Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Motion Optimized Conformal Microwave...
~
Epstein, Neil R.
Linked to FindBook
Google Book
Amazon
博客來
Motion Optimized Conformal Microwave Imaging for Biomedical Applications.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Motion Optimized Conformal Microwave Imaging for Biomedical Applications./
Author:
Epstein, Neil R.
Description:
214 p.
Notes:
Source: Dissertation Abstracts International, Volume: 75-06(E), Section: B.
Contained By:
Dissertation Abstracts International75-06B(E).
Subject:
Health Sciences, Radiology. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3613688
ISBN:
9781303770425
Motion Optimized Conformal Microwave Imaging for Biomedical Applications.
Epstein, Neil R.
Motion Optimized Conformal Microwave Imaging for Biomedical Applications.
- 214 p.
Source: Dissertation Abstracts International, Volume: 75-06(E), Section: B.
Thesis (Ph.D.)--Dartmouth College, 2013.
Investigations into alternative breast cancer (BC) imaging techniques have become increasingly popular based on the limitations of traditional imaging modalities: X-ray mammography uses ionizing radiation, has limited intrinsic contrast and is associated with high false-positive and false-negative rates. Microwave tomographic imaging (MTI) has the ability to detect a wide range of dielectric property (DP) values, and due to the contrast that exists between the DPs of normal and abnormal breast tissue, MTI has shown promise as an alternative BC imaging modality. This thesis reports on a third generation system currently used in clinical trials at Dartmouth Hitchcock Medical Center. This system's improvements include increased data acquisition speeds and capabilities due to upgraded microwave electronic components and motion control hardware, respectively. Part I of this work will evaluate the system's microwave electronics in terms of channel isolation, system sensitivity and measurement repeatability in an effort to define an optimal operational bandwidth. The system's antenna array is composed of two interwoven sub-arrays (SAs) that can independently move to a number of positions. We have found that incorporating measurement data obtained at larger SA separation spacing during 3D acquisition results in unwanted artifacts in the reconstructed images. S-parameter studies have indicated that signals transmitted at these larger separation distances fall below the noise floor (NF) of the system's receiving channels. Part II of this thesis will focus on analyzing measurement sensitivity as a function of increasing SA spacing. The analysis has resulted in the creation of a motion optimized imaging system; increasing examination speeds by eliminating measurements positions where signals fall below the NF. Additionally, we have seen that our reconstruction algorithm has benefited from the incorporation of boundary information regarding the object under test (OUT). An optical-scanning system that can capture the boundary of the OUT while submerged in the system imaging chamber has been developed and mounted to the new imaging prototype. Conforming the reconstruction property mesh to the boundary of the OUT has increased the accuracy of recovered DPs. Part III of this thesis evaluates the boundary conformed microwave reconstruction process utilizing information obtained from the integrated optical-scanner.
ISBN: 9781303770425Subjects--Topical Terms:
1019076
Health Sciences, Radiology.
Motion Optimized Conformal Microwave Imaging for Biomedical Applications.
LDR
:03342nam a2200289 4500
001
1964661
005
20141010092632.5
008
150210s2013 ||||||||||||||||| ||eng d
020
$a
9781303770425
035
$a
(MiAaPQ)AAI3613688
035
$a
AAI3613688
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Epstein, Neil R.
$3
2101151
245
1 0
$a
Motion Optimized Conformal Microwave Imaging for Biomedical Applications.
300
$a
214 p.
500
$a
Source: Dissertation Abstracts International, Volume: 75-06(E), Section: B.
500
$a
Advisers: Paul M. Meaney; Keith D. Paulsen.
502
$a
Thesis (Ph.D.)--Dartmouth College, 2013.
520
$a
Investigations into alternative breast cancer (BC) imaging techniques have become increasingly popular based on the limitations of traditional imaging modalities: X-ray mammography uses ionizing radiation, has limited intrinsic contrast and is associated with high false-positive and false-negative rates. Microwave tomographic imaging (MTI) has the ability to detect a wide range of dielectric property (DP) values, and due to the contrast that exists between the DPs of normal and abnormal breast tissue, MTI has shown promise as an alternative BC imaging modality. This thesis reports on a third generation system currently used in clinical trials at Dartmouth Hitchcock Medical Center. This system's improvements include increased data acquisition speeds and capabilities due to upgraded microwave electronic components and motion control hardware, respectively. Part I of this work will evaluate the system's microwave electronics in terms of channel isolation, system sensitivity and measurement repeatability in an effort to define an optimal operational bandwidth. The system's antenna array is composed of two interwoven sub-arrays (SAs) that can independently move to a number of positions. We have found that incorporating measurement data obtained at larger SA separation spacing during 3D acquisition results in unwanted artifacts in the reconstructed images. S-parameter studies have indicated that signals transmitted at these larger separation distances fall below the noise floor (NF) of the system's receiving channels. Part II of this thesis will focus on analyzing measurement sensitivity as a function of increasing SA spacing. The analysis has resulted in the creation of a motion optimized imaging system; increasing examination speeds by eliminating measurements positions where signals fall below the NF. Additionally, we have seen that our reconstruction algorithm has benefited from the incorporation of boundary information regarding the object under test (OUT). An optical-scanning system that can capture the boundary of the OUT while submerged in the system imaging chamber has been developed and mounted to the new imaging prototype. Conforming the reconstruction property mesh to the boundary of the OUT has increased the accuracy of recovered DPs. Part III of this thesis evaluates the boundary conformed microwave reconstruction process utilizing information obtained from the integrated optical-scanner.
590
$a
School code: 0059.
650
4
$a
Health Sciences, Radiology.
$3
1019076
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Physics, Electricity and Magnetism.
$3
1019535
690
$a
0574
690
$a
0541
690
$a
0607
710
2
$a
Dartmouth College.
$b
Engineering.
$3
1057396
773
0
$t
Dissertation Abstracts International
$g
75-06B(E).
790
$a
0059
791
$a
Ph.D.
792
$a
2013
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3613688
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9259660
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login