語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Optimization of building envelope de...
~
Futrell, Benjamin Joseph.
FindBook
Google Book
Amazon
博客來
Optimization of building envelope design for daylighting and thermal performance.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Optimization of building envelope design for daylighting and thermal performance./
作者:
Futrell, Benjamin Joseph.
面頁冊數:
136 p.
附註:
Source: Dissertation Abstracts International, Volume: 77-05(E), Section: B.
Contained By:
Dissertation Abstracts International77-05B(E).
標題:
Engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3744312
ISBN:
9781339370637
Optimization of building envelope design for daylighting and thermal performance.
Futrell, Benjamin Joseph.
Optimization of building envelope design for daylighting and thermal performance.
- 136 p.
Source: Dissertation Abstracts International, Volume: 77-05(E), Section: B.
Thesis (Ph.D.)--The University of North Carolina at Charlotte, 2015.
Buildings account for 40% of US energy usage. A building's energy usage is largely determined by decisions made during its design. Such decisions relate to the form and orientation of the building, the materials used, and location of windows. A bi-objective building design optimization method was developed to minimize heating and cooling energy usage and maximize natural lighting (daylighting). Four optimization algorithms were integrated and evaluated based on efficiency and consistency of results. Thermal performance was evaluated by enclosure elements' (windows, floors, walls, and roofs) impact on heating and cooling energy. Lighting performance was evaluated by the frequency and magnitude at which natural light levels deviated from a desired range. To ensure the accuracy of results, a method of thermal model calibration was developed based on room temperature responses to various weather conditions. The model used for simulation-based optimization was first calibrated to measured values, of the building it represented, such that predicted and measured hourly room temperatures (°F) deviated by an RMSE of 0.82 on hot and cold days. Optimization results show that thermal and lighting performance can be significantly improved from an initial design and the associated Pareto front aids evaluation of trade-offs between the two.
ISBN: 9781339370637Subjects--Topical Terms:
586835
Engineering.
Optimization of building envelope design for daylighting and thermal performance.
LDR
:02291nmm a2200289 4500
001
2075977
005
20161028152035.5
008
170521s2015 ||||||||||||||||| ||eng d
020
$a
9781339370637
035
$a
(MiAaPQ)AAI3744312
035
$a
AAI3744312
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Futrell, Benjamin Joseph.
$3
3191400
245
1 0
$a
Optimization of building envelope design for daylighting and thermal performance.
300
$a
136 p.
500
$a
Source: Dissertation Abstracts International, Volume: 77-05(E), Section: B.
500
$a
Advisers: Ertunga C. Ozelkan; Dale Brentrup.
502
$a
Thesis (Ph.D.)--The University of North Carolina at Charlotte, 2015.
520
$a
Buildings account for 40% of US energy usage. A building's energy usage is largely determined by decisions made during its design. Such decisions relate to the form and orientation of the building, the materials used, and location of windows. A bi-objective building design optimization method was developed to minimize heating and cooling energy usage and maximize natural lighting (daylighting). Four optimization algorithms were integrated and evaluated based on efficiency and consistency of results. Thermal performance was evaluated by enclosure elements' (windows, floors, walls, and roofs) impact on heating and cooling energy. Lighting performance was evaluated by the frequency and magnitude at which natural light levels deviated from a desired range. To ensure the accuracy of results, a method of thermal model calibration was developed based on room temperature responses to various weather conditions. The model used for simulation-based optimization was first calibrated to measured values, of the building it represented, such that predicted and measured hourly room temperatures (°F) deviated by an RMSE of 0.82 on hot and cold days. Optimization results show that thermal and lighting performance can be significantly improved from an initial design and the associated Pareto front aids evaluation of trade-offs between the two.
590
$a
School code: 0694.
650
4
$a
Engineering.
$3
586835
650
4
$a
Architectural engineering.
$3
3174102
650
4
$a
Systems science.
$3
3168411
690
$a
0537
690
$a
0462
690
$a
0790
710
2
$a
The University of North Carolina at Charlotte.
$b
Infrastructure and Environmental Systems.
$3
3191401
773
0
$t
Dissertation Abstracts International
$g
77-05B(E).
790
$a
0694
791
$a
Ph.D.
792
$a
2015
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3744312
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9308845
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入