語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
A Fast, Low-Cost, Computer Vision-Ba...
~
Dockter, Rodney Lee II.
FindBook
Google Book
Amazon
博客來
A Fast, Low-Cost, Computer Vision-Based Approach For Tracking Surgical Tools.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
A Fast, Low-Cost, Computer Vision-Based Approach For Tracking Surgical Tools./
作者:
Dockter, Rodney Lee II.
面頁冊數:
214 p.
附註:
Source: Masters Abstracts International, Volume: 52-03.
Contained By:
Masters Abstracts International52-03(E).
標題:
Engineering, General. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1547852
ISBN:
9781303507755
A Fast, Low-Cost, Computer Vision-Based Approach For Tracking Surgical Tools.
Dockter, Rodney Lee II.
A Fast, Low-Cost, Computer Vision-Based Approach For Tracking Surgical Tools.
- 214 p.
Source: Masters Abstracts International, Volume: 52-03.
Thesis (M.S.M.E.)--University of Minnesota, 2013.
The number of Robot-Assisted Minimally Invasive Surgery (RMIS) procedures has grown immensely in recent years. Like Minimally Invasive Surgeries (MIS), RMIS procedures provide improved patient recovery time and reduced trauma due to smaller incisions relative to traditional open procedures. Given the rise in RMIS procedures, several organizations and companies have made efforts to develop training tasks and certification criteria for the da Vinci robot. Each training task is evaluated with various quantitative criteria such as completion time, total tool path length and economy of motion, which is a measurement of deviation from an `ideal' path. All of these metrics can benefit greatly from an accurate, inexpensive and modular tool tracking system that requires no modification to the existing robot. While the da Vinci uses joint kinematics to calculate the tool tip position and movement internally, this data is not openly available to users. Even if this data was open to researchers, the accuracy of kinematic calculations of end effector position suffers from compliance in the joints and links of the robot as well as finite uncertainties in the sensors. In order to and an accurate, available and low-cost alternative to tool tip localization, we have developed a computer vision based design for surgical tool tracking. Vision systems have the added benefit of being relatively low cost with typical high resolution webcams costing around 50 dollars. We employ a joint geometric constraint - Hough transform method for locating the tool shaft and subsequently the tool tip. The tool tracking algorithm presented was evaluated on both an experimental webcam setup as well as a da Vinci Endoscope used in real surgeries. This system can accurately locate the tip of a robotic surgical tool in real time with no augmentation of the tool. The proposed algorithm was evaluated in terms of speed and accuracy. This method achieves an average 3D positional tracking accuracy of 3.05 mm and at 25.86 frames per second for the experimental webcam setup. For the da Vinci endoscope setup, this solution achieves a frame rate of 26.99 FPS with an average tracking accuracy of 8.68 mm in 3D and 11.88 mm in 2D. The system demonstrated successful tracking of RMIS tools from captured video of a real patient case.
ISBN: 9781303507755Subjects--Topical Terms:
1020744
Engineering, General.
A Fast, Low-Cost, Computer Vision-Based Approach For Tracking Surgical Tools.
LDR
:03203nam a2200289 4500
001
1967134
005
20141112080132.5
008
150210s2013 ||||||||||||||||| ||eng d
020
$a
9781303507755
035
$a
(MiAaPQ)AAI1547852
035
$a
AAI1547852
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Dockter, Rodney Lee II.
$3
2104074
245
1 2
$a
A Fast, Low-Cost, Computer Vision-Based Approach For Tracking Surgical Tools.
300
$a
214 p.
500
$a
Source: Masters Abstracts International, Volume: 52-03.
500
$a
Adviser: Timothy M. Kowalewski.
502
$a
Thesis (M.S.M.E.)--University of Minnesota, 2013.
520
$a
The number of Robot-Assisted Minimally Invasive Surgery (RMIS) procedures has grown immensely in recent years. Like Minimally Invasive Surgeries (MIS), RMIS procedures provide improved patient recovery time and reduced trauma due to smaller incisions relative to traditional open procedures. Given the rise in RMIS procedures, several organizations and companies have made efforts to develop training tasks and certification criteria for the da Vinci robot. Each training task is evaluated with various quantitative criteria such as completion time, total tool path length and economy of motion, which is a measurement of deviation from an `ideal' path. All of these metrics can benefit greatly from an accurate, inexpensive and modular tool tracking system that requires no modification to the existing robot. While the da Vinci uses joint kinematics to calculate the tool tip position and movement internally, this data is not openly available to users. Even if this data was open to researchers, the accuracy of kinematic calculations of end effector position suffers from compliance in the joints and links of the robot as well as finite uncertainties in the sensors. In order to and an accurate, available and low-cost alternative to tool tip localization, we have developed a computer vision based design for surgical tool tracking. Vision systems have the added benefit of being relatively low cost with typical high resolution webcams costing around 50 dollars. We employ a joint geometric constraint - Hough transform method for locating the tool shaft and subsequently the tool tip. The tool tracking algorithm presented was evaluated on both an experimental webcam setup as well as a da Vinci Endoscope used in real surgeries. This system can accurately locate the tip of a robotic surgical tool in real time with no augmentation of the tool. The proposed algorithm was evaluated in terms of speed and accuracy. This method achieves an average 3D positional tracking accuracy of 3.05 mm and at 25.86 frames per second for the experimental webcam setup. For the da Vinci endoscope setup, this solution achieves a frame rate of 26.99 FPS with an average tracking accuracy of 8.68 mm in 3D and 11.88 mm in 2D. The system demonstrated successful tracking of RMIS tools from captured video of a real patient case.
590
$a
School code: 0130.
650
4
$a
Engineering, General.
$3
1020744
650
4
$a
Computer Science.
$3
626642
650
4
$a
Engineering, Robotics.
$3
1018454
690
$a
0537
690
$a
0984
690
$a
0771
710
2
$a
University of Minnesota.
$b
Mechanical Engineering.
$3
1020853
773
0
$t
Masters Abstracts International
$g
52-03(E).
790
$a
0130
791
$a
M.S.M.E.
792
$a
2013
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1547852
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9262140
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入