語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Applications of Statistical Modeling...
~
Perlmutter, David Simon.
FindBook
Google Book
Amazon
博客來
Applications of Statistical Modeling in Iterative CT Image Reconstruction.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Applications of Statistical Modeling in Iterative CT Image Reconstruction./
作者:
Perlmutter, David Simon.
面頁冊數:
49 p.
附註:
Source: Masters Abstracts International, Volume: 54-04.
Contained By:
Masters Abstracts International54-04(E).
標題:
Electrical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1586388
ISBN:
9781321679069
Applications of Statistical Modeling in Iterative CT Image Reconstruction.
Perlmutter, David Simon.
Applications of Statistical Modeling in Iterative CT Image Reconstruction.
- 49 p.
Source: Masters Abstracts International, Volume: 54-04.
Thesis (Master's)--University of Washington, 2015.
Traditionally, x-ray CT images are produced by an algorithm called filtered back projection, or FBP. FBP is an analytical solution to the idealized CT image reconstruction problem, the inverse problem of turning raw x-ray measurements into a full 3-dimensional (3D) image, and is derived assuming a continuous set of noiseless measurements. However real CT data are noisy and biased, especially so if the scans are performed at low x-ray dose, and advanced statistical estimation techniques have been shown to produce higher quality images than FBP. This work presents two applications of statistical modeling in CT image reconstruction. The first application discusses the statistics of CT data noise, and compares the performance of several common models for estimation in a simplified 1D experiment. The second application concerns modeling temporal CT data, in which the measured data typically contain redundancies. It proposes an estimation method that exploits these redundancies to address two key challenges in CT image reconstruction: reducing noise and lowering computation time. We demonstrate this noise reduction analytically and through experimental simulations. In addition, a third study validates the use of the statistical models used in this work by comparing them to measured data from a clinical CT scanner. Overall, these methods contribute to the methodology of statistical CT image reconstruction to enable ultra-low dose x-ray CT imaging.
ISBN: 9781321679069Subjects--Topical Terms:
649834
Electrical engineering.
Applications of Statistical Modeling in Iterative CT Image Reconstruction.
LDR
:02348nmm a2200289 4500
001
2068630
005
20160428074912.5
008
170521s2015 ||||||||||||||||| ||eng d
020
$a
9781321679069
035
$a
(MiAaPQ)AAI1586388
035
$a
AAI1586388
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Perlmutter, David Simon.
$3
3183584
245
1 0
$a
Applications of Statistical Modeling in Iterative CT Image Reconstruction.
300
$a
49 p.
500
$a
Source: Masters Abstracts International, Volume: 54-04.
500
$a
Advisers: Adam Alessio; Paul Kinahan.
502
$a
Thesis (Master's)--University of Washington, 2015.
520
$a
Traditionally, x-ray CT images are produced by an algorithm called filtered back projection, or FBP. FBP is an analytical solution to the idealized CT image reconstruction problem, the inverse problem of turning raw x-ray measurements into a full 3-dimensional (3D) image, and is derived assuming a continuous set of noiseless measurements. However real CT data are noisy and biased, especially so if the scans are performed at low x-ray dose, and advanced statistical estimation techniques have been shown to produce higher quality images than FBP. This work presents two applications of statistical modeling in CT image reconstruction. The first application discusses the statistics of CT data noise, and compares the performance of several common models for estimation in a simplified 1D experiment. The second application concerns modeling temporal CT data, in which the measured data typically contain redundancies. It proposes an estimation method that exploits these redundancies to address two key challenges in CT image reconstruction: reducing noise and lowering computation time. We demonstrate this noise reduction analytically and through experimental simulations. In addition, a third study validates the use of the statistical models used in this work by comparing them to measured data from a clinical CT scanner. Overall, these methods contribute to the methodology of statistical CT image reconstruction to enable ultra-low dose x-ray CT imaging.
590
$a
School code: 0250.
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Biblical studies.
$3
2122820
650
4
$a
Medical imaging.
$3
3172799
690
$a
0544
690
$a
0321
690
$a
0574
710
2
$a
University of Washington.
$b
Engineering.
$3
3183585
773
0
$t
Masters Abstracts International
$g
54-04(E).
790
$a
0250
791
$a
Master's
792
$a
2015
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1586388
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9301498
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入