內容註:
Introduction -- Site planning: Room Planning -- RF Protection -- Energy Supply -- Cooling Supply -- magnet Installation -- Safety Considerations: Static Field -- Gradient Field -- RF Field -- Coils: Solenoid / Helmholtz Coils -- Send-/Receive Coils -- Phased Array Coils -- Multi-Channel Technology -- Imaging Technique: k-space -- Image resolution -- Signal-Noise Ratio / Contract-Noise Ratio -- Imaging time -- Spin Echo -- Fast Spin Echo -- Fast Gradient Echo -- Hybrid Imaging -- 3D Imaging -- Gradient Performance -- Fat saturation -- Diffusion Imaging -- Angiographic techniques -- Contrast Agents -- Image Quality Optimization: Number of excitations -- Slice Thickness -- Slice profile -- Interlacing -- Slice Orientation -- Field of view -- Matrix -- Partial Fourrier -- Interpolation -- Parallel Imaging -- Artifacts -- Postprocessing -- Clinical Imaging: Head -- Spine -- Joints -- Vascular Imaging -- Neck -- Thorax -- Abdomen -- Functional Imaging -- Cardiac Imaging -- Future Developments.
Contained By:
Springer eBooks
標題:
Magnetic resonance imaging. -
電子資源:
http://dx.doi.org/10.1007/978-3-319-16516-5
ISBN:
9783319165165$q(electronic bk.)
Clinical low field strength magnetic resonance imaging = a practical guide to accessible MRI /
Klein, Hans-Martin.
Clinical low field strength magnetic resonance imaging
a practical guide to accessible MRI /[electronic resource] :by Hans-Martin Klein. - Cham :Springer International Publishing :2016. - xv, 156 p. :ill., digital ;24 cm.
Introduction -- Site planning: Room Planning -- RF Protection -- Energy Supply -- Cooling Supply -- magnet Installation -- Safety Considerations: Static Field -- Gradient Field -- RF Field -- Coils: Solenoid / Helmholtz Coils -- Send-/Receive Coils -- Phased Array Coils -- Multi-Channel Technology -- Imaging Technique: k-space -- Image resolution -- Signal-Noise Ratio / Contract-Noise Ratio -- Imaging time -- Spin Echo -- Fast Spin Echo -- Fast Gradient Echo -- Hybrid Imaging -- 3D Imaging -- Gradient Performance -- Fat saturation -- Diffusion Imaging -- Angiographic techniques -- Contrast Agents -- Image Quality Optimization: Number of excitations -- Slice Thickness -- Slice profile -- Interlacing -- Slice Orientation -- Field of view -- Matrix -- Partial Fourrier -- Interpolation -- Parallel Imaging -- Artifacts -- Postprocessing -- Clinical Imaging: Head -- Spine -- Joints -- Vascular Imaging -- Neck -- Thorax -- Abdomen -- Functional Imaging -- Cardiac Imaging -- Future Developments.
This book covers all aspects of low field MRI, describing its advantages, problems, and prerequisites. Individual chapters are devoted to site planning, safety considerations, coils, imaging technique, image quality optimization, the imaging of different anatomic regions, and likely future developments. The factors that must be borne in mind when selecting a low field system are clearly identified, and detailed attention is paid to the applications for which such a system is adequate. The focus on high field systems has led to a situation where only a few systems with field strengths lower than 0.5 T survive. Some of these systems possess high field features such as multichannel coils and strong gradients; furthermore, sequence technology and image processing techniques taken from higher field strength systems have resulted in impressive imaging capabilities. While 1.5-T systems will probably continue to remain the standard, low field systems offer advantages such as the feasibility of dynamic joint examinations, improvement of T1 contrast, reduction of "missile effects", and decreased radiofrequency exposure. Low field strength MRI consequently has the potential to contribute to optimal patient management and, given comparable image quality, its application may become an issue of patient safety. This book will be an invaluable asset to all who are involved in planning and/or running a low field strength MRI facility.
ISBN: 9783319165165$q(electronic bk.)
Standard No.: 10.1007/978-3-319-16516-5doiSubjects--Topical Terms:
554355
Magnetic resonance imaging.
LC Class. No.: RC78.7.N83
Dewey Class. No.: 616.0754
Clinical low field strength magnetic resonance imaging = a practical guide to accessible MRI /
LDR
:03408nmm a2200313 a 4500
001
2029317
003
DE-He213
005
20160726151722.0
006
m d
007
cr nn 008maaau
008
160908s2016 gw s 0 eng d
020
$a
9783319165165$q(electronic bk.)
020
$a
9783319165158$q(paper)
024
7
$a
10.1007/978-3-319-16516-5
$2
doi
035
$a
978-3-319-16516-5
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
RC78.7.N83
072
7
$a
MMPH
$2
bicssc
072
7
$a
MED019000
$2
bisacsh
082
0 4
$a
616.0754
$2
23
090
$a
RC78.7.N83
$b
K64 2016
100
1
$a
Klein, Hans-Martin.
$3
2180235
245
1 0
$a
Clinical low field strength magnetic resonance imaging
$h
[electronic resource] :
$b
a practical guide to accessible MRI /
$c
by Hans-Martin Klein.
260
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2016.
300
$a
xv, 156 p. :
$b
ill., digital ;
$c
24 cm.
505
0
$a
Introduction -- Site planning: Room Planning -- RF Protection -- Energy Supply -- Cooling Supply -- magnet Installation -- Safety Considerations: Static Field -- Gradient Field -- RF Field -- Coils: Solenoid / Helmholtz Coils -- Send-/Receive Coils -- Phased Array Coils -- Multi-Channel Technology -- Imaging Technique: k-space -- Image resolution -- Signal-Noise Ratio / Contract-Noise Ratio -- Imaging time -- Spin Echo -- Fast Spin Echo -- Fast Gradient Echo -- Hybrid Imaging -- 3D Imaging -- Gradient Performance -- Fat saturation -- Diffusion Imaging -- Angiographic techniques -- Contrast Agents -- Image Quality Optimization: Number of excitations -- Slice Thickness -- Slice profile -- Interlacing -- Slice Orientation -- Field of view -- Matrix -- Partial Fourrier -- Interpolation -- Parallel Imaging -- Artifacts -- Postprocessing -- Clinical Imaging: Head -- Spine -- Joints -- Vascular Imaging -- Neck -- Thorax -- Abdomen -- Functional Imaging -- Cardiac Imaging -- Future Developments.
520
$a
This book covers all aspects of low field MRI, describing its advantages, problems, and prerequisites. Individual chapters are devoted to site planning, safety considerations, coils, imaging technique, image quality optimization, the imaging of different anatomic regions, and likely future developments. The factors that must be borne in mind when selecting a low field system are clearly identified, and detailed attention is paid to the applications for which such a system is adequate. The focus on high field systems has led to a situation where only a few systems with field strengths lower than 0.5 T survive. Some of these systems possess high field features such as multichannel coils and strong gradients; furthermore, sequence technology and image processing techniques taken from higher field strength systems have resulted in impressive imaging capabilities. While 1.5-T systems will probably continue to remain the standard, low field systems offer advantages such as the feasibility of dynamic joint examinations, improvement of T1 contrast, reduction of "missile effects", and decreased radiofrequency exposure. Low field strength MRI consequently has the potential to contribute to optimal patient management and, given comparable image quality, its application may become an issue of patient safety. This book will be an invaluable asset to all who are involved in planning and/or running a low field strength MRI facility.
650
0
$a
Magnetic resonance imaging.
$3
554355
650
0
$a
Nuclear magnetic resonance.
$3
558175
650
1 4
$a
Medicine & Public Health.
$3
890906
650
2 4
$a
Diagnostic Radiology.
$3
891111
650
2 4
$a
Surgery.
$3
707153
650
2 4
$a
Neurology.
$3
588698
710
2
$a
SpringerLink (Online service)
$3
836513
773
0
$t
Springer eBooks
856
4 0
$u
http://dx.doi.org/10.1007/978-3-319-16516-5
950
$a
Medicine (Springer-11650)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9276581
電子資源
11.線上閱覽_V
電子書
EB RC78.7.N83 K64 2016
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入