語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
An evaluation of sedation level usin...
~
Grey, Paula Michelle.
FindBook
Google Book
Amazon
博客來
An evaluation of sedation level using bispectral index (bis) and correlated adverse events in patients undergoing colonoscopies.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
An evaluation of sedation level using bispectral index (bis) and correlated adverse events in patients undergoing colonoscopies./
作者:
Grey, Paula Michelle.
其他作者:
Poziombke, Jenna Lee
面頁冊數:
116 p.
附註:
Source: Masters Abstracts International, Volume: 52-06.
Contained By:
Masters Abstracts International52-06(E).
標題:
Nursing. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1555360
ISBN:
9781303876776
An evaluation of sedation level using bispectral index (bis) and correlated adverse events in patients undergoing colonoscopies.
Grey, Paula Michelle.
An evaluation of sedation level using bispectral index (bis) and correlated adverse events in patients undergoing colonoscopies.
- 116 p.
Source: Masters Abstracts International, Volume: 52-06.
Thesis (M.S.)--Western Carolina University, 2014.
This item must not be sold to any third party vendors.
The purpose of this prospective, observational study was to provide data for anesthesia providers on current sedation practices during elective colonoscopies. This included determining the incidence of general anesthesia (GA) and the presence or absence of correlated adverse events. Additionally, this research considered if patients who are commonly consented for a MAC anesthetic should be more appropriately consented for GA. Participants (N = 39) consisted of a convenience sampling of physical status (PS) I, II, and III patients scheduled for elective colonoscopies and undergoing sedation with propofol. Data was collected by researchers over a four-week period at a non-teaching rural hospital in Western North Carolina. A bispectral index (BIS) monitor was used to monitor the depth of sedation and values were utilized to determine possible correlated adverse events. Statistical analysis showed that 100% (39/39) of patients reached levels of GA (i.e., BIS ≤ 60) at some point during their procedure. Variables that showed a significant correlation with the occurrence of GA were smaller body mass index (BMI) (r = -.42, r2 = .17, p = .008), longer length of procedure (r = .85, r2 = .72, p < .001), and the number of minutes patients experienced an absent end tidal carbon dioxide (ETCO2) (i.e., apnea) waveform (r = .49, r2 = .24, p = .002). Additionally, greater BMI correlated with a greater nadir BIS value obtained throughout the entire procedure (r = .54, r2 = .29, p < .001), and was found to correlate with less time at BIS values ≤ 40 (r = -.51, r2 = .26, p < .001). Longer procedures correlated with more minutes spent with BIS values ≤ 40 (r = .43, r2 = .18, p = .007), and more minutes with absent ETCO2 waveform (r = .52, r2 = .27, p = .001); however, these findings were clinically insignificant since only one absent ETCO2 waveform actually resulted in a decrease in saturation of peripheral oxygen (SpO2) to ≤ 90% (i.e., hypoxia), which quickly resolved with a chin lift. Additionally, the number of minutes with SpO2 ≤ 90% was not significantly correlated with the minutes of GA (r = -.17, r2 = .03, p = .299). The results of this study indicate, in patients scheduled for colonoscopies who are consented for IV GA, it is common for anesthesia providers to consistently deliver a level of sedation concordant with GA. The significance of this finding relates to the pre-study clinical observation, that endoscopic patients being consented for anesthesia designated as MAC with IV sedation, actually demonstrate intraoperative signs of GA similar to what were observed in this study. Future studies are warranted to determine the frequency of the various forms of anesthesia consent obtained for elective colonoscopies, along with research that assesses anesthetic depth with BIS monitoring in patients consented for MAC with IV sedation. Such research would help to further enhance patient safety and address potential medical legal concerns.
ISBN: 9781303876776Subjects--Topical Terms:
528444
Nursing.
An evaluation of sedation level using bispectral index (bis) and correlated adverse events in patients undergoing colonoscopies.
LDR
:03995nmm a2200301 4500
001
2059002
005
20150724093927.5
008
170521s2014 ||||||||||||||||| ||eng d
020
$a
9781303876776
035
$a
(MiAaPQ)AAI1555360
035
$a
AAI1555360
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Grey, Paula Michelle.
$3
3173014
245
1 3
$a
An evaluation of sedation level using bispectral index (bis) and correlated adverse events in patients undergoing colonoscopies.
300
$a
116 p.
500
$a
Source: Masters Abstracts International, Volume: 52-06.
500
$a
Adviser: Mark A. Kossick.
502
$a
Thesis (M.S.)--Western Carolina University, 2014.
506
$a
This item must not be sold to any third party vendors.
520
$a
The purpose of this prospective, observational study was to provide data for anesthesia providers on current sedation practices during elective colonoscopies. This included determining the incidence of general anesthesia (GA) and the presence or absence of correlated adverse events. Additionally, this research considered if patients who are commonly consented for a MAC anesthetic should be more appropriately consented for GA. Participants (N = 39) consisted of a convenience sampling of physical status (PS) I, II, and III patients scheduled for elective colonoscopies and undergoing sedation with propofol. Data was collected by researchers over a four-week period at a non-teaching rural hospital in Western North Carolina. A bispectral index (BIS) monitor was used to monitor the depth of sedation and values were utilized to determine possible correlated adverse events. Statistical analysis showed that 100% (39/39) of patients reached levels of GA (i.e., BIS ≤ 60) at some point during their procedure. Variables that showed a significant correlation with the occurrence of GA were smaller body mass index (BMI) (r = -.42, r2 = .17, p = .008), longer length of procedure (r = .85, r2 = .72, p < .001), and the number of minutes patients experienced an absent end tidal carbon dioxide (ETCO2) (i.e., apnea) waveform (r = .49, r2 = .24, p = .002). Additionally, greater BMI correlated with a greater nadir BIS value obtained throughout the entire procedure (r = .54, r2 = .29, p < .001), and was found to correlate with less time at BIS values ≤ 40 (r = -.51, r2 = .26, p < .001). Longer procedures correlated with more minutes spent with BIS values ≤ 40 (r = .43, r2 = .18, p = .007), and more minutes with absent ETCO2 waveform (r = .52, r2 = .27, p = .001); however, these findings were clinically insignificant since only one absent ETCO2 waveform actually resulted in a decrease in saturation of peripheral oxygen (SpO2) to ≤ 90% (i.e., hypoxia), which quickly resolved with a chin lift. Additionally, the number of minutes with SpO2 ≤ 90% was not significantly correlated with the minutes of GA (r = -.17, r2 = .03, p = .299). The results of this study indicate, in patients scheduled for colonoscopies who are consented for IV GA, it is common for anesthesia providers to consistently deliver a level of sedation concordant with GA. The significance of this finding relates to the pre-study clinical observation, that endoscopic patients being consented for anesthesia designated as MAC with IV sedation, actually demonstrate intraoperative signs of GA similar to what were observed in this study. Future studies are warranted to determine the frequency of the various forms of anesthesia consent obtained for elective colonoscopies, along with research that assesses anesthetic depth with BIS monitoring in patients consented for MAC with IV sedation. Such research would help to further enhance patient safety and address potential medical legal concerns.
590
$a
School code: 1373.
650
4
$a
Nursing.
$3
528444
650
4
$a
Health sciences.
$3
3168359
650
4
$a
Medicine.
$3
641104
690
$a
0569
690
$a
0566
690
$a
0564
700
1 0
$a
Poziombke, Jenna Lee
$e
joint author
$3
3173015
710
2
$a
Western Carolina University.
$b
Nursing.
$3
1035351
773
0
$t
Masters Abstracts International
$g
52-06(E).
790
$a
1373
791
$a
M.S.
792
$a
2014
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1555360
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9291660
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入