語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Wide Area Power System Islanding Det...
~
Sun, Rui.
FindBook
Google Book
Amazon
博客來
Wide Area Power System Islanding Detection, Classification and State Evaluation Algorithm.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Wide Area Power System Islanding Detection, Classification and State Evaluation Algorithm./
作者:
Sun, Rui.
面頁冊數:
181 p.
附註:
Source: Dissertation Abstracts International, Volume: 75-06(E), Section: B.
Contained By:
Dissertation Abstracts International75-06B(E).
標題:
Engineering, Electronics and Electrical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3585843
ISBN:
9781303788833
Wide Area Power System Islanding Detection, Classification and State Evaluation Algorithm.
Sun, Rui.
Wide Area Power System Islanding Detection, Classification and State Evaluation Algorithm.
- 181 p.
Source: Dissertation Abstracts International, Volume: 75-06(E), Section: B.
Thesis (Ph.D.)--Virginia Polytechnic Institute and State University, 2012.
An islanded power system indicates a geographical and logical detach between a portion of a power system and the major grid, and often accompanies with the loss of system observability. A power system islanding contingency could be one of the most severe consequences of wide-area system failures. It might result in enormous losses to both the power utilities and the consumers. Even those relatively small and stable islanding events may largely disturb the consumers' normal operation in the island. On the other hand, the power consumption in the U.S. has been largely increasing since 1970s with the respect to the bloom of global economy and mass manufacturing, and the daily increased requirements from the modern customers. Along with the extreme weather and natural disaster factors, the century old U.S. power grid is under severely tests for potential islanding disturbances. After 1980s, the invention of synchronized phasor measurement units (PMU) has broadened the horizon for system monitoring, control and protection. Its real time feature and reliable measurements has made possible many online system schemes. The recent revolution of computers and electronic devices enables the implementation of complex methods (such as data mining methods) requiring large databases in power system analysis. The proposed method presented in this dissertation is primarily focused on two studies: one power system islanding contingency detection, identification, classification and state evaluation algorithm using a decision tree algorithm and topology approach, and its application in Dominion Virginia power system; and one optimal PMU placement strategy using a binary integral programming algorithm with the consideration of system islanding and redundancy issues.
ISBN: 9781303788833Subjects--Topical Terms:
626636
Engineering, Electronics and Electrical.
Wide Area Power System Islanding Detection, Classification and State Evaluation Algorithm.
LDR
:02672nam a2200265 4500
001
1962596
005
20140819094515.5
008
150210s2012 ||||||||||||||||| ||eng d
020
$a
9781303788833
035
$a
(MiAaPQ)AAI3585843
035
$a
AAI3585843
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Sun, Rui.
$3
2098688
245
1 0
$a
Wide Area Power System Islanding Detection, Classification and State Evaluation Algorithm.
300
$a
181 p.
500
$a
Source: Dissertation Abstracts International, Volume: 75-06(E), Section: B.
500
$a
Adviser: Virgilio A. Centeno.
502
$a
Thesis (Ph.D.)--Virginia Polytechnic Institute and State University, 2012.
520
$a
An islanded power system indicates a geographical and logical detach between a portion of a power system and the major grid, and often accompanies with the loss of system observability. A power system islanding contingency could be one of the most severe consequences of wide-area system failures. It might result in enormous losses to both the power utilities and the consumers. Even those relatively small and stable islanding events may largely disturb the consumers' normal operation in the island. On the other hand, the power consumption in the U.S. has been largely increasing since 1970s with the respect to the bloom of global economy and mass manufacturing, and the daily increased requirements from the modern customers. Along with the extreme weather and natural disaster factors, the century old U.S. power grid is under severely tests for potential islanding disturbances. After 1980s, the invention of synchronized phasor measurement units (PMU) has broadened the horizon for system monitoring, control and protection. Its real time feature and reliable measurements has made possible many online system schemes. The recent revolution of computers and electronic devices enables the implementation of complex methods (such as data mining methods) requiring large databases in power system analysis. The proposed method presented in this dissertation is primarily focused on two studies: one power system islanding contingency detection, identification, classification and state evaluation algorithm using a decision tree algorithm and topology approach, and its application in Dominion Virginia power system; and one optimal PMU placement strategy using a binary integral programming algorithm with the consideration of system islanding and redundancy issues.
590
$a
School code: 0247.
650
4
$a
Engineering, Electronics and Electrical.
$3
626636
690
$a
0544
710
2
$a
Virginia Polytechnic Institute and State University.
$3
1017496
773
0
$t
Dissertation Abstracts International
$g
75-06B(E).
790
$a
0247
791
$a
Ph.D.
792
$a
2012
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3585843