語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Advancements in selenium speciation,...
~
Roberge, Mark Timothy.
FindBook
Google Book
Amazon
博客來
Advancements in selenium speciation, fast gas analysis and sample preparation procedures for the chemical analysis of real-world samples.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Advancements in selenium speciation, fast gas analysis and sample preparation procedures for the chemical analysis of real-world samples./
作者:
Roberge, Mark Timothy.
面頁冊數:
176 p.
附註:
Source: Dissertation Abstracts International, Volume: 64-09, Section: B, page: 4327.
Contained By:
Dissertation Abstracts International64-09B.
標題:
Engineering, Environmental. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3107191
Advancements in selenium speciation, fast gas analysis and sample preparation procedures for the chemical analysis of real-world samples.
Roberge, Mark Timothy.
Advancements in selenium speciation, fast gas analysis and sample preparation procedures for the chemical analysis of real-world samples.
- 176 p.
Source: Dissertation Abstracts International, Volume: 64-09, Section: B, page: 4327.
Thesis (Ph.D.)--The University of North Dakota, 2003.
The Pulsed Discharge Helium Ionization Detector (PDHID) was compared to the Flame Ionization Detector (FID) and the Thermal Conductivity Detector (TCD) for High Speed Gas Chromatography (HSGC). It was shown that the PDHID is as sensitive as the FID but can be less reproducible. Moreover, the PDHID is more sensitive and more universal than the TCD. The prospect of a portable PDHID was explored but, a required helium purifier uses more power than is feasible for portability. The PDHID was used to detect hydrogen and methane separated from the matrix components of breath samples with over an order of magnitude better sensitivity than methods using an FID or TCD. Limits of detection for dissolved hydrogen and methane using the Rapid Aqueous Sample Extractor (RASE)-GC-PDHID were 7.0 ng/mL and 3.5 ng/mL respectively.Subjects--Topical Terms:
783782
Engineering, Environmental.
Advancements in selenium speciation, fast gas analysis and sample preparation procedures for the chemical analysis of real-world samples.
LDR
:03431nmm 2200325 4500
001
1866116
005
20041220114125.5
008
130614s2003 eng d
035
$a
(UnM)AAI3107191
035
$a
AAI3107191
040
$a
UnM
$c
UnM
100
1
$a
Roberge, Mark Timothy.
$3
1953529
245
1 0
$a
Advancements in selenium speciation, fast gas analysis and sample preparation procedures for the chemical analysis of real-world samples.
300
$a
176 p.
500
$a
Source: Dissertation Abstracts International, Volume: 64-09, Section: B, page: 4327.
500
$a
Adviser: Anthony J. Borgerding.
502
$a
Thesis (Ph.D.)--The University of North Dakota, 2003.
520
$a
The Pulsed Discharge Helium Ionization Detector (PDHID) was compared to the Flame Ionization Detector (FID) and the Thermal Conductivity Detector (TCD) for High Speed Gas Chromatography (HSGC). It was shown that the PDHID is as sensitive as the FID but can be less reproducible. Moreover, the PDHID is more sensitive and more universal than the TCD. The prospect of a portable PDHID was explored but, a required helium purifier uses more power than is feasible for portability. The PDHID was used to detect hydrogen and methane separated from the matrix components of breath samples with over an order of magnitude better sensitivity than methods using an FID or TCD. Limits of detection for dissolved hydrogen and methane using the Rapid Aqueous Sample Extractor (RASE)-GC-PDHID were 7.0 ng/mL and 3.5 ng/mL respectively.
520
$a
The speciation of selenium compounds from high selenium broccoli (900 mug/g) depends on the extraction conditions. Twenty-seven extraction conditions were explored involving nine different buffering systems between pH 1 and pH 9. In non-buffered extractions of broccoli more than 40% of the spiked Se-methylselenocysteine was not recovered in the filtered solution. However, in buffered extractions losses for Se-methylselenocysteine ranged from 10--20%. Approximately 30% of selenium from broccoli was lost to the atmosphere from buffered extractions. High Pressure Liquid Chromatography coupled to an Inductively Coupled Plasma Mass Spectrometer (HPLC-ICP-MS) for speciating selenium. Changes in speciation were analyte, pH and buffer dependent, but generally higher pH resulted in more highly oxidized selenium compounds.
520
$a
Partition coefficients for selenium compounds across a small intestine model, the CACO-2 cell monolayer, are presented. Selenium compounds were transformed as they passed across the barrier. Presented are tables of the ratios and masses of compounds expected on the basolateral side of the CACO-2 cell model for selenium standards and popular high selenium foods that have undergone simulated digestions.
520
$a
Determination of chiro-inositol and the related fagopyritols in Buckwheat are presented for crops grown in two different years as well as the difference between cooked and uncooked samples. 2,2-dimethoxypropane (2,2-DMP) was shown to be a useful drying agent while trimethylsilylimidazole (TMSI) can be used to derivatize inostiols without pyridine.
590
$a
School code: 0156.
650
4
$a
Engineering, Environmental.
$3
783782
650
4
$a
Chemistry, Analytical.
$3
586156
650
4
$a
Chemistry, Agricultural.
$3
1021829
650
4
$a
Environmental Sciences.
$3
676987
690
$a
0775
690
$a
0486
690
$a
0749
690
$a
0768
710
2 0
$a
The University of North Dakota.
$3
1019287
773
0
$t
Dissertation Abstracts International
$g
64-09B.
790
1 0
$a
Borgerding, Anthony J.,
$e
advisor
790
$a
0156
791
$a
Ph.D.
792
$a
2003
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3107191
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9184992
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入