語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Effect of Coating Titanium Implants ...
~
Qari, Maha Rahmatullah.
FindBook
Google Book
Amazon
博客來
Effect of Coating Titanium Implants with Silk on Osseointegration.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Effect of Coating Titanium Implants with Silk on Osseointegration./
作者:
Qari, Maha Rahmatullah.
面頁冊數:
34 p.
附註:
Source: Masters Abstracts International, Volume: 52-03.
Contained By:
Masters Abstracts International52-03(E).
標題:
Health Sciences, Dentistry. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1547329
ISBN:
9781303487781
Effect of Coating Titanium Implants with Silk on Osseointegration.
Qari, Maha Rahmatullah.
Effect of Coating Titanium Implants with Silk on Osseointegration.
- 34 p.
Source: Masters Abstracts International, Volume: 52-03.
Thesis (M.S.)--Tufts University School of Dental Medicine, 2013.
Available in-vitro data suggest that surface modeling of inert titanium with silk enhances its interaction with the biological environment. Furthermore, incorporating arginine-glycine-aspartic acid (RGD) peptides into silk might stimulate the adhesion of fibroblasts leading to an accelerated osseointegration. The purpose of this study was to test the effect of coating implants with RGD-decorated silk on osseointegration in an in-vivo parallel design, randomized controlled trial in an animal model. A total of 18 titanium implants were used. Each animal received 3 coated (test) and 3 uncoated (control) implants placed in their tibiae. Bone samples were collected at 2, 4, and 6 weeks post-implant placement. The percentage of bone-to-implant contact (BIC) was assessed histologically. Different inflammatory cells were identified around each implant to assess the inflammatory response. The BIC in the test group was higher than the control group (82% vs. 62%, p = 0.083) at 2 weeks but lower at 4 weeks (39% vs. 57%, p = 0.275) and 6 weeks (32% vs. 34%, p=1.000), but none of these differences were statistically significant. The number of lymphocytes was higher in the test group at 2, 4, and 6 weeks (p=0.025, 0.034, and 0.025, respectively). Lymphocytes, MN Giant cells and macrophages were also higher in number with statistical significance in the test group across the different time points. Our data suggest that coating implants with RGD decorated silk does not improve the short-term BIC and initiates a higher inflammatory response. However, further studies with larger sample sizes and modified coating protocol, are needed to be performed.
ISBN: 9781303487781Subjects--Topical Terms:
1019378
Health Sciences, Dentistry.
Effect of Coating Titanium Implants with Silk on Osseointegration.
LDR
:02568nam a2200289 4500
001
1965673
005
20141029122149.5
008
150210s2013 ||||||||||||||||| ||eng d
020
$a
9781303487781
035
$a
(MiAaPQ)AAI1547329
035
$a
AAI1547329
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Qari, Maha Rahmatullah.
$3
2102365
245
1 0
$a
Effect of Coating Titanium Implants with Silk on Osseointegration.
300
$a
34 p.
500
$a
Source: Masters Abstracts International, Volume: 52-03.
500
$a
Includes supplementary digital materials.
500
$a
Adviser: Driss Zoukhri.
502
$a
Thesis (M.S.)--Tufts University School of Dental Medicine, 2013.
520
$a
Available in-vitro data suggest that surface modeling of inert titanium with silk enhances its interaction with the biological environment. Furthermore, incorporating arginine-glycine-aspartic acid (RGD) peptides into silk might stimulate the adhesion of fibroblasts leading to an accelerated osseointegration. The purpose of this study was to test the effect of coating implants with RGD-decorated silk on osseointegration in an in-vivo parallel design, randomized controlled trial in an animal model. A total of 18 titanium implants were used. Each animal received 3 coated (test) and 3 uncoated (control) implants placed in their tibiae. Bone samples were collected at 2, 4, and 6 weeks post-implant placement. The percentage of bone-to-implant contact (BIC) was assessed histologically. Different inflammatory cells were identified around each implant to assess the inflammatory response. The BIC in the test group was higher than the control group (82% vs. 62%, p = 0.083) at 2 weeks but lower at 4 weeks (39% vs. 57%, p = 0.275) and 6 weeks (32% vs. 34%, p=1.000), but none of these differences were statistically significant. The number of lymphocytes was higher in the test group at 2, 4, and 6 weeks (p=0.025, 0.034, and 0.025, respectively). Lymphocytes, MN Giant cells and macrophages were also higher in number with statistical significance in the test group across the different time points. Our data suggest that coating implants with RGD decorated silk does not improve the short-term BIC and initiates a higher inflammatory response. However, further studies with larger sample sizes and modified coating protocol, are needed to be performed.
590
$a
School code: 1547.
650
4
$a
Health Sciences, Dentistry.
$3
1019378
650
4
$a
Engineering, Biomedical.
$3
1017684
690
$a
0567
690
$a
0541
710
2
$a
Tufts University School of Dental Medicine.
$b
Periodontology.
$3
2102366
773
0
$t
Masters Abstracts International
$g
52-03(E).
790
$a
1547
791
$a
M.S.
792
$a
2013
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1547329
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9260672
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入