluence into pairwise discrete segments. A proximal-class, first-order primal-dual solver was implemented to solve the large scale optimization problem, and an alternating module strategy was implemented to update fluence and delivery segments. Three patients of varying complexity-one glioblastoma multiforme (GBM) patient, one lung (LNG) patient, and one bilateral head and neck (H&N) patient with 3 PTVs-were selected to test the new DAO method. For comparison, a popular and successful approach to DAO known as simulated annealing-a stochastic approach-was replicated. Each patient was planned using the Mumford-Shah based DAO (DAOMS) and the simulated annealing based DAO (DAOSA). PTV coverage, PTV homogeneity (D95/D5), and OAR sparing were assessed for each plan. In addition, high dose spillage, defined as the 50% isodose volume divided by the tumor volume, as well as conformity, defined as the van't Riet conformation number, were evaluated.
520
$a
Results: DAOMS achieved essentially the same OAR doses compared with the DAOSA plans for the GBM case. The average difference of OAR Dmax and Dmean between the two plans were within 0.05% of the plan prescription dose. The lung case showed slightly improved critical structure sparing using the DAOMS approach, where the average OAR Dmax and Dmean were reduced by 3.67% and 1.08%, respectively, of the prescription dose. The DAOMS plan substantially reduced OAR Dmax and Dmean by over 10% of the prescription dose for the H&N patient. The DAOMS plan substantially improved the H&N PTV coverage, increasing D99 by 6.98% of the prescription dose. For the GBM and LNG patients, the DAO MS and DAOSA plans had comparable high dose spillage but slightly worse conformity with the DAOMS approach. For the H&N plan, DAOMS was considerably superior in high dose spillage and conformity to the DAOSA. The deterministic approach can solve the DAO problem 9.5 to 40 times faster than the simulated annealing approach.
520
$a
Conclusions: A novel deterministic direct aperture optimization formulation was developed and evaluated. It combines fluence map optimization and the multiphase piecewise constant Mumford-Shah segmentation into a unified framework, and the resulting optimization problem can be solved efficiently. Compared to the widely and commercially used simulated annealing DAO approach, it showed comparable dosimetry behavior for simple plans, and substantially improved OAR sparing, PTV coverage, PTV homogeneity, high dose spillage, and conformity for the more complex H&N plan.
590
$a
School code: 0031.
650
4
$a
Physics.
$3
516296
650
4
$a
Medicine.
$3
641104
650
4
$a
Applied mathematics.
$3
2122814
690
$a
0605
690
$a
0564
690
$a
0364
710
2
$a
University of California, Los Angeles.
$b
Biomedical Physics 0119.
$3
3178859
773
0
$t
Dissertation Abstracts International
$g
78-09B(E).
790
$a
0031
791
$a
Ph.D.
792
$a
2017
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10271577
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9333297
電子資源
01.外借(書)_YB
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login