Computation and Measurement of Force and Tissue Damage for the Grasper-tissue Interface in Robot-assisted Minimal Invasive Surgery.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Computation and Measurement of Force and Tissue Damage for the Grasper-tissue Interface in Robot-assisted Minimal Invasive Surgery./
作者:
Cheng, Lei.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2015,
面頁冊數:
111 p.
附註:
Source: Dissertation Abstracts International, Volume: 76-12(E), Section: B.
Contained By:
Dissertation Abstracts International76-12B(E).
標題:
Mechanical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3718837
ISBN:
9781321988703
Computation and Measurement of Force and Tissue Damage for the Grasper-tissue Interface in Robot-assisted Minimal Invasive Surgery.
Cheng, Lei.
Computation and Measurement of Force and Tissue Damage for the Grasper-tissue Interface in Robot-assisted Minimal Invasive Surgery.
- Ann Arbor : ProQuest Dissertations & Theses, 2015 - 111 p.
Source: Dissertation Abstracts International, Volume: 76-12(E), Section: B.
Thesis (Ph.D.)--University of Washington, 2015.
Robot-assisted minimally invasive surgery (RMIS) has many benefits for patients. However, loss of haptic feedback in the technique is a major limitation to surgeons since extensive applied force due to the lack of haptic feedback may cause unrecognized tissue damage. Also a surgical simulator without touch sensation is less adequate to train medical students to handle tissue safely. Various previous studies have reported the quantified tissue damage resulting from mechanical compression such as due to a surgical instrument grasping tissue; however, most of them require in-vitro bench work analysis, which limits their application in clinical conditions. This work provides a nonlinear finite element (FE) analysis of the grasper-tissue interaction to predict the reaction force on grasper jaws and degree of damage inside tissue. It also investigates the effects of the boundary conditions and material properties of the FE model on the simulated von Mises stress value and tissue damage. Four FE models were analyzed: two-dimensional (2D) plane strain model, 2D plane stress model, full three-dimensional (3D) model, and 3D thin membrane model. Our study shows that for integrated von Mises stress and tissue damage computations, the 3D thin membrane model yielded results closest to the full 3D analysis and required only 0.2% of the compute time. Then the 3D thin membrane model was used further to extract the three descriptors (length, width and depth) of tissue deformation. Correlations between applied force from in vitro experiments and tissue models validate the ability to predict force from deformation. Finally, a wide range of grasper-tissue interfaces were evaluated regarding tissue damage magnitude and grasp quality. By comparing the results with previously published studies, we confirmed that the computational methodology is useful for researchers to develop and test various designs of graspers, reducing the need for time-consuming and expensive in vivo experiments. The results presented in this study can guide engineers to design surgical instruments to improve patient safety. Additionally it is useful for improving the surgical simulator performance by reflecting more realistic tissue material property and displaying tissue damage severity.
ISBN: 9781321988703Subjects--Topical Terms:
649730
Mechanical engineering.
Computation and Measurement of Force and Tissue Damage for the Grasper-tissue Interface in Robot-assisted Minimal Invasive Surgery.
LDR
:03264nmm a2200301 4500
001
2122021
005
20170830070107.5
008
180830s2015 ||||||||||||||||| ||eng d
020
$a
9781321988703
035
$a
(MiAaPQ)AAI3718837
035
$a
AAI3718837
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Cheng, Lei.
$3
2097825
245
1 0
$a
Computation and Measurement of Force and Tissue Damage for the Grasper-tissue Interface in Robot-assisted Minimal Invasive Surgery.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2015
300
$a
111 p.
500
$a
Source: Dissertation Abstracts International, Volume: 76-12(E), Section: B.
500
$a
Adviser: Blake Hannaford.
502
$a
Thesis (Ph.D.)--University of Washington, 2015.
520
$a
Robot-assisted minimally invasive surgery (RMIS) has many benefits for patients. However, loss of haptic feedback in the technique is a major limitation to surgeons since extensive applied force due to the lack of haptic feedback may cause unrecognized tissue damage. Also a surgical simulator without touch sensation is less adequate to train medical students to handle tissue safely. Various previous studies have reported the quantified tissue damage resulting from mechanical compression such as due to a surgical instrument grasping tissue; however, most of them require in-vitro bench work analysis, which limits their application in clinical conditions. This work provides a nonlinear finite element (FE) analysis of the grasper-tissue interaction to predict the reaction force on grasper jaws and degree of damage inside tissue. It also investigates the effects of the boundary conditions and material properties of the FE model on the simulated von Mises stress value and tissue damage. Four FE models were analyzed: two-dimensional (2D) plane strain model, 2D plane stress model, full three-dimensional (3D) model, and 3D thin membrane model. Our study shows that for integrated von Mises stress and tissue damage computations, the 3D thin membrane model yielded results closest to the full 3D analysis and required only 0.2% of the compute time. Then the 3D thin membrane model was used further to extract the three descriptors (length, width and depth) of tissue deformation. Correlations between applied force from in vitro experiments and tissue models validate the ability to predict force from deformation. Finally, a wide range of grasper-tissue interfaces were evaluated regarding tissue damage magnitude and grasp quality. By comparing the results with previously published studies, we confirmed that the computational methodology is useful for researchers to develop and test various designs of graspers, reducing the need for time-consuming and expensive in vivo experiments. The results presented in this study can guide engineers to design surgical instruments to improve patient safety. Additionally it is useful for improving the surgical simulator performance by reflecting more realistic tissue material property and displaying tissue damage severity.
590
$a
School code: 0250.
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Biomechanics.
$3
548685
690
$a
0548
690
$a
0541
690
$a
0648
710
2
$a
University of Washington.
$b
Mechanical Engineering.
$3
2092993
773
0
$t
Dissertation Abstracts International
$g
76-12B(E).
790
$a
0250
791
$a
Ph.D.
792
$a
2015
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3718837
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9332637
電子資源
01.外借(書)_YB
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入