語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Stories in bone still told: Digitiza...
~
Henson, Kristy D.
FindBook
Google Book
Amazon
博客來
Stories in bone still told: Digitization and replication of the Clover site, Fort Ancient human remains.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Stories in bone still told: Digitization and replication of the Clover site, Fort Ancient human remains./
作者:
Henson, Kristy D.
面頁冊數:
95 p.
附註:
Source: Masters Abstracts International, Volume: 54-04.
Contained By:
Masters Abstracts International54-04(E).
標題:
Morphology. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1587050
ISBN:
9781321701531
Stories in bone still told: Digitization and replication of the Clover site, Fort Ancient human remains.
Henson, Kristy D.
Stories in bone still told: Digitization and replication of the Clover site, Fort Ancient human remains.
- 95 p.
Source: Masters Abstracts International, Volume: 54-04.
Thesis (M.S.)--Marshall University, 2015.
This item must not be sold to any third party vendors.
Human skeletal analysis is a sensitive subject in North America. Laws and regulations make it difficult to use remains to characterize native populations. Recent technologies like three-dimensional (3D) scanning and 3D printing have the potential to solve this dilemma. I assessed this methodology by comparing processing time, accuracy and costs of a medical computer tomography (CT) scanners and an Artec Eva portable 3D surface scanner. Using both methodologies I digitized one individual uncovered during an archaeological excavation in Cabell County, West Virginia. Replicas were created on a ZPrinter 250 3D printer. I hypothesized that the Artec Eva will create digital replicas with <5% error based on Buikstra & Ubelaker standard osteometric measurements. This was tested by comparison of measurements from the material and CT data. I also hypothesized that the ZPrinter will create replicas of <5% error. Results show that larger bones recorded by the Artec Eva have 5% error. CT images yielded <5% error. The ZPrinter also yielded <5% error. The Artec Eva will be sufficient for large element replication, but the CT machine is still a preferable means of skeletal replication.
ISBN: 9781321701531Subjects--Topical Terms:
591167
Morphology.
Stories in bone still told: Digitization and replication of the Clover site, Fort Ancient human remains.
LDR
:02273nmm a2200337 4500
001
2066419
005
20151106144856.5
008
170521s2015 ||||||||||||||||| ||eng d
020
$a
9781321701531
035
$a
(MiAaPQ)AAI1587050
035
$a
AAI1587050
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Henson, Kristy D.
$3
3181210
245
1 0
$a
Stories in bone still told: Digitization and replication of the Clover site, Fort Ancient human remains.
300
$a
95 p.
500
$a
Source: Masters Abstracts International, Volume: 54-04.
500
$a
Adviser: Frank Robin O'Keefe.
502
$a
Thesis (M.S.)--Marshall University, 2015.
506
$a
This item must not be sold to any third party vendors.
506
$a
This item must not be added to any third party search indexes.
520
$a
Human skeletal analysis is a sensitive subject in North America. Laws and regulations make it difficult to use remains to characterize native populations. Recent technologies like three-dimensional (3D) scanning and 3D printing have the potential to solve this dilemma. I assessed this methodology by comparing processing time, accuracy and costs of a medical computer tomography (CT) scanners and an Artec Eva portable 3D surface scanner. Using both methodologies I digitized one individual uncovered during an archaeological excavation in Cabell County, West Virginia. Replicas were created on a ZPrinter 250 3D printer. I hypothesized that the Artec Eva will create digital replicas with <5% error based on Buikstra & Ubelaker standard osteometric measurements. This was tested by comparison of measurements from the material and CT data. I also hypothesized that the ZPrinter will create replicas of <5% error. Results show that larger bones recorded by the Artec Eva have 5% error. CT images yielded <5% error. The ZPrinter also yielded <5% error. The Artec Eva will be sufficient for large element replication, but the CT machine is still a preferable means of skeletal replication.
590
$a
School code: 0817.
650
4
$a
Morphology.
$3
591167
650
4
$a
Archaeology.
$3
558412
650
4
$a
Physical anthropology.
$3
518358
650
4
$a
Native American studies.
$3
2122730
650
4
$a
Computer science.
$3
523869
690
$a
0287
690
$a
0324
690
$a
0327
690
$a
0740
690
$a
0984
710
2
$a
Marshall University.
$b
Biological Sciences.
$3
1685256
773
0
$t
Masters Abstracts International
$g
54-04(E).
790
$a
0817
791
$a
M.S.
792
$a
2015
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1587050
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9299129
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入