Validation of hand-held bioelectrical impedance analysis for the assessment of body fat in young and old adults.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Validation of hand-held bioelectrical impedance analysis for the assessment of body fat in young and old adults./
作者:
Wheeler, Lynn.
面頁冊數:
159 p.
附註:
Source: Masters Abstracts International, Volume: 51-05.
Contained By:
Masters Abstracts International51-05(E).
標題:
Health Sciences, Recreation. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1534358
ISBN:
9781267939098
Validation of hand-held bioelectrical impedance analysis for the assessment of body fat in young and old adults.
Wheeler, Lynn.
Validation of hand-held bioelectrical impedance analysis for the assessment of body fat in young and old adults.
- 159 p.
Source: Masters Abstracts International, Volume: 51-05.
Thesis (M.S.)--The University of Wisconsin - Milwaukee, 2012.
Because of health concerns surrounding overweight and obesity, many individuals, health clubs, and physicians have begun using portable measures of body fat (BF) that are inexpensive and easy-to-use. Based on measures from these devices, health-related decisions are made and progress during fitness and/or dietary programs is tracked. However, accuracy of portable BF devices can be questionable, especially in free-living settings. Purpose: The purpose of this study is to evaluate the validity and reliability of a commercially-available, hand-held bioelectrical impedance analysis (BIA) device as a measure of BF during a controlled laboratory condition and a free-living condition. Methods: A total of 91 White individuals (41 men, 50 women), ages 19-39 (young group) and 55-75 years (old group), completed the study. During the laboratory visit, body fat measures from the hand-held BIA and to two additional methods, DEXA and tetrapolar BIA, were compared across age and sex when pre-testing guidelines were followed. Participants were then asked to take the hand-held BIA home to complete four free-living BF% measures. A mixed between by within design comparing sex and age groups (between groups variables) across hand-held BIA, tetrapolar BIA and DEXA measurements (within groups variable) was performed to determine whether differences among body fat assessment devices exist. Post-hoc planned comparisons were performed to determine which devices are different in assessing BF among the hand-held BIA, the tetrapolar BIA and the DEXA. Repeated-measures ANOVA with post hoc comparisons were performed to determine differences in BF measures among hand-held BF measures over the free-living day. Results: BF results from the hand-held BIA were significant from DEXA and tetrapolar BIA for the female and young groups. Specifically in the female group, the hand-held BIA underestimated %BF by 2.7 percentage points compared to the DEXA. The tetrapolar BIA also underestimated %BF by 2.5 percentage points compared to the DEXA. In the young group, the hand-held BIA underestimated %BF by 3.5 percentage points compared to the DEXA. The tetrapolar BIA also underestimated %BF by 3.8 percentage points compared to the DEXA. In the male and old groups, there was no significant difference between BF measures from DEXA and hand-held BIA, but significant differences were present between the tetrapolar BIA and hand-held BIA. The hand-held BIA overestimated %BF by 2.6 and 1.9 percentage points in the male and old groups, respectively, as compared to the tetrapolar BIA. Despite the fact that there were statistically significant differences in BF measures from the hand-held BIA and the DEXA, these differences did not exceed the clinically acceptable level (+/-3.5%). Conclusion: The hand-held BIA device is designed for use by individuals to assess BF level. Although means were not clinically different between the hand-held device and DEXA in all groups, difference scores between devices suggest that the hand-held BIA is not a valid device on an individual level and, therefore, not recommended for the assessment of %BF.
ISBN: 9781267939098Subjects--Topical Terms:
1018003
Health Sciences, Recreation.
Validation of hand-held bioelectrical impedance analysis for the assessment of body fat in young and old adults.
LDR
:04031nam a2200277 4500
001
1968954
005
20141219110759.5
008
150210s2012 ||||||||||||||||| ||eng d
020
$a
9781267939098
035
$a
(MiAaPQ)AAI1534358
035
$a
AAI1534358
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Wheeler, Lynn.
$3
2106193
245
1 0
$a
Validation of hand-held bioelectrical impedance analysis for the assessment of body fat in young and old adults.
300
$a
159 p.
500
$a
Source: Masters Abstracts International, Volume: 51-05.
500
$a
Adviser: Ann M. Swartz.
502
$a
Thesis (M.S.)--The University of Wisconsin - Milwaukee, 2012.
520
$a
Because of health concerns surrounding overweight and obesity, many individuals, health clubs, and physicians have begun using portable measures of body fat (BF) that are inexpensive and easy-to-use. Based on measures from these devices, health-related decisions are made and progress during fitness and/or dietary programs is tracked. However, accuracy of portable BF devices can be questionable, especially in free-living settings. Purpose: The purpose of this study is to evaluate the validity and reliability of a commercially-available, hand-held bioelectrical impedance analysis (BIA) device as a measure of BF during a controlled laboratory condition and a free-living condition. Methods: A total of 91 White individuals (41 men, 50 women), ages 19-39 (young group) and 55-75 years (old group), completed the study. During the laboratory visit, body fat measures from the hand-held BIA and to two additional methods, DEXA and tetrapolar BIA, were compared across age and sex when pre-testing guidelines were followed. Participants were then asked to take the hand-held BIA home to complete four free-living BF% measures. A mixed between by within design comparing sex and age groups (between groups variables) across hand-held BIA, tetrapolar BIA and DEXA measurements (within groups variable) was performed to determine whether differences among body fat assessment devices exist. Post-hoc planned comparisons were performed to determine which devices are different in assessing BF among the hand-held BIA, the tetrapolar BIA and the DEXA. Repeated-measures ANOVA with post hoc comparisons were performed to determine differences in BF measures among hand-held BF measures over the free-living day. Results: BF results from the hand-held BIA were significant from DEXA and tetrapolar BIA for the female and young groups. Specifically in the female group, the hand-held BIA underestimated %BF by 2.7 percentage points compared to the DEXA. The tetrapolar BIA also underestimated %BF by 2.5 percentage points compared to the DEXA. In the young group, the hand-held BIA underestimated %BF by 3.5 percentage points compared to the DEXA. The tetrapolar BIA also underestimated %BF by 3.8 percentage points compared to the DEXA. In the male and old groups, there was no significant difference between BF measures from DEXA and hand-held BIA, but significant differences were present between the tetrapolar BIA and hand-held BIA. The hand-held BIA overestimated %BF by 2.6 and 1.9 percentage points in the male and old groups, respectively, as compared to the tetrapolar BIA. Despite the fact that there were statistically significant differences in BF measures from the hand-held BIA and the DEXA, these differences did not exceed the clinically acceptable level (+/-3.5%). Conclusion: The hand-held BIA device is designed for use by individuals to assess BF level. Although means were not clinically different between the hand-held device and DEXA in all groups, difference scores between devices suggest that the hand-held BIA is not a valid device on an individual level and, therefore, not recommended for the assessment of %BF.
590
$a
School code: 0263.
650
4
$a
Health Sciences, Recreation.
$3
1018003
650
4
$a
Health Sciences, General.
$3
1017817
690
$a
0575
690
$a
0566
710
2
$a
The University of Wisconsin - Milwaukee.
$b
Kinesiology.
$3
2102596
773
0
$t
Masters Abstracts International
$g
51-05(E).
790
$a
0263
791
$a
M.S.
792
$a
2012
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1534358
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9263961
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入